乳腺原位导管癌对比增强超声的图像特征和诊断价值:初步发现。

IF 2.5 4区 医学 Q1 ACOUSTICS Ultrasonic Imaging Pub Date : 2024-11-06 DOI:10.1177/01617346241292032
Weiwei Li, Yingyan Zhao, Xiaochun Fei, Ying Wu, Weiwei Zhan, Wei Zhou, Shujun Xia, Yanyan Song, Jianqiao Zhou
{"title":"乳腺原位导管癌对比增强超声的图像特征和诊断价值:初步发现。","authors":"Weiwei Li, Yingyan Zhao, Xiaochun Fei, Ying Wu, Weiwei Zhan, Wei Zhou, Shujun Xia, Yanyan Song, Jianqiao Zhou","doi":"10.1177/01617346241292032","DOIUrl":null,"url":null,"abstract":"<p><p>To explore the image features and the diagnostic value of contrast-enhanced ultrasound (CEUS) for ductal carcinoma in situ (DCIS) of the breast. A total of 96 female patients with a solitary and histologically proven DCIS were analyzed retrospectively, and 100 female cases of invasive ductal carcinoma (IDC) lesions were used as the control group. The Breast Imaging Reporting and Data System (BI-RADS) category of breast lesions was assessed according to conventional ultrasound features. The DCIS lesions were classified into mass type and non-mass type. The CEUS characteristics of these breast lesions were retrospectively analyzed qualitatively and quantitatively. The final gold standard was biopsy or surgery with histo-pathological examination. Comparing the ultrasound images of DCIS with that of IDC, there were significant differences in echo pattern, calcification morphology, and calcification distribution (<i>p</i> < .05 for all). There was a significant difference between DCIS and IDC in enhancement intensity, perfusion defects, peripheral high enhancement, intratumoral vessels, and arrival time (AT) (<i>p</i> < .05 for all). In the logistic multivariate regression analysis, two indicators linked with DCIS were recognized: perfusion defects (<i>p</i> = .002) and peripheral high enhancement (<i>p</i> < .001). In forecasting DCIS, the logistic regression equation resulted in an AUC of 0.689, a specificity of 0.720, and a sensitivity of 0.563. CEUS showed differences in enhancement characteristics between DCIS and IDC, with perfusion defects and peripheral high enhancement being associated with DCIS.</p>","PeriodicalId":49401,"journal":{"name":"Ultrasonic Imaging","volume":" ","pages":"1617346241292032"},"PeriodicalIF":2.5000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Image Features and Diagnostic Value of Contrast-Enhanced Ultrasound for Ductal Carcinoma In Situ of the Breast: Preliminary Findings.\",\"authors\":\"Weiwei Li, Yingyan Zhao, Xiaochun Fei, Ying Wu, Weiwei Zhan, Wei Zhou, Shujun Xia, Yanyan Song, Jianqiao Zhou\",\"doi\":\"10.1177/01617346241292032\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>To explore the image features and the diagnostic value of contrast-enhanced ultrasound (CEUS) for ductal carcinoma in situ (DCIS) of the breast. A total of 96 female patients with a solitary and histologically proven DCIS were analyzed retrospectively, and 100 female cases of invasive ductal carcinoma (IDC) lesions were used as the control group. The Breast Imaging Reporting and Data System (BI-RADS) category of breast lesions was assessed according to conventional ultrasound features. The DCIS lesions were classified into mass type and non-mass type. The CEUS characteristics of these breast lesions were retrospectively analyzed qualitatively and quantitatively. The final gold standard was biopsy or surgery with histo-pathological examination. Comparing the ultrasound images of DCIS with that of IDC, there were significant differences in echo pattern, calcification morphology, and calcification distribution (<i>p</i> < .05 for all). There was a significant difference between DCIS and IDC in enhancement intensity, perfusion defects, peripheral high enhancement, intratumoral vessels, and arrival time (AT) (<i>p</i> < .05 for all). In the logistic multivariate regression analysis, two indicators linked with DCIS were recognized: perfusion defects (<i>p</i> = .002) and peripheral high enhancement (<i>p</i> < .001). In forecasting DCIS, the logistic regression equation resulted in an AUC of 0.689, a specificity of 0.720, and a sensitivity of 0.563. CEUS showed differences in enhancement characteristics between DCIS and IDC, with perfusion defects and peripheral high enhancement being associated with DCIS.