为风力存储系统提供可变垂降增益频率支持控制,实现转子动能最大化利用

IF 5 2区 工程技术 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC International Journal of Electrical Power & Energy Systems Pub Date : 2024-11-06 DOI:10.1016/j.ijepes.2024.110289
Wenbo Li , Yujun Li , Jiapeng Li , Yang Zhang , Xiqiang Chang , Zhongqing Sun
{"title":"为风力存储系统提供可变垂降增益频率支持控制,实现转子动能最大化利用","authors":"Wenbo Li ,&nbsp;Yujun Li ,&nbsp;Jiapeng Li ,&nbsp;Yang Zhang ,&nbsp;Xiqiang Chang ,&nbsp;Zhongqing Sun","doi":"10.1016/j.ijepes.2024.110289","DOIUrl":null,"url":null,"abstract":"<div><div>To address the emerging frequency stability issue brought by the large replacement of synchronous generators with renewable generations, wind turbine generators are required to possess frequency-supporting capability. However, existing frequency-supporting control strategies lack the assessment of the frequency support capability of wind turbine generators, leading to degraded control performance under various situations. Aiming to solve this problem, this paper proposes a variable-droop-gain control for wind turbine generators with maximum rotor kinetic energy utilization. Firstly, an analytical relationship was established between droop gain, disturbance scale, and rotor speed. Subsequently, the released energy of the wind turbine generator is evaluated, which equals the difference in the rotor kinetic energy under the initial and the post-disturbance steady-state rotor speed. It was proved that the released kinetic energy cannot exceed a certain proportion of total rotor kinetic energy. Accordingly, a variable initial gain scheme is proposed, which determines the initial droop gain as per the disturbance scale for maximizing the kinetic energy release of wind turbines. Moreover, an additional real-time droop gain adjustment rule is added to prevent the over-deceleration of wind turbines. The simulation results show that the proposed scheme may provide the maximum KE release and effectively improve the system frequency nadir while ensuring the safe operation of wind turbine generators.</div></div>","PeriodicalId":50326,"journal":{"name":"International Journal of Electrical Power & Energy Systems","volume":"163 ","pages":"Article 110289"},"PeriodicalIF":5.0000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Variable droop gain frequency supporting control with maximum rotor kinetic energy utilization for wind-storage system\",\"authors\":\"Wenbo Li ,&nbsp;Yujun Li ,&nbsp;Jiapeng Li ,&nbsp;Yang Zhang ,&nbsp;Xiqiang Chang ,&nbsp;Zhongqing Sun\",\"doi\":\"10.1016/j.ijepes.2024.110289\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>To address the emerging frequency stability issue brought by the large replacement of synchronous generators with renewable generations, wind turbine generators are required to possess frequency-supporting capability. However, existing frequency-supporting control strategies lack the assessment of the frequency support capability of wind turbine generators, leading to degraded control performance under various situations. Aiming to solve this problem, this paper proposes a variable-droop-gain control for wind turbine generators with maximum rotor kinetic energy utilization. Firstly, an analytical relationship was established between droop gain, disturbance scale, and rotor speed. Subsequently, the released energy of the wind turbine generator is evaluated, which equals the difference in the rotor kinetic energy under the initial and the post-disturbance steady-state rotor speed. It was proved that the released kinetic energy cannot exceed a certain proportion of total rotor kinetic energy. Accordingly, a variable initial gain scheme is proposed, which determines the initial droop gain as per the disturbance scale for maximizing the kinetic energy release of wind turbines. Moreover, an additional real-time droop gain adjustment rule is added to prevent the over-deceleration of wind turbines. The simulation results show that the proposed scheme may provide the maximum KE release and effectively improve the system frequency nadir while ensuring the safe operation of wind turbine generators.</div></div>\",\"PeriodicalId\":50326,\"journal\":{\"name\":\"International Journal of Electrical Power & Energy Systems\",\"volume\":\"163 \",\"pages\":\"Article 110289\"},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2024-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Electrical Power & Energy Systems\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0142061524005118\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Electrical Power & Energy Systems","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0142061524005118","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

为解决可再生能源大量替代同步发电机带来的频率稳定问题,要求风力涡轮发电机具备频率支持能力。然而,现有的频率支持控制策略缺乏对风力发电机频率支持能力的评估,导致在各种情况下控制性能下降。为了解决这一问题,本文提出了转子动能利用最大化的风力涡轮发电机变垂增益控制。首先,建立了下垂增益、干扰尺度和转子速度之间的分析关系。随后,对风力发电机的释放能量进行了评估,释放能量等于初始和扰动后稳态转子速度下转子动能的差值。实践证明,释放动能不能超过转子总动能的一定比例。因此,提出了一种可变初始增益方案,根据扰动尺度确定初始垂降增益,以最大限度地释放风力发电机的动能。此外,还增加了一个额外的实时下垂增益调整规则,以防止风机过度减速。仿真结果表明,所提出的方案可提供最大的动能释放,并在确保风力发电机安全运行的同时有效改善系统频率低点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Variable droop gain frequency supporting control with maximum rotor kinetic energy utilization for wind-storage system
To address the emerging frequency stability issue brought by the large replacement of synchronous generators with renewable generations, wind turbine generators are required to possess frequency-supporting capability. However, existing frequency-supporting control strategies lack the assessment of the frequency support capability of wind turbine generators, leading to degraded control performance under various situations. Aiming to solve this problem, this paper proposes a variable-droop-gain control for wind turbine generators with maximum rotor kinetic energy utilization. Firstly, an analytical relationship was established between droop gain, disturbance scale, and rotor speed. Subsequently, the released energy of the wind turbine generator is evaluated, which equals the difference in the rotor kinetic energy under the initial and the post-disturbance steady-state rotor speed. It was proved that the released kinetic energy cannot exceed a certain proportion of total rotor kinetic energy. Accordingly, a variable initial gain scheme is proposed, which determines the initial droop gain as per the disturbance scale for maximizing the kinetic energy release of wind turbines. Moreover, an additional real-time droop gain adjustment rule is added to prevent the over-deceleration of wind turbines. The simulation results show that the proposed scheme may provide the maximum KE release and effectively improve the system frequency nadir while ensuring the safe operation of wind turbine generators.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Electrical Power & Energy Systems
International Journal of Electrical Power & Energy Systems 工程技术-工程:电子与电气
CiteScore
12.10
自引率
17.30%
发文量
1022
审稿时长
51 days
期刊介绍: The journal covers theoretical developments in electrical power and energy systems and their applications. The coverage embraces: generation and network planning; reliability; long and short term operation; expert systems; neural networks; object oriented systems; system control centres; database and information systems; stock and parameter estimation; system security and adequacy; network theory, modelling and computation; small and large system dynamics; dynamic model identification; on-line control including load and switching control; protection; distribution systems; energy economics; impact of non-conventional systems; and man-machine interfaces. As well as original research papers, the journal publishes short contributions, book reviews and conference reports. All papers are peer-reviewed by at least two referees.
期刊最新文献
Microgrid energy management strategy considering source-load forecast error A dimension-enhanced residual multi-scale attention framework for identifying anomalous waveforms of fault recorders Grid structure optimization using slow coherency theory and holomorphic embedding method Two-stage multi-objective optimal dispatch of hybrid power generation system for ramp stress mitigation A fast, simple and local protection scheme for fault detection and classification during power swings based on differential current component
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1