克服长期连续监测土壤二氧化碳通量的障碍:低成本传感器系统

IF 5.8 2区 农林科学 Q1 SOIL SCIENCE Soil Pub Date : 2024-11-07 DOI:10.5194/egusphere-2024-3156
Thi Thuc Nguyen, Nadav Bekin, Ariel Altman, Martin Maier, Nurit Agam, Elad Levintal
{"title":"克服长期连续监测土壤二氧化碳通量的障碍:低成本传感器系统","authors":"Thi Thuc Nguyen, Nadav Bekin, Ariel Altman, Martin Maier, Nurit Agam, Elad Levintal","doi":"10.5194/egusphere-2024-3156","DOIUrl":null,"url":null,"abstract":"<strong>Abstract.</strong> Soil CO<sub>2</sub> flux (<em>F<sub>s</sub></em>) is a carbon cycling metric crucial for assessing ecosystem carbon budgets and global warming. However, global <em>F<sub>s</sub></em> datasets often suffer from low temporal-spatial resolution, as well as from spatial bias. <em>F<sub>s</sub></em> observations are severely deficient in tundra and dryland ecosystems due to financial and logistical constraints of current methods for <em>F<sub>s</sub></em> quantification. In this study, we introduce a novel, low-cost sensor system (LC-SS) for long-term, continuous monitoring of soil CO<sub>2</sub> concentration and flux. The LC-SS, built from affordable, open-source hardware and software, offers a cost-effective solution (~USD700), accessible to low-budget users, and opens the scope for research with a large number of sensor system replications. The LC-SS was tested over ~6 months in arid soil conditions, where fluxes are small, and accuracy is critical. CO<sub>2</sub> concentration and soil temperature were measured at 10-min intervals at depths of 5 and 10 cm. The LC-SS demonstrated high stability and minimal maintenance requirements during the tested period. Both diurnal and seasonal soil CO<sub>2</sub> concentration variabilities were observed, highlighting the system's capability of continuous, long-term, in-situ monitoring of soil CO<sub>2</sub> concentration. In addition, <em>F<sub>s</sub></em> was calculated using the measured CO<sub>2</sub> concentration via the gradient method and validated with <em>F<sub>s</sub></em> measured by the flux chamber method using the well-accepted LI-COR gas analyzer system. Gradient method <em>F<sub>s </sub></em>was in good agreement with flux chamber <em>F<sub>s</sub></em>, highlighting the potential for alternative or concurrent use of the LC-SS with current methods for <em>F<sub>s</sub></em> estimation. Leveraging the accuracy and cost-effectiveness of the LC-SS (below 10 % of automated gas analyzer system cost), strategic implementation of LC-SSs could be a promising means to effectively increase the number of measurements, spatially and temporally, ultimately aiding in bridging the gap between global <em>F<sub>s</sub></em> uncertainties and current measurement limitations.","PeriodicalId":48610,"journal":{"name":"Soil","volume":"25 1","pages":""},"PeriodicalIF":5.8000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Overcoming barriers in long-term, continuous monitoring of soil CO2 flux: A low-cost sensor system\",\"authors\":\"Thi Thuc Nguyen, Nadav Bekin, Ariel Altman, Martin Maier, Nurit Agam, Elad Levintal\",\"doi\":\"10.5194/egusphere-2024-3156\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<strong>Abstract.</strong> Soil CO<sub>2</sub> flux (<em>F<sub>s</sub></em>) is a carbon cycling metric crucial for assessing ecosystem carbon budgets and global warming. However, global <em>F<sub>s</sub></em> datasets often suffer from low temporal-spatial resolution, as well as from spatial bias. <em>F<sub>s</sub></em> observations are severely deficient in tundra and dryland ecosystems due to financial and logistical constraints of current methods for <em>F<sub>s</sub></em> quantification. In this study, we introduce a novel, low-cost sensor system (LC-SS) for long-term, continuous monitoring of soil CO<sub>2</sub> concentration and flux. The LC-SS, built from affordable, open-source hardware and software, offers a cost-effective solution (~USD700), accessible to low-budget users, and opens the scope for research with a large number of sensor system replications. The LC-SS was tested over ~6 months in arid soil conditions, where fluxes are small, and accuracy is critical. CO<sub>2</sub> concentration and soil temperature were measured at 10-min intervals at depths of 5 and 10 cm. The LC-SS demonstrated high stability and minimal maintenance requirements during the tested period. Both diurnal and seasonal soil CO<sub>2</sub> concentration variabilities were observed, highlighting the system's capability of continuous, long-term, in-situ monitoring of soil CO<sub>2</sub> concentration. In addition, <em>F<sub>s</sub></em> was calculated using the measured CO<sub>2</sub> concentration via the gradient method and validated with <em>F<sub>s</sub></em> measured by the flux chamber method using the well-accepted LI-COR gas analyzer system. Gradient method <em>F<sub>s </sub></em>was in good agreement with flux chamber <em>F<sub>s</sub></em>, highlighting the potential for alternative or concurrent use of the LC-SS with current methods for <em>F<sub>s</sub></em> estimation. Leveraging the accuracy and cost-effectiveness of the LC-SS (below 10 % of automated gas analyzer system cost), strategic implementation of LC-SSs could be a promising means to effectively increase the number of measurements, spatially and temporally, ultimately aiding in bridging the gap between global <em>F<sub>s</sub></em> uncertainties and current measurement limitations.\",\"PeriodicalId\":48610,\"journal\":{\"name\":\"Soil\",\"volume\":\"25 1\",\"pages\":\"\"},\"PeriodicalIF\":5.8000,\"publicationDate\":\"2024-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Soil\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.5194/egusphere-2024-3156\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"SOIL SCIENCE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Soil","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.5194/egusphere-2024-3156","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SOIL SCIENCE","Score":null,"Total":0}
引用次数: 0

