使用准分子灯和汞灯在紫外和真空紫外辐照下对硅橡胶的近表面和块体进行改性

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC ACS Applied Electronic Materials Pub Date : 2024-10-31 DOI:10.1021/acsomega.4c0482310.1021/acsomega.4c04823
Christopher Dölle*, Christoph Schmüser, Igor Quiring and Ralph Wilken, 
{"title":"使用准分子灯和汞灯在紫外和真空紫外辐照下对硅橡胶的近表面和块体进行改性","authors":"Christopher Dölle*,&nbsp;Christoph Schmüser,&nbsp;Igor Quiring and Ralph Wilken,&nbsp;","doi":"10.1021/acsomega.4c0482310.1021/acsomega.4c04823","DOIUrl":null,"url":null,"abstract":"<p >The surface properties of silicone rubber can be modified by irradiation with light from the vacuum ultraviolet (VUV) spectral range of less than 200 nm. After VUV-irradiation at 185 nm with a low-pressure mercury (Hg) lamp, a reduction in residual-dust-coverage (PA fibers) of up to 80% was found. At the same time, the long wavelength UV-radiation at 254 nm of the Hg lamp causes a reduction in the optical transmission properties of the silicone bulk. The near-surface and bulk modification of optically highly transparent silicone rubber was analyzed using XPS, ATR, transmission measurements, and investigations into the reduction of the residual-dust-coverage. A comparison was made between a Hg lamp and an excimer lamp at 172 nm. The results provide valuable information for selecting the appropriate irradiation source, depending on the desired spectral range for a given application. The results indicate that excimer lamps should be preferred for optical applications in the UV-spectral range, while Hg lamps are equally suitable for applications in the visible spectral range despite low transmission losses of less than 0.5%. The irradiation dose data were obtained using a ray tracing simulation as part of these investigations to overcome limitations of UV-sensors, such as their accelerated aging and angular dependence.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.acs.org/doi/epdf/10.1021/acsomega.4c04823","citationCount":"0","resultStr":"{\"title\":\"Near-Surfaces and Bulk Modification of Silicone Rubber under UV- and Vacuum UV-Irradiation Using Excimer and Hg Lamps\",\"authors\":\"Christopher Dölle*,&nbsp;Christoph Schmüser,&nbsp;Igor Quiring and Ralph Wilken,&nbsp;\",\"doi\":\"10.1021/acsomega.4c0482310.1021/acsomega.4c04823\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >The surface properties of silicone rubber can be modified by irradiation with light from the vacuum ultraviolet (VUV) spectral range of less than 200 nm. After VUV-irradiation at 185 nm with a low-pressure mercury (Hg) lamp, a reduction in residual-dust-coverage (PA fibers) of up to 80% was found. At the same time, the long wavelength UV-radiation at 254 nm of the Hg lamp causes a reduction in the optical transmission properties of the silicone bulk. The near-surface and bulk modification of optically highly transparent silicone rubber was analyzed using XPS, ATR, transmission measurements, and investigations into the reduction of the residual-dust-coverage. A comparison was made between a Hg lamp and an excimer lamp at 172 nm. The results provide valuable information for selecting the appropriate irradiation source, depending on the desired spectral range for a given application. The results indicate that excimer lamps should be preferred for optical applications in the UV-spectral range, while Hg lamps are equally suitable for applications in the visible spectral range despite low transmission losses of less than 0.5%. The irradiation dose data were obtained using a ray tracing simulation as part of these investigations to overcome limitations of UV-sensors, such as their accelerated aging and angular dependence.</p>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://pubs.acs.org/doi/epdf/10.1021/acsomega.4c04823\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.acs.org/doi/10.1021/acsomega.4c04823\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"92","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acsomega.4c04823","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

硅橡胶的表面特性可以通过小于 200 纳米的真空紫外线(VUV)光谱范围内的光照射来改变。使用低压汞灯在 185 纳米波长处进行紫外线照射后,残留灰尘覆盖率(PA 纤维)降低了 80%。同时,汞灯 254 纳米的长波长紫外线照射也会降低有机硅体的光学透射性能。通过 XPS、ATR、透射率测量以及对残留灰尘覆盖率降低的研究,分析了光学高透明硅橡胶的近表面和主体改性。对汞灯和 172 纳米准分子灯进行了比较。结果为根据特定应用所需的光谱范围选择合适的辐照源提供了宝贵的信息。结果表明,紫外光谱范围内的光学应用应首选准分子灯,而汞灯尽管透射损失小于 0.5%,但同样适用于可见光谱范围内的应用。作为这些研究的一部分,辐照剂量数据是通过光线跟踪模拟获得的,以克服紫外线传感器的局限性,如加速老化和角度依赖性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Near-Surfaces and Bulk Modification of Silicone Rubber under UV- and Vacuum UV-Irradiation Using Excimer and Hg Lamps

The surface properties of silicone rubber can be modified by irradiation with light from the vacuum ultraviolet (VUV) spectral range of less than 200 nm. After VUV-irradiation at 185 nm with a low-pressure mercury (Hg) lamp, a reduction in residual-dust-coverage (PA fibers) of up to 80% was found. At the same time, the long wavelength UV-radiation at 254 nm of the Hg lamp causes a reduction in the optical transmission properties of the silicone bulk. The near-surface and bulk modification of optically highly transparent silicone rubber was analyzed using XPS, ATR, transmission measurements, and investigations into the reduction of the residual-dust-coverage. A comparison was made between a Hg lamp and an excimer lamp at 172 nm. The results provide valuable information for selecting the appropriate irradiation source, depending on the desired spectral range for a given application. The results indicate that excimer lamps should be preferred for optical applications in the UV-spectral range, while Hg lamps are equally suitable for applications in the visible spectral range despite low transmission losses of less than 0.5%. The irradiation dose data were obtained using a ray tracing simulation as part of these investigations to overcome limitations of UV-sensors, such as their accelerated aging and angular dependence.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
期刊最新文献
Vitamin B12: prevention of human beings from lethal diseases and its food application. Current status and obstacles of narrowing yield gaps of four major crops. Cold shock treatment alleviates pitting in sweet cherry fruit by enhancing antioxidant enzymes activity and regulating membrane lipid metabolism. Removal of proteins and lipids affects structure, in vitro digestion and physicochemical properties of rice flour modified by heat-moisture treatment. Investigating the impact of climate variables on the organic honey yield in Turkey using XGBoost machine learning.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1