不同照明条件对口内扫描准确性的影响。

IF 2.7 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Advanced Prosthodontics Pub Date : 2024-10-01 Epub Date: 2024-10-28 DOI:10.4047/jap.2024.16.5.311
Mehmet Karakuzu, Caner Öztürk, Züleyha Başar Karakuzu, Mustafa Zortuk
{"title":"不同照明条件对口内扫描准确性的影响。","authors":"Mehmet Karakuzu, Caner Öztürk, Züleyha Başar Karakuzu, Mustafa Zortuk","doi":"10.4047/jap.2024.16.5.311","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to investigate the extent to which intraoral scanning are affected by clinical conditions, and whether ambient lighting and different color temperatures have an impact on the accuracy of intraoral scanner, as well as to evaluate scanning time.</p><p><strong>Materials and methods: </strong>Twelve different environments were created using various ambient lighting conditions (0, 500, 1000 and 1500 lux) and color temperatures (white, blue and yellow). A partially edentulous mandibular model with two implants and a three-unit bridge was scanned under each environment until 10 digital models were obtained, and scanning times were recorded using a virtual stopwatch. A 3D analysis was performed on the obtained digital models, and the data were analyzed using a software. The generalized linear model analysis and Tukey multiple comparison test were used to analyse the data (<i>P</i> < .05).</p><p><strong>Results: </strong>The effect of lux, color temperature, and scanning times on RMS data was found to be significant (<i>P</i> < .001). The mean RMS value was the highest in the 0 lux group and the lowest in the 500 lux group. Regarding the color temperature, the highest RMS value was in the white color group and the lowest in the yellow color group. Scanning times were similar among the 0, 500 and 1000 lux groups, with a significant increase in the 1500 lux group.</p><p><strong>Conclusion: </strong>Different ambient lighting conditions and color temperatures have significant effect on the accuracy of intraoral scanning.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":"16 5","pages":"311-318"},"PeriodicalIF":2.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11538891/pdf/","citationCount":"0","resultStr":"{\"title\":\"The effects of different lighting conditions on the accuracy of intraoral scanning.\",\"authors\":\"Mehmet Karakuzu, Caner Öztürk, Züleyha Başar Karakuzu, Mustafa Zortuk\",\"doi\":\"10.4047/jap.2024.16.5.311\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to investigate the extent to which intraoral scanning are affected by clinical conditions, and whether ambient lighting and different color temperatures have an impact on the accuracy of intraoral scanner, as well as to evaluate scanning time.</p><p><strong>Materials and methods: </strong>Twelve different environments were created using various ambient lighting conditions (0, 500, 1000 and 1500 lux) and color temperatures (white, blue and yellow). A partially edentulous mandibular model with two implants and a three-unit bridge was scanned under each environment until 10 digital models were obtained, and scanning times were recorded using a virtual stopwatch. A 3D analysis was performed on the obtained digital models, and the data were analyzed using a software. The generalized linear model analysis and Tukey multiple comparison test were used to analyse the data (<i>P</i> < .05).</p><p><strong>Results: </strong>The effect of lux, color temperature, and scanning times on RMS data was found to be significant (<i>P</i> < .001). The mean RMS value was the highest in the 0 lux group and the lowest in the 500 lux group. Regarding the color temperature, the highest RMS value was in the white color group and the lowest in the yellow color group. Scanning times were similar among the 0, 500 and 1000 lux groups, with a significant increase in the 1500 lux group.</p><p><strong>Conclusion: </strong>Different ambient lighting conditions and color temperatures have significant effect on the accuracy of intraoral scanning.</p>\",\"PeriodicalId\":51291,\"journal\":{\"name\":\"Journal of Advanced Prosthodontics\",\"volume\":\"16 5\",\"pages\":\"311-318\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11538891/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advanced Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4047/jap.2024.16.5.311\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4047/jap.2024.16.5.311","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/28 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在调查口内扫描受临床条件影响的程度,以及环境照明和不同色温是否会影响口内扫描仪的准确性,并评估扫描时间:使用不同的环境照明条件(0、500、1000 和 1500 勒克斯)和色温(白色、蓝色和黄色)创建了 12 个不同的环境。在每种环境下扫描带有两个种植体和一个三单元牙桥的部分缺牙下颌骨模型,直至获得 10 个数字模型,并使用虚拟秒表记录扫描时间。对获得的数字模型进行三维分析,并使用软件对数据进行分析。采用广义线性模型分析和 Tukey 多重比较检验对数据进行分析(P < .05):结果:勒克斯、色温和扫描时间对有效值数据的影响显著(P < .001)。平均有效值在 0 勒克斯组最高,在 500 勒克斯组最低。色温方面,RMS 值最高的是白色组,最低的是黄色组。0、500 和 1000 勒克斯组的扫描时间相似,1500 勒克斯组的扫描时间显著增加:结论:不同的环境照明条件和色温对口内扫描的准确性有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The effects of different lighting conditions on the accuracy of intraoral scanning.

Purpose: This study aimed to investigate the extent to which intraoral scanning are affected by clinical conditions, and whether ambient lighting and different color temperatures have an impact on the accuracy of intraoral scanner, as well as to evaluate scanning time.

Materials and methods: Twelve different environments were created using various ambient lighting conditions (0, 500, 1000 and 1500 lux) and color temperatures (white, blue and yellow). A partially edentulous mandibular model with two implants and a three-unit bridge was scanned under each environment until 10 digital models were obtained, and scanning times were recorded using a virtual stopwatch. A 3D analysis was performed on the obtained digital models, and the data were analyzed using a software. The generalized linear model analysis and Tukey multiple comparison test were used to analyse the data (P < .05).

Results: The effect of lux, color temperature, and scanning times on RMS data was found to be significant (P < .001). The mean RMS value was the highest in the 0 lux group and the lowest in the 500 lux group. Regarding the color temperature, the highest RMS value was in the white color group and the lowest in the yellow color group. Scanning times were similar among the 0, 500 and 1000 lux groups, with a significant increase in the 1500 lux group.

Conclusion: Different ambient lighting conditions and color temperatures have significant effect on the accuracy of intraoral scanning.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Advanced Prosthodontics
Journal of Advanced Prosthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.70
自引率
3.80%
发文量
25
期刊介绍: This journal aims to convey scientific and clinical progress in the field of prosthodontics and its related areas to many dental communities concerned with esthetic and functional restorations, occlusion, implants, prostheses, and biomaterials related to prosthodontics. This journal publishes • Original research data of high scientific merit in the field of diagnosis, function, esthetics and stomatognathic physiology related to prosthodontic rehabilitation, physiology and mechanics of occlusion, mechanical and biologic aspects of prosthodontic materials including dental implants. • Review articles by experts on controversies and new developments in prosthodontics. • Case reports if they provide or document new fundamental knowledge.
期刊最新文献
Effect of reference objects on the accuracy of digital implant impressions in partially edentulous arches. Impact of type and position of abutment connection on microstrain distribution: an in vitro study. Relationships between maxillofacial morphology and oral function on the habitual and non-habitual chewing sides. Success rate of all-ceramic FPDs depending on the time of restoration between 2011 and 2023. The effects of different lighting conditions on the accuracy of intraoral scanning.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1