Kai Yang, Bolong Li, Zhihao Ma, Jiangang Xu, Dong Wang, Zhiheng Zeng, Derek Ho
{"title":"离子选择性迁移率差分放大器:增强水凝胶中的压力诱导电压响应","authors":"Kai Yang, Bolong Li, Zhihao Ma, Jiangang Xu, Dong Wang, Zhiheng Zeng, Derek Ho","doi":"10.1002/anie.202415000","DOIUrl":null,"url":null,"abstract":"<p><p>Piezoionics is an emerging mechanical-electrical energy conversion paradigm that enables self-powered sensing systems for next-generation intelligent wearable electronics. However, there are currently no rational design approaches to enhance the stimulus response of piezoionic devices. Here, we present a strategy using crown ether as ion-selective mobility differential amplifiers for enhancing the pressured-induced voltage response in ionic polyvinyl alcohol (PVA) hydrogels. The crown ether grafted PVA (PVA-CE) hydrogel prototype achieves a 30-fold amplified piezoionic coefficient of 1490 nV Pa-1 within 0 - 1 kPa, compared to 49 nV Pa-1 of the unmodified PVA. The PVA-CE exhibits an ultra-low pressure detection limit of 0.2 Pa with a fast response time of 18.1 ms. Leveraging these properties, we further demonstrate a human somatosensory network analogous PVA-CE piezoionic skin using arrayed pressure sensing. These capabilities hold great promise for emerging healthcare applications such as synthetic biology, soft robotics, and beyond.</p>","PeriodicalId":125,"journal":{"name":"Angewandte Chemie International Edition","volume":" ","pages":"e202415000"},"PeriodicalIF":16.1000,"publicationDate":"2024-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ion-Selective Mobility Differential Amplifier: Enhancing Pressure-Induced Voltage Response in Hydrogels.\",\"authors\":\"Kai Yang, Bolong Li, Zhihao Ma, Jiangang Xu, Dong Wang, Zhiheng Zeng, Derek Ho\",\"doi\":\"10.1002/anie.202415000\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Piezoionics is an emerging mechanical-electrical energy conversion paradigm that enables self-powered sensing systems for next-generation intelligent wearable electronics. However, there are currently no rational design approaches to enhance the stimulus response of piezoionic devices. Here, we present a strategy using crown ether as ion-selective mobility differential amplifiers for enhancing the pressured-induced voltage response in ionic polyvinyl alcohol (PVA) hydrogels. The crown ether grafted PVA (PVA-CE) hydrogel prototype achieves a 30-fold amplified piezoionic coefficient of 1490 nV Pa-1 within 0 - 1 kPa, compared to 49 nV Pa-1 of the unmodified PVA. The PVA-CE exhibits an ultra-low pressure detection limit of 0.2 Pa with a fast response time of 18.1 ms. Leveraging these properties, we further demonstrate a human somatosensory network analogous PVA-CE piezoionic skin using arrayed pressure sensing. These capabilities hold great promise for emerging healthcare applications such as synthetic biology, soft robotics, and beyond.</p>\",\"PeriodicalId\":125,\"journal\":{\"name\":\"Angewandte Chemie International Edition\",\"volume\":\" \",\"pages\":\"e202415000\"},\"PeriodicalIF\":16.1000,\"publicationDate\":\"2024-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Angewandte Chemie International Edition\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1002/anie.202415000\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Angewandte Chemie International Edition","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1002/anie.202415000","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Ion-Selective Mobility Differential Amplifier: Enhancing Pressure-Induced Voltage Response in Hydrogels.
Piezoionics is an emerging mechanical-electrical energy conversion paradigm that enables self-powered sensing systems for next-generation intelligent wearable electronics. However, there are currently no rational design approaches to enhance the stimulus response of piezoionic devices. Here, we present a strategy using crown ether as ion-selective mobility differential amplifiers for enhancing the pressured-induced voltage response in ionic polyvinyl alcohol (PVA) hydrogels. The crown ether grafted PVA (PVA-CE) hydrogel prototype achieves a 30-fold amplified piezoionic coefficient of 1490 nV Pa-1 within 0 - 1 kPa, compared to 49 nV Pa-1 of the unmodified PVA. The PVA-CE exhibits an ultra-low pressure detection limit of 0.2 Pa with a fast response time of 18.1 ms. Leveraging these properties, we further demonstrate a human somatosensory network analogous PVA-CE piezoionic skin using arrayed pressure sensing. These capabilities hold great promise for emerging healthcare applications such as synthetic biology, soft robotics, and beyond.
期刊介绍:
Angewandte Chemie, a journal of the German Chemical Society (GDCh), maintains a leading position among scholarly journals in general chemistry with an impressive Impact Factor of 16.6 (2022 Journal Citation Reports, Clarivate, 2023). Published weekly in a reader-friendly format, it features new articles almost every day. Established in 1887, Angewandte Chemie is a prominent chemistry journal, offering a dynamic blend of Review-type articles, Highlights, Communications, and Research Articles on a weekly basis, making it unique in the field.