有角膜矫形史患者的角膜屈光手术注意事项。

IF 2 4区 医学 Q2 OPHTHALMOLOGY Eye & Contact Lens-Science and Clinical Practice Pub Date : 2024-11-07 DOI:10.1097/ICL.0000000000001138
Victoria M Wang, Kayvon A Moin, Phillip C Hoopes, Majid Moshirfar
{"title":"有角膜矫形史患者的角膜屈光手术注意事项。","authors":"Victoria M Wang, Kayvon A Moin, Phillip C Hoopes, Majid Moshirfar","doi":"10.1097/ICL.0000000000001138","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To review the current literature describing corneal changes observed with orthokeratology (ortho-k) use and to formulate preliminary recommendations for these patients seeking corneal refractive surgery.</p><p><strong>Methods: </strong>The literature search was conducted through the PubMed, Scopus, and Ovid databases through June 4, 2024, for articles regarding corneal physiological, tomographic, and biomechanical changes secondary to ortho-k use.</p><p><strong>Results: </strong>Forty-one articles were found describing several changes associated with ortho-k use, including higher corneal staining, central corneal epithelial thinning and midperipheral thickening, increased higher-order aberrations, decreased contrast sensitivity, reduced corneal hysteresis and corneal resistance factor, and alterations in the tear proteome. The majority of these parameters returned to baseline after ortho-k lens discontinuation, with timing potentially dependent on the amount of myopic correction, duration of ortho-k use, and age of lens fitting.</p><p><strong>Conclusions: </strong>Despite the paucity of articles describing prior ortho-k patients undergoing corneal refractive surgery, it is evident that ortho-k use may potentially cause various corneal physiological, tomographic, and biomechanical changes in patients. Therefore, clinicians are advised to serially monitor ortho-k patients' refraction, tomography, pachymetry, and corneal biomechanics until stability is achieved before considering surgery.</p>","PeriodicalId":50457,"journal":{"name":"Eye & Contact Lens-Science and Clinical Practice","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Corneal Refractive Surgery Considerations in Patients With History of Orthokeratology.\",\"authors\":\"Victoria M Wang, Kayvon A Moin, Phillip C Hoopes, Majid Moshirfar\",\"doi\":\"10.1097/ICL.0000000000001138\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To review the current literature describing corneal changes observed with orthokeratology (ortho-k) use and to formulate preliminary recommendations for these patients seeking corneal refractive surgery.</p><p><strong>Methods: </strong>The literature search was conducted through the PubMed, Scopus, and Ovid databases through June 4, 2024, for articles regarding corneal physiological, tomographic, and biomechanical changes secondary to ortho-k use.</p><p><strong>Results: </strong>Forty-one articles were found describing several changes associated with ortho-k use, including higher corneal staining, central corneal epithelial thinning and midperipheral thickening, increased higher-order aberrations, decreased contrast sensitivity, reduced corneal hysteresis and corneal resistance factor, and alterations in the tear proteome. The majority of these parameters returned to baseline after ortho-k lens discontinuation, with timing potentially dependent on the amount of myopic correction, duration of ortho-k use, and age of lens fitting.</p><p><strong>Conclusions: </strong>Despite the paucity of articles describing prior ortho-k patients undergoing corneal refractive surgery, it is evident that ortho-k use may potentially cause various corneal physiological, tomographic, and biomechanical changes in patients. Therefore, clinicians are advised to serially monitor ortho-k patients' refraction, tomography, pachymetry, and corneal biomechanics until stability is achieved before considering surgery.</p>\",\"PeriodicalId\":50457,\"journal\":{\"name\":\"Eye & Contact Lens-Science and Clinical Practice\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye & Contact Lens-Science and Clinical Practice\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/ICL.0000000000001138\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens-Science and Clinical Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000001138","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的回顾描述使用角膜塑形镜(orthokeratology,简称 ortho-k)后角膜变化的现有文献,并为这些寻求角膜屈光手术的患者制定初步建议:方法:通过PubMed、Scopus和Ovid数据库对2024年6月4日之前有关使用角膜矫形器后角膜生理、断层和生物力学变化的文章进行文献检索:结果:结果发现有 41 篇文章描述了与使用角膜矫形器相关的几种变化,包括角膜染色加深、角膜上皮中央变薄和中周增厚、高阶像差增加、对比敏感度降低、角膜滞后和角膜阻力因子降低以及泪液蛋白质组改变。停用角膜矫形镜后,这些参数大多恢复到基线值,恢复时间可能取决于近视矫正量、使用角膜矫形镜的时间和配镜年龄:尽管描述之前接受角膜屈光手术的角膜矫形器患者的文章很少,但显而易见的是,使用角膜矫形器可能会导致患者的角膜生理、断层扫描和生物力学发生各种变化。因此,建议临床医生对角膜矫形术患者的屈光度、断层扫描、角膜厚度和角膜生物力学进行连续监测,直到达到稳定后再考虑手术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Corneal Refractive Surgery Considerations in Patients With History of Orthokeratology.

Objective: To review the current literature describing corneal changes observed with orthokeratology (ortho-k) use and to formulate preliminary recommendations for these patients seeking corneal refractive surgery.

Methods: The literature search was conducted through the PubMed, Scopus, and Ovid databases through June 4, 2024, for articles regarding corneal physiological, tomographic, and biomechanical changes secondary to ortho-k use.

Results: Forty-one articles were found describing several changes associated with ortho-k use, including higher corneal staining, central corneal epithelial thinning and midperipheral thickening, increased higher-order aberrations, decreased contrast sensitivity, reduced corneal hysteresis and corneal resistance factor, and alterations in the tear proteome. The majority of these parameters returned to baseline after ortho-k lens discontinuation, with timing potentially dependent on the amount of myopic correction, duration of ortho-k use, and age of lens fitting.

Conclusions: Despite the paucity of articles describing prior ortho-k patients undergoing corneal refractive surgery, it is evident that ortho-k use may potentially cause various corneal physiological, tomographic, and biomechanical changes in patients. Therefore, clinicians are advised to serially monitor ortho-k patients' refraction, tomography, pachymetry, and corneal biomechanics until stability is achieved before considering surgery.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.50
自引率
4.30%
发文量
150
审稿时长
6-12 weeks
期刊介绍: Eye & Contact Lens: Science and Clinical Practice is the official journal of the Contact Lens Association of Ophthalmologists (CLAO), an international educational association for anterior segment research and clinical practice of interest to ophthalmologists, optometrists, and other vision care providers and researchers. Focusing especially on contact lenses, it also covers dry eye disease, MGD, infections, toxicity of drops and contact lens care solutions, topography, cornea surgery and post-operative care, optics, refractive surgery and corneal stability (eg, UV cross-linking). Peer-reviewed and published six times annually, it is a highly respected scientific journal in its field.
期刊最新文献
Contact Lens Regulation: Where Have We Been, Where are We Going? Corneal Refractive Surgery Considerations in Patients With History of Orthokeratology. Evaluation of Cyanoacrylate Tissue Adhesive Glue Application Outcomes in Corneal Thinning and Perforation. Spotlight on Amniotic Membrane Extract Eye Drops: A Review of the Literature. Corneal Clarity and Tomographic Patterns in Pseudoexfoliation Syndrome: A Severity-Based Investigation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1