</p>\",\"PeriodicalId\":49401,\"journal\":{\"name\":\"Ultrasonic Imaging\",\"volume\":\" \",\"pages\":\"1617346241292032\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasonic Imaging\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/01617346241292032\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonic Imaging","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/01617346241292032","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨对比增强超声(CEUS)对乳腺导管原位癌(DCIS)的图像特征和诊断价值。回顾性分析了96例经组织学证实的单发乳腺导管原位癌(DCIS)女性患者,并以100例浸润性导管癌(IDC)女性病例作为对照组。根据常规超声特征评估乳腺病变的乳腺影像报告和数据系统(BI-RADS)类别。DCIS病变分为肿块型和非肿块型。对这些乳腺病变的 CEUS 特征进行了回顾性定性和定量分析。最终的金标准是活组织检查或组织病理学检查手术。比较 DCIS 与 IDC 的超声图像,两者在回声模式、钙化形态和钙化分布(p p p = .002)以及周围高增强(p p = .003)方面存在显著差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Image Features and Diagnostic Value of Contrast-Enhanced Ultrasound for Ductal Carcinoma In Situ of the Breast: Preliminary Findings.

To explore the image features and the diagnostic value of contrast-enhanced ultrasound (CEUS) for ductal carcinoma in situ (DCIS) of the breast. A total of 96 female patients with a solitary and histologically proven DCIS were analyzed retrospectively, and 100 female cases of invasive ductal carcinoma (IDC) lesions were used as the control group. The Breast Imaging Reporting and Data System (BI-RADS) category of breast lesions was assessed according to conventional ultrasound features. The DCIS lesions were classified into mass type and non-mass type. The CEUS characteristics of these breast lesions were retrospectively analyzed qualitatively and quantitatively. The final gold standard was biopsy or surgery with histo-pathological examination. Comparing the ultrasound images of DCIS with that of IDC, there were significant differences in echo pattern, calcification morphology, and calcification distribution (p < .05 for all). There was a significant difference between DCIS and IDC in enhancement intensity, perfusion defects, peripheral high enhancement, intratumoral vessels, and arrival time (AT) (p < .05 for all). In the logistic multivariate regression analysis, two indicators linked with DCIS were recognized: perfusion defects (p = .002) and peripheral high enhancement (p < .001). In forecasting DCIS, the logistic regression equation resulted in an AUC of 0.689, a specificity of 0.720, and a sensitivity of 0.563. CEUS showed differences in enhancement characteristics between DCIS and IDC, with perfusion defects and peripheral high enhancement being associated with DCIS.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ultrasonic Imaging
Ultrasonic Imaging 医学-工程:生物医学
CiteScore
5.10
自引率
8.70%
发文量
15
审稿时长
>12 weeks
期刊介绍: Ultrasonic Imaging provides rapid publication for original and exceptional papers concerned with the development and application of ultrasonic-imaging technology. Ultrasonic Imaging publishes articles in the following areas: theoretical and experimental aspects of advanced methods and instrumentation for imaging
期刊最新文献
Image Features and Diagnostic Value of Contrast-Enhanced Ultrasound for Ductal Carcinoma In Situ of the Breast: Preliminary Findings. Ultrasonic Imaging of Deeper Bone Defect Using Virtual Source Synthetic Aperture with Phased Shift Migration: A Phantom Study. Predictive Value of the Nomogram Model Based on Multimodal Ultrasound Features for Benign and Malignant Thyroid Nodules of C-TIRADS Category 4. High Frequency Ultrasound Transducer Based on Sm-Doped Pb(Mg1/3Nb2/3)O3-0.28PbTiO3 Ceramic for Intravascular Ultrasound Imaging. Development and Assessment of a Predictive Model for Ki-67 Expression Using Ultrasound Indicators and Non-Morphological Magnetic Resonance Imaging Parameters Before Breast Cancer Therapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1