Sysmex XN-9000 血液分析仪可为体液中的有核细胞分类和恶性血清积液的检测提供参考。

IF 1.1 4区 医学 Q4 MEDICAL LABORATORY TECHNOLOGY Annals of clinical and laboratory science Pub Date : 2024-09-01
Yabin Chen, Jian Huang, Huidan Chen, Linghui Ma, Min Dou, Qiurong Zhao, Zhishan Zhang, Xiaomei Wen
{"title":"Sysmex XN-9000 血液分析仪可为体液中的有核细胞分类和恶性血清积液的检测提供参考。","authors":"Yabin Chen, Jian Huang, Huidan Chen, Linghui Ma, Min Dou, Qiurong Zhao, Zhishan Zhang, Xiaomei Wen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The purpose of this study is to evaluate the accuracy of Sysmex XN-9000 hematology analyzer (XN-9000) in detecting nucleated cell classifications in serous effusion and to further evaluate whether it can be used for screening malignant serous effusion.</p><p><strong>Methods: </strong>The consistency between XN-9000 and manual microscopy in the classification of nucleated cells was evaluated using Passing-Bablok regression and Bland-Altman plot. ROC analysis was applied to evaluate the value of HF-BF% in screening malignant specimens.</p><p><strong>Results: </strong>In the serous effusion of the group with nucleated cell count of (0-150) ×10<sup>6</sup>/μL, high consistency between XN-9000 and manual microscopy was found in detecting NE-BF% and LY-BF%. In the group with nucleated cell count >150×10<sup>6</sup>/μL, there was high consistency in detecting NE-BF%, LY-BF%, and HF-BF%. ROC analysis showed that HF-BF% can be used for screening malignant serous effusion, with an area under the curve (AUC) of 0.572 (95%CI=0.504~0.639).</p><p><strong>Conclusion: </strong>If XN-9000 detection results are mainly NE-BF% and LY-BF%, the classification can be effectively referred to and reported regardless of the number of nucleated cells in the serous effusion. HF-BF% has certain value in screening malignant serous effusion with a nuclear cell count >150×10<sup>6</sup>/μL. The optimal cut-off value is 13.15%.</p>","PeriodicalId":8228,"journal":{"name":"Annals of clinical and laboratory science","volume":"54 5","pages":"671-678"},"PeriodicalIF":1.1000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sysmex XN-9000 Hematology Analyzer Can Provide Reference for the Classification of Nucleated Cells in Body Fluid and Detect Malignant Serous Effusion.\",\"authors\":\"Yabin Chen, Jian Huang, Huidan Chen, Linghui Ma, Min Dou, Qiurong Zhao, Zhishan Zhang, Xiaomei Wen\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The purpose of this study is to evaluate the accuracy of Sysmex XN-9000 hematology analyzer (XN-9000) in detecting nucleated cell classifications in serous effusion and to further evaluate whether it can be used for screening malignant serous effusion.</p><p><strong>Methods: </strong>The consistency between XN-9000 and manual microscopy in the classification of nucleated cells was evaluated using Passing-Bablok regression and Bland-Altman plot. ROC analysis was applied to evaluate the value of HF-BF% in screening malignant specimens.</p><p><strong>Results: </strong>In the serous effusion of the group with nucleated cell count of (0-150) ×10<