Edith Sandström, Pascal Huysmans, Frans Giskes, Paul Laeven, Sebastiaan Van Nuffel, Ron M. A. Heeren and Ian G. M. Anthony*,
{"title":"大面积样品快速质量显微镜的改进","authors":"Edith Sandström, Pascal Huysmans, Frans Giskes, Paul Laeven, Sebastiaan Van Nuffel, Ron M. A. Heeren and Ian G. M. Anthony*, ","doi":"10.1021/acs.analchem.4c0348010.1021/acs.analchem.4c03480","DOIUrl":null,"url":null,"abstract":"<p >Mass spectrometry imaging (MSI) is a technique that analyzes the chemical information and spatial distribution of surface analytes. Most MSI studies are conducted in microprobe mode, in which a mass spectrum is collected for each pixel to create a mass image. Thus, the spatial resolution, sample imaging area, and imaging speed are linked. In this mode, halving the pixel size quadruples the analytical time, which presents a practical limit on the high spatial resolution MSI throughput. Fast mass microscopy (FMM) is, in contrast, a microscope-mode MSI technique that decouples spatial resolution and imaging speed. FMM circumvents the linear-quadratic relationship of pixel size and analytical time, which enables increased imaging size area and the analytical speed achievable. In this study, we implement instrument modifications to the FMM system, including the addition of linear encoders that enable roughly 8.5× faster imaging than was previously achieved, allowing a 42.5 × 26 mm<sup>2</sup> sample area to be imaged at a 1 μm pixel size in <4.5 min. Linear encoders also enable the alignment of multipass images that increase image homogeneity and signal intensity. The applicability of FMM to large area samples has made it important to define the tolerance to height variations of the technique, which was determined to be at least 218 ± 0.03 (<i>n</i> = 3) μm.</p>","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"96 45","pages":"18037–18042 18037–18042"},"PeriodicalIF":6.7000,"publicationDate":"2024-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.acs.org/doi/epdf/10.1021/acs.analchem.4c03480","citationCount":"0","resultStr":"{\"title\":\"Improvements in Fast Mass Microscopy for Large-Area Samples\",\"authors\":\"Edith Sandström, Pascal Huysmans, Frans Giskes, Paul Laeven, Sebastiaan Van Nuffel, Ron M. A. Heeren and Ian G. M. Anthony*, \",\"doi\":\"10.1021/acs.analchem.4c0348010.1021/acs.analchem.4c03480\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Mass spectrometry imaging (MSI) is a technique that analyzes the chemical information and spatial distribution of surface analytes. Most MSI studies are conducted in microprobe mode, in which a mass spectrum is collected for each pixel to create a mass image. Thus, the spatial resolution, sample imaging area, and imaging speed are linked. In this mode, halving the pixel size quadruples the analytical time, which presents a practical limit on the high spatial resolution MSI throughput. Fast mass microscopy (FMM) is, in contrast, a microscope-mode MSI technique that decouples spatial resolution and imaging speed. FMM circumvents the linear-quadratic relationship of pixel size and analytical time, which enables increased imaging size area and the analytical speed achievable. In this study, we implement instrument modifications to the FMM system, including the addition of linear encoders that enable roughly 8.5× faster imaging than was previously achieved, allowing a 42.5 × 26 mm<sup>2</sup> sample area to be imaged at a 1 μm pixel size in <4.5 min. Linear encoders also enable the alignment of multipass images that increase image homogeneity and signal intensity. The applicability of FMM to large area samples has made it important to define the tolerance to height variations of the technique, which was determined to be at least 218 ± 0.03 (<i>n</i> = 3) μm.</p>\",\"PeriodicalId\":27,\"journal\":{\"name\":\"Analytical Chemistry\",\"volume\":\"96 45\",\"pages\":\"18037–18042 18037–18042\"},\"PeriodicalIF\":6.7000,\"publicationDate\":\"2024-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://pubs.acs.org/doi/epdf/10.1021/acs.analchem.4c03480\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.acs.org/doi/10.1021/acs.analchem.4c03480\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acs.analchem.4c03480","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Improvements in Fast Mass Microscopy for Large-Area Samples
Mass spectrometry imaging (MSI) is a technique that analyzes the chemical information and spatial distribution of surface analytes. Most MSI studies are conducted in microprobe mode, in which a mass spectrum is collected for each pixel to create a mass image. Thus, the spatial resolution, sample imaging area, and imaging speed are linked. In this mode, halving the pixel size quadruples the analytical time, which presents a practical limit on the high spatial resolution MSI throughput. Fast mass microscopy (FMM) is, in contrast, a microscope-mode MSI technique that decouples spatial resolution and imaging speed. FMM circumvents the linear-quadratic relationship of pixel size and analytical time, which enables increased imaging size area and the analytical speed achievable. In this study, we implement instrument modifications to the FMM system, including the addition of linear encoders that enable roughly 8.5× faster imaging than was previously achieved, allowing a 42.5 × 26 mm2 sample area to be imaged at a 1 μm pixel size in <4.5 min. Linear encoders also enable the alignment of multipass images that increase image homogeneity and signal intensity. The applicability of FMM to large area samples has made it important to define the tolerance to height variations of the technique, which was determined to be at least 218 ± 0.03 (n = 3) μm.
期刊介绍:
Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.