摘要

摘要。土壤二氧化碳通量(Fs)是一种碳循环指标,对评估生态系统碳预算和全球变暖至关重要。然而,全球 Fs 数据集往往存在时空分辨率低和空间偏差的问题。由于目前的 Fs 定量方法在资金和后勤方面的限制,冻原和旱地生态系统的 Fs 观测严重不足。在本研究中,我们介绍了一种新型低成本传感器系统(LC-SS),用于长期、连续监测土壤二氧化碳浓度和通量。LC-SS 由经济实惠的开源硬件和软件构建而成,提供了一种经济高效的解决方案(约 700 美元),低预算用户也可使用,并为大量传感器系统复制的研究开辟了空间。LC-SS 在干旱的土壤条件下进行了长达约 6 个月的测试,在这种条件下,通量很小,精度至关重要。在 5 厘米和 10 厘米深的土壤中,每隔 10 分钟测量一次二氧化碳浓度和土壤温度。LC-SS 在测试期间表现出很高的稳定性和最低的维护要求。观测到了土壤二氧化碳浓度的昼夜变化和季节变化,突出显示了该系统对土壤二氧化碳浓度进行连续、长期、原位监测的能力。此外,还利用梯度法测量的二氧化碳浓度计算了 Fs,并与使用广受认可的 LI-COR 气体分析仪系统通过通量室法测量的 Fs 进行了验证。梯度法 Fs 与通量室法 Fs 非常一致,凸显了 LC-SS 与当前 Fs 估算方法的替代或并用潜力。利用 LC-SS 的准确性和成本效益(低于自动气体分析仪系统成本的 10%),战略性地实施 LC-SS 可以有效地增加空间和时间上的测量次数,最终帮助缩小全球 Fs 不确定性与当前测量局限性之间的差距。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Overcoming barriers in long-term, continuous monitoring of soil CO2 flux: A low-cost sensor system
Abstract. Soil CO2 flux (Fs) is a carbon cycling metric crucial for assessing ecosystem carbon budgets and global warming. However, global Fs datasets often suffer from low temporal-spatial resolution, as well as from spatial bias. Fs observations are severely deficient in tundra and dryland ecosystems due to financial and logistical constraints of current methods for Fs quantification. In this study, we introduce a novel, low-cost sensor system (LC-SS) for long-term, continuous monitoring of soil CO2 concentration and flux. The LC-SS, built from affordable, open-source hardware and software, offers a cost-effective solution (~USD700), accessible to low-budget users, and opens the scope for research with a large number of sensor system replications. The LC-SS was tested over ~6 months in arid soil conditions, where fluxes are small, and accuracy is critical. CO2 concentration and soil temperature were measured at 10-min intervals at depths of 5 and 10 cm. The LC-SS demonstrated high stability and minimal maintenance requirements during the tested period. Both diurnal and seasonal soil CO2 concentration variabilities were observed, highlighting the system's capability of continuous, long-term, in-situ monitoring of soil CO2 concentration. In addition, Fs was calculated using the measured CO2 concentration via the gradient method and validated with Fs measured by the flux chamber method using the well-accepted LI-COR gas analyzer system. Gradient method Fs was in good agreement with flux chamber Fs, highlighting the potential for alternative or concurrent use of the LC-SS with current methods for Fs estimation. Leveraging the accuracy and cost-effectiveness of the LC-SS (below 10 % of automated gas analyzer system cost), strategic implementation of LC-SSs could be a promising means to effectively increase the number of measurements, spatially and temporally, ultimately aiding in bridging the gap between global Fs uncertainties and current measurement limitations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Soil
Soil Agricultural and Biological Sciences-Soil Science
CiteScore
10.80
自引率
2.90%
发文量
44
审稿时长
30 weeks
期刊介绍: SOIL is an international scientific journal dedicated to the publication and discussion of high-quality research in the field of soil system sciences. SOIL is at the interface between the atmosphere, lithosphere, hydrosphere, and biosphere. SOIL publishes scientific research that contributes to understanding the soil system and its interaction with humans and the entire Earth system. The scope of the journal includes all topics that fall within the study of soil science as a discipline, with an emphasis on studies that integrate soil science with other sciences (hydrology, agronomy, socio-economics, health sciences, atmospheric sciences, etc.).
期刊最新文献
Portable X-Ray Fluorescence as a Tool for Urban Soil Contamination Analysis: Accuracy, Precision, and Practicality Soil organic matter interactions along the elevation gradient of the James Ross Island (Antarctica) Investigating the complementarity of thermal and physical soil organic carbon fractions Overcoming barriers in long-term, continuous monitoring of soil CO2 flux: A low-cost sensor system Exploring the link between cation exchange capacity and magnetic susceptibility
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1