Yuting Sun, Qingyu Hu, Jiali Zuo, He Wang, Zhendong Guo, Yulan Wang* and Huiru Tang*,
{"title":"肼辅助超高效液相色谱-串联质谱法同时定量测定多种人体基质中的羧酸酯对映体","authors":"Yuting Sun, Qingyu Hu, Jiali Zuo, He Wang, Zhendong Guo, Yulan Wang* and Huiru Tang*, ","doi":"10.1021/acs.analchem.4c0418710.1021/acs.analchem.4c04187","DOIUrl":null,"url":null,"abstract":"<p >Many chiral carboxylic acids with α-amino, α-hydroxyl, and α-methyl groups are concurrently present in mammals establishing unique molecular phenotypes and multiple biological functions, especially host-microbiota symbiotic interactions. Their chirality-resolved simultaneous quantification is essential to reveal the biochemical details of physiology and pathophysiology, though challenging with their low abundances in some biological matrices and difficulty in enantiomer resolution. Here, we developed a method of the chirality-resolved metabolomics with sensitivity-enhanced quantitation via probe-promotion (Met-SeqPro) for analyzing these chiral carboxylic acids. We designed and synthesized a hydrazide-based novel chiral probe, (<i>S</i>)-benzoyl-proline-hydrazide (<i>S</i>BPH), to convert carboxylic acids into amide diastereomers to enhance their retention and chiral resolution on common C<sub>18</sub> columns. Using the <i>d</i><sub>5</sub>-<i>S</i>BPH-labeled enantiomers as internal standards, we then developed an optimized ultrahigh-performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous quantification of 60 enantiomers of 30 chiral carboxylic acids in one run. This enantiomer-resolved method showed excellent sensitivity (LOD < 4 fmol-on-column), linearity (<i>R</i><sup>2</sup> > 0.992), precision (CV < 15%), accuracy (|RE| < 20%), and recovery (80−120%) in multiple biological matrices. With the method, we then quantified 60 chiral carboxylic acids in human urine, plasma, feces, and A549 cells to define their metabolomic phenotypes. This provides basic data for human phenomics and a promising tool for investigating the mammal-microbiome symbiotic interactions.</p>","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"96 45","pages":"18141–18149 18141–18149"},"PeriodicalIF":6.7000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous Quantification of Carboxylate Enantiomers in Multiple Human Matrices with the Hydrazide-Assisted Ultrahigh-Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry\",\"authors\":\"Yuting Sun, Qingyu Hu, Jiali Zuo, He Wang, Zhendong Guo, Yulan Wang* and Huiru Tang*, \",\"doi\":\"10.1021/acs.analchem.4c0418710.1021/acs.analchem.4c04187\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Many chiral carboxylic acids with α-amino, α-hydroxyl, and α-methyl groups are concurrently present in mammals establishing unique molecular phenotypes and multiple biological functions, especially host-microbiota symbiotic interactions. Their chirality-resolved simultaneous quantification is essential to reveal the biochemical details of physiology and pathophysiology, though challenging with their low abundances in some biological matrices and difficulty in enantiomer resolution. Here, we developed a method of the chirality-resolved metabolomics with sensitivity-enhanced quantitation via probe-promotion (Met-SeqPro) for analyzing these chiral carboxylic acids. We designed and synthesized a hydrazide-based novel chiral probe, (<i>S</i>)-benzoyl-proline-hydrazide (<i>S</i>BPH), to convert carboxylic acids into amide diastereomers to enhance their retention and chiral resolution on common C<sub>18</sub> columns. Using the <i>d</i><sub>5</sub>-<i>S</i>BPH-labeled enantiomers as internal standards, we then developed an optimized ultrahigh-performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous quantification of 60 enantiomers of 30 chiral carboxylic acids in one run. This enantiomer-resolved method showed excellent sensitivity (LOD < 4 fmol-on-column), linearity (<i>R</i><sup>2</sup> > 0.992), precision (CV < 15%), accuracy (|RE| < 20%), and recovery (80−120%) in multiple biological matrices. With the method, we then quantified 60 chiral carboxylic acids in human urine, plasma, feces, and A549 cells to define their metabolomic phenotypes. This provides basic data for human phenomics and a promising tool for investigating the mammal-microbiome symbiotic interactions.</p>\",\"PeriodicalId\":27,\"journal\":{\"name\":\"Analytical Chemistry\",\"volume\":\"96 45\",\"pages\":\"18141–18149 18141–18149\"},\"PeriodicalIF\":6.7000,\"publicationDate\":\"2024-10-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.acs.org/doi/10.1021/acs.analchem.4c04187\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acs.analchem.4c04187","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Simultaneous Quantification of Carboxylate Enantiomers in Multiple Human Matrices with the Hydrazide-Assisted Ultrahigh-Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry
Many chiral carboxylic acids with α-amino, α-hydroxyl, and α-methyl groups are concurrently present in mammals establishing unique molecular phenotypes and multiple biological functions, especially host-microbiota symbiotic interactions. Their chirality-resolved simultaneous quantification is essential to reveal the biochemical details of physiology and pathophysiology, though challenging with their low abundances in some biological matrices and difficulty in enantiomer resolution. Here, we developed a method of the chirality-resolved metabolomics with sensitivity-enhanced quantitation via probe-promotion (Met-SeqPro) for analyzing these chiral carboxylic acids. We designed and synthesized a hydrazide-based novel chiral probe, (S)-benzoyl-proline-hydrazide (SBPH), to convert carboxylic acids into amide diastereomers to enhance their retention and chiral resolution on common C18 columns. Using the d5-SBPH-labeled enantiomers as internal standards, we then developed an optimized ultrahigh-performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous quantification of 60 enantiomers of 30 chiral carboxylic acids in one run. This enantiomer-resolved method showed excellent sensitivity (LOD < 4 fmol-on-column), linearity (R2 > 0.992), precision (CV < 15%), accuracy (|RE| < 20%), and recovery (80−120%) in multiple biological matrices. With the method, we then quantified 60 chiral carboxylic acids in human urine, plasma, feces, and A549 cells to define their metabolomic phenotypes. This provides basic data for human phenomics and a promising tool for investigating the mammal-microbiome symbiotic interactions.
期刊介绍:
Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.