Rebecca Crowder, Balamugesh Thangakunam, Alfred Andama, Devasahayam J Christopher, Victoria Dalay, Welile Nwamba, Sandra V Kik, Dong Van Nguyen, Nguyen Viet Nhung, Patrick P J Phillips, Morten Ruhwald, Grant Theron, William Worodria, Charles Yu, Payam Nahid, Adithya Cattamanchi, Ankur Gupta-Wright, Claudia M Denkinger
{"title":"前瞻性多国队列中结核病筛查试验的诊断准确性:计算机辅助检测的胸部 X 光、Xpert TB 宿主反应和 C 反应蛋白","authors":"Rebecca Crowder, Balamugesh Thangakunam, Alfred Andama, Devasahayam J Christopher, Victoria Dalay, Welile Nwamba, Sandra V Kik, Dong Van Nguyen, Nguyen Viet Nhung, Patrick P J Phillips, Morten Ruhwald, Grant Theron, William Worodria, Charles Yu, Payam Nahid, Adithya Cattamanchi, Ankur Gupta-Wright, Claudia M Denkinger","doi":"10.1093/cid/ciae549","DOIUrl":null,"url":null,"abstract":"Background Accessible, accurate screening tests are necessary to advance tuberculosis (TB) case finding and early detection in high-burden countries. Methods We prospectively screened adults with ≥2 weeks of cough at primary health centers in the Philippines, Vietnam, South Africa, Uganda, and India. Participants received chest-X-ray, Cepheid Xpert TB Host Response (Xpert HR) testing, and point-of-care C-reactive protein (CRP) testing (Boditech). Chest-X-ray images were processed using CAD4TB v7, a computer-aided detection algorithm. We assessed diagnostic accuracy against a microbiologic reference standard (sputum Xpert Ultra, culture). Optimal cut-points were chosen to maximize specificity at 90% sensitivity. Two-test screening algorithms were considered, using 1) sequential negative serial screening (positive defined as positive on either test) and 2) sequential positive serial screening (positive defined as positive on both tests). Results Between July 2021 and August 2022, 1,392 participants with presumptive TB had valid index tests and reference standard results, and 303 (22%) had confirmed TB. In head-to-head comparisons, CAD4TB v7 showed the highest specificity at 90% sensitivity (70.3% vs. 65.1% for Xpert HR, difference 95% CI 1.6 to 8.9; 49.7% for CRP, difference 95% CI 17.0 to 24.3). Three two-test screening algorithms met WHO target product profile (TPP) minimum accuracy thresholds and had higher accuracy than any test alone. At 90% sensitivity, the specificity was 79.6% for Xpert HR-CAD4TB [sequential negative], 75.9% for CRP-CAD4TB [sequential negative], and 73.7% for Xpert HR-CAD4TB [sequential positive]. Conclusions CAD4TB achieves TPP targets and outperforms Xpert HR and CRP. Combining screening tests further increased accuracy. Registration NCT04923958","PeriodicalId":10463,"journal":{"name":"Clinical Infectious Diseases","volume":"9 1","pages":""},"PeriodicalIF":8.2000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostic accuracy of TB screening tests in a prospective multinational cohort: Chest-X-ray with computer-aided detection, Xpert TB host response, and C-reactive protein\",\"authors\":\"Rebecca Crowder, Balamugesh Thangakunam, Alfred Andama, Devasahayam J Christopher, Victoria Dalay, Welile Nwamba, Sandra V Kik, Dong Van Nguyen, Nguyen Viet Nhung, Patrick P J Phillips, Morten Ruhwald, Grant Theron, William Worodria, Charles Yu, Payam Nahid, Adithya Cattamanchi, Ankur Gupta-Wright, Claudia M Denkinger\",\"doi\":\"10.1093/cid/ciae549\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background Accessible, accurate screening tests are necessary to advance tuberculosis (TB) case finding and early detection in high-burden countries. Methods We prospectively screened adults with ≥2 weeks of cough at primary health centers in the Philippines, Vietnam, South Africa, Uganda, and India. Participants received chest-X-ray, Cepheid Xpert TB Host Response (Xpert HR) testing, and point-of-care C-reactive protein (CRP) testing (Boditech). Chest-X-ray images were processed using CAD4TB v7, a computer-aided detection algorithm. We assessed diagnostic accuracy against a microbiologic reference standard (sputum Xpert Ultra, culture). Optimal cut-points were chosen to maximize specificity at 90% sensitivity. Two-test screening algorithms were considered, using 1) sequential