{"title":"采用可切换亲水性溶剂的泡腾片辅助液相微萃取技术,利用高效液相色谱-二极管阵列检测法测定口服液中的皮质醇和睾酮。","authors":"Carolina Silveira Dalanhol, Camila Scheid, Josias Merib","doi":"10.1002/jssc.70022","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>Cortisol and testosterone are important biomarkers for diagnosing complex disorders, including polycystic ovary syndrome and Cushing's syndrome, where symptomatology usually overlaps with other prevalent disorders. This work proposes, for the first time, an analytical method based on a switchable hydrophilicity solvent as an extraction phase for the determination of cortisol and testosterone in oral fluid (OF) by high-performance liquid chromatography with diode-array detection. The optimized extraction conditions consisted of 1000 µL of OF, 100 µL of decanoic acid solution (65 mg/mL), 170 µL of Na<sub>2</sub>CO<sub>3</sub>, 900 µL of H<sub>2</sub>SO<sub>4</sub> and 150 µL of acetonitrile for dilution. The method was validated, and coefficients of determination higher than 0.9926, the limit of detection of 4.55 ng/mL and the limit of quantification of 15.00 ng/mL were obtained. Intra-day precision varied from 5.6% to 11.9%, inter-day precision ranged from 6.1% to 13.5%, and relative recoveries ranged from 98.9% to 104.6% for cortisol, and 89.1% to 103.9% for testosterone. This methodology was successfully applied to five OF samples from volunteers. Moreover, the greenness of this methodology was evaluated based on the sample preparation metric of sustainability achieving a global score of 7.37 which can be considered sustainable.</p>\n </div>","PeriodicalId":17098,"journal":{"name":"Journal of separation science","volume":"47 21","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2024-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effervescent-assisted Liquid-phase Microextraction Employing Switchable Hydrophilicity Solvent for the Determination of Cortisol and Testosterone in Oral Fluid by High-Performance Liquid Chromatography-Diode Array Detection\",\"authors\":\"Carolina Silveira Dalanhol, Camila Scheid, Josias Merib\",\"doi\":\"10.1002/jssc.70022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <p>Cortisol and testosterone are important biomarkers for diagnosing complex disorders, including polycystic ovary syndrome and Cushing's syndrome, where symptomatology usually overlaps with other prevalent disorders. This work proposes, for the first time, an analytical method based on a switchable hydrophilicity solvent as an extraction phase for the determination of cortisol and testosterone in oral fluid (OF) by high-performance liquid chromatography with diode-array detection. The optimized extraction conditions consisted of 1000 µL of OF, 100 µL of decanoic acid solution (65 mg/mL), 170 µL of Na<sub>2</sub>CO<sub>3</sub>, 900 µL of H<sub>2</sub>SO<sub>4</sub> and 150 µL of acetonitrile for dilution. The method was validated, and coefficients of determination higher than 0.9926, the limit of detection of 4.55 ng/mL and the limit of quantification of 15.00 ng/mL were obtained. Intra-day precision varied from 5.6% to 11.9%, inter-day precision ranged from 6.1% to 13.5%, and relative recoveries ranged from 98.9% to 104.6% for cortisol, and 89.1% to 103.9% for testosterone. This methodology was successfully applied to five OF samples from volunteers. Moreover, the greenness of this methodology was evaluated based on the sample preparation metric of sustainability achieving a global score of 7.37 which can be considered sustainable.</p>\\n </div>\",\"PeriodicalId\":17098,\"journal\":{\"name\":\"Journal of separation science\",\"volume\":\"47 21\",\"pages\":\"\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of separation science\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jssc.70022\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of separation science","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jssc.70022","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Effervescent-assisted Liquid-phase Microextraction Employing Switchable Hydrophilicity Solvent for the Determination of Cortisol and Testosterone in Oral Fluid by High-Performance Liquid Chromatography-Diode Array Detection
Cortisol and testosterone are important biomarkers for diagnosing complex disorders, including polycystic ovary syndrome and Cushing's syndrome, where symptomatology usually overlaps with other prevalent disorders. This work proposes, for the first time, an analytical method based on a switchable hydrophilicity solvent as an extraction phase for the determination of cortisol and testosterone in oral fluid (OF) by high-performance liquid chromatography with diode-array detection. The optimized extraction conditions consisted of 1000 µL of OF, 100 µL of decanoic acid solution (65 mg/mL), 170 µL of Na2CO3, 900 µL of H2SO4 and 150 µL of acetonitrile for dilution. The method was validated, and coefficients of determination higher than 0.9926, the limit of detection of 4.55 ng/mL and the limit of quantification of 15.00 ng/mL were obtained. Intra-day precision varied from 5.6% to 11.9%, inter-day precision ranged from 6.1% to 13.5%, and relative recoveries ranged from 98.9% to 104.6% for cortisol, and 89.1% to 103.9% for testosterone. This methodology was successfully applied to five OF samples from volunteers. Moreover, the greenness of this methodology was evaluated based on the sample preparation metric of sustainability achieving a global score of 7.37 which can be considered sustainable.
期刊介绍:
The Journal of Separation Science (JSS) is the most comprehensive source in separation science, since it covers all areas of chromatographic and electrophoretic separation methods in theory and practice, both in the analytical and in the preparative mode, solid phase extraction, sample preparation, and related techniques. Manuscripts on methodological or instrumental developments, including detection aspects, in particular mass spectrometry, as well as on innovative applications will also be published. Manuscripts on hyphenation, automation, and miniaturization are particularly welcome. Pre- and post-separation facets of a total analysis may be covered as well as the underlying logic of the development or application of a method.