{"title":"使用产科真空吸引器造成颅顶骨折导致新生儿死亡的罕见病例及文献综述。","authors":"Fiorella Caputo, Isabella Caristo, Rosario Barranco, Luca Vallega Bernucci, Flaminia Torielli, Francesco Ventura","doi":"10.1097/PAF.0000000000000996","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>In the course of childbirth, if complications arise during the expulsion of the fetus, instruments can be employed to facilitate delivery. The vacuum extractor, or ventouse, is considered a relatively safe tool associated with a low rate of complications and mortality. However, it is crucial that the instrument be applied in the correct position and that the pulling force is not excessive to minimize damage to the fetal cranial structures. Fractures of the cranial vault following the application of obstetric vacuum extraction are very rare events.This paper presents a case of perinatal death due to cranial vault fracture and subgaleal hematoma following vacuum extractor application. Only through postmortem examination was it possible to identify incorrect positioning of the ventouse, which was lateralized compared to the recommended position. The misplacement of the device led to an imbalance of forces, causing the cranial vault fracture that led to the infant's demise.A thorough postmortem examination is essential in cases of perinatal death resulting from operative delivery to ascertain the cause of death and reconstruct the dynamics of events during childbirth. In particular, the examination of injuries on the decedent neonate may reveal improper positioning of the instrument.</p>","PeriodicalId":55535,"journal":{"name":"American Journal of Forensic Medicine and Pathology","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Rare Case of Neonatal Death Due to a Cranial Vault Fracture Following the Use of Obstetric Vacuum Extractor and Review of Literature.\",\"authors\":\"Fiorella Caputo, Isabella Caristo, Rosario Barranco, Luca Vallega Bernucci, Flaminia Torielli, Francesco Ventura\",\"doi\":\"10.1097/PAF.0000000000000996\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Abstract: </strong>In the course of childbirth, if complications arise during the expulsion of the fetus, instruments can be employed to facilitate delivery. The vacuum extractor, or ventouse, is considered a relatively safe tool associated with a low rate of complications and mortality. However, it is crucial that the instrument be applied in the correct position and that the pulling force is not excessive to minimize damage to the fetal cranial structures. Fractures of the cranial vault following the application of obstetric vacuum extraction are very rare events.This paper presents a case of perinatal death due to cranial vault fracture and subgaleal hematoma following vacuum extractor application. Only through postmortem examination was it possible to identify incorrect positioning of the ventouse, which was lateralized compared to the recommended position. The misplacement of the device led to an imbalance of forces, causing the cranial vault fracture that led to the infant's demise.A thorough postmortem examination is essential in cases of perinatal death resulting from operative delivery to ascertain the cause of death and reconstruct the dynamics of events during childbirth. In particular, the examination of injuries on the decedent neonate may reveal improper positioning of the instrument.</p>\",\"PeriodicalId\":55535,\"journal\":{\"name\":\"American Journal of Forensic Medicine and Pathology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-11-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Forensic Medicine and Pathology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/PAF.0000000000000996\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, LEGAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Forensic Medicine and Pathology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/PAF.0000000000000996","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, LEGAL","Score":null,"Total":0}
A Rare Case of Neonatal Death Due to a Cranial Vault Fracture Following the Use of Obstetric Vacuum Extractor and Review of Literature.
Abstract: In the course of childbirth, if complications arise during the expulsion of the fetus, instruments can be employed to facilitate delivery. The vacuum extractor, or ventouse, is considered a relatively safe tool associated with a low rate of complications and mortality. However, it is crucial that the instrument be applied in the correct position and that the pulling force is not excessive to minimize damage to the fetal cranial structures. Fractures of the cranial vault following the application of obstetric vacuum extraction are very rare events.This paper presents a case of perinatal death due to cranial vault fracture and subgaleal hematoma following vacuum extractor application. Only through postmortem examination was it possible to identify incorrect positioning of the ventouse, which was lateralized compared to the recommended position. The misplacement of the device led to an imbalance of forces, causing the cranial vault fracture that led to the infant's demise.A thorough postmortem examination is essential in cases of perinatal death resulting from operative delivery to ascertain the cause of death and reconstruct the dynamics of events during childbirth. In particular, the examination of injuries on the decedent neonate may reveal improper positioning of the instrument.
期刊介绍:
Drawing on the expertise of leading forensic pathologists, lawyers, and criminologists, The American Journal of Forensic Medicine and Pathology presents up-to-date coverage of forensic medical practices worldwide. Each issue of the journal features original articles on new examination and documentation procedures.
While most articles are available as web based articles, PDF and in ePub reader format, some earlier articles do not have PDFs available. If you would like to view an article in the ePub format, you will need to download an ePub reader to view this file, a number of which are available for free online.