negative serial screening (positive defined as positive on either test) and 2) sequential positive serial screening (positive defined as positive on both tests). Results Between July 2021 and August 2022, 1,392 participants with presumptive TB had valid index tests and reference standard results, and 303 (22%) had confirmed TB. In head-to-head comparisons, CAD4TB v7 showed the highest specificity at 90% sensitivity (70.3% vs. 65.1% for Xpert HR, difference 95% CI 1.6 to 8.9; 49.7% for CRP, difference 95% CI 17.0 to 24.3). Three two-test screening algorithms met WHO target product profile (TPP) minimum accuracy thresholds and had higher accuracy than any test alone. At 90% sensitivity, the specificity was 79.6% for Xpert HR-CAD4TB [sequential negative], 75.9% for CRP-CAD4TB [sequential negative], and 73.7% for Xpert HR-CAD4TB [sequential positive]. Conclusions CAD4TB achieves TPP targets and outperforms Xpert HR and CRP. Combining screening tests further increased accuracy. Registration NCT04923958\",\"PeriodicalId\":10463,\"journal\":{\"name\":\"Clinical Infectious Diseases\",\"volume\":\"9 1\",\"pages\":\"\"},\"PeriodicalIF\":8.2000,\"publicationDate\":\"2024-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Infectious Diseases\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/cid/ciae549\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"IMMUNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Infectious Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/cid/ciae549","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
Diagnostic accuracy of TB screening tests in a prospective multinational cohort: Chest-X-ray with computer-aided detection, Xpert TB host response, and C-reactive protein
Background Accessible, accurate screening tests are necessary to advance tuberculosis (TB) case finding and early detection in high-burden countries. Methods We prospectively screened adults with ≥2 weeks of cough at primary health centers in the Philippines, Vietnam, South Africa, Uganda, and India. Participants received chest-X-ray, Cepheid Xpert TB Host Response (Xpert HR) testing, and point-of-care C-reactive protein (CRP) testing (Boditech). Chest-X-ray images were processed using CAD4TB v7, a computer-aided detection algorithm. We assessed diagnostic accuracy against a microbiologic reference standard (sputum Xpert Ultra, culture). Optimal cut-points were chosen to maximize specificity at 90% sensitivity. Two-test screening algorithms were considered, using 1) sequential negative serial screening (positive defined as positive on either test) and 2) sequential positive serial screening (positive defined as positive on both tests). Results Between July 2021 and August 2022, 1,392 participants with presumptive TB had valid index tests and reference standard results, and 303 (22%) had confirmed TB. In head-to-head comparisons, CAD4TB v7 showed the highest specificity at 90% sensitivity (70.3% vs. 65.1% for Xpert HR, difference 95% CI 1.6 to 8.9; 49.7% for CRP, difference 95% CI 17.0 to 24.3). Three two-test screening algorithms met WHO target product profile (TPP) minimum accuracy thresholds and had higher accuracy than any test alone. At 90% sensitivity, the specificity was 79.6% for Xpert HR-CAD4TB [sequential negative], 75.9% for CRP-CAD4TB [sequential negative], and 73.7% for Xpert HR-CAD4TB [sequential positive]. Conclusions CAD4TB achieves TPP targets and outperforms Xpert HR and CRP. Combining screening tests further increased accuracy. Registration NCT04923958
期刊介绍:
Clinical Infectious Diseases (CID) is dedicated to publishing original research, reviews, guidelines, and perspectives with the potential to reshape clinical practice, providing clinicians with valuable insights for patient care. CID comprehensively addresses the clinical presentation, diagnosis, treatment, and prevention of a wide spectrum of infectious diseases. The journal places a high priority on the assessment of current and innovative treatments, microbiology, immunology, and policies, ensuring relevance to patient care in its commitment to advancing the field of infectious diseases.