{"title":"使用产科真空吸引器造成颅顶骨折导致新生儿死亡的罕见病例及文献综述。","authors":"Fiorella Caputo, Isabella Caristo, Rosario Barranco, Luca Vallega Bernucci, Flaminia Torielli, Francesco Ventura","doi":"10.1097/PAF.0000000000000996","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>In the course of childbirth, if complications arise during the expulsion of the fetus, instruments can be employed to facilitate delivery. The vacuum extractor, or ventouse, is considered a relatively safe tool associated with a low rate of complications and mortality. However, it is crucial that the instrument be applied in the correct position and that the pulling force is not excessive to minimize damage to the fetal cranial structures. Fractures of the cranial vault following the application of obstetric vacuum extraction are very rare events.This paper presents a case of perinatal death due to cranial vault fracture and subgaleal hematoma following vacuum extractor application. Only through postmortem examination was it possible to identify incorrect positioning of the ventouse, which was lateralized compared to the recommended position. The misplacement of the device led to an imbalance of forces, causing the cranial vault fracture that led to the infant's demise.A thorough postmortem examination is essential in cases of perinatal death resulting from operative delivery to ascertain the cause of death and reconstruct the dynamics of events during childbirth. In particular, the examination of injuries on the decedent neonate may reveal improper positioning of the instrument.</p>","PeriodicalId":55535,"journal":{"name":"American Journal of Forensic Medicine and Pathology","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Rare Case of Neonatal Death Due to a Cranial Vault Fracture Following the Use of Obstetric Vacuum Extractor and Review of Literature.\",\"authors\":\"Fiorella Caputo, Isabella Caristo, Rosario Barranco, Luca Vallega Bernucci, Flaminia Torielli, Francesco Ventura\",\"doi\":\"10.1097/PAF.0000000000000996\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Abstract: </strong>In the course of childbirth, if complications arise during the expulsion of the fetus, instruments can be employed to facilitate delivery. The vacuum extractor, or ventouse, is considered a relatively safe tool associated with a low rate of complications and mortality. However, it is crucial that the instrument be applied in the correct position and that the pulling force is not excessive to minimize damage to the fetal cranial structures. Fractures of the cranial vault following the application of obstetric vacuum extraction are very rare events.This paper presents a case of perinatal death due to cranial vault fracture and subgaleal hematoma following vacuum extractor application. Only through postmortem examination was it possible to identify incorrect positioning of the ventouse, which was lateralized compared to the recommended position. The misplacement of the device led to an imbalance of forces, causing the cranial vault fracture that led to the infant's demise.A thorough postmortem examination is essential in cases of perinatal death resulting from operative delivery to ascertain the cause of death and reconstruct the dynamics of events during childbirth. In particular, the examination of injuries on the decedent neonate may reveal improper positioning of the instrument.</p>\",\"PeriodicalId\":55535,\"journal\":{\"name\":\"American Journal of Forensic Medicine and Pathology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-11-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Forensic Medicine and Pathology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/PAF.0000000000000996\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, LEGAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Forensic Medicine and Pathology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/PAF.0000000000000996","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, LEGAL","Score":null,"Total":0}
引用次数: 0

摘要

摘要:在分娩过程中,如果在胎儿排出过程中出现并发症,可以使用器械促进分娩。真空吸引器或排气罩被认为是一种相对安全的工具,并发症和死亡率较低。然而,至关重要的是,必须在正确的位置使用器械,而且拉力不能过大,以尽量减少对胎儿颅骨结构的损伤。本文介绍了一例围产期死亡病例,原因是使用真空吸引器后出现颅顶骨折和气管下血肿。只有通过尸检才有可能发现排气阀的位置不正确,与推荐位置相比,排气阀偏向一侧。在手术分娩导致围产期死亡的病例中,彻底的尸检对于确定死亡原因和重建分娩过程中的动态变化至关重要。特别是,对新生儿伤痕的检查可能会发现器械位置不当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Rare Case of Neonatal Death Due to a Cranial Vault Fracture Following the Use of Obstetric Vacuum Extractor and Review of Literature.

Abstract: In the course of childbirth, if complications arise during the expulsion of the fetus, instruments can be employed to facilitate delivery. The vacuum extractor, or ventouse, is considered a relatively safe tool associated with a low rate of complications and mortality. However, it is crucial that the instrument be applied in the correct position and that the pulling force is not excessive to minimize damage to the fetal cranial structures. Fractures of the cranial vault following the application of obstetric vacuum extraction are very rare events.This paper presents a case of perinatal death due to cranial vault fracture and subgaleal hematoma following vacuum extractor application. Only through postmortem examination was it possible to identify incorrect positioning of the ventouse, which was lateralized compared to the recommended position. The misplacement of the device led to an imbalance of forces, causing the cranial vault fracture that led to the infant's demise.A thorough postmortem examination is essential in cases of perinatal death resulting from operative delivery to ascertain the cause of death and reconstruct the dynamics of events during childbirth. In particular, the examination of injuries on the decedent neonate may reveal improper positioning of the instrument.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
103
审稿时长
4-8 weeks
期刊介绍: Drawing on the expertise of leading forensic pathologists, lawyers, and criminologists, The American Journal of Forensic Medicine and Pathology presents up-to-date coverage of forensic medical practices worldwide. Each issue of the journal features original articles on new examination and documentation procedures. While most articles are available as web based articles, PDF and in ePub reader format, some earlier articles do not have PDFs available. If you would like to view an article in the ePub format, you will need to download an ePub reader to view this file, a number of which are available for free online.
期刊最新文献
AJFMP 2024 Reviewer Thank You. Cardiac Myxoma With Postmortem Computed Tomography and Postmortem Examination Correlation. Association Between Cardiovascular Disease and Death by Anaphylaxis: A 20-Year Retrospective Study in Queensland, Australia. Caseous Calcification of the Mitral Annulus: Calcified Toothpaste of the Heart. MDMB-4en-PINACA-Related Deaths in Cook County Jail: Awareness and Preventive Measures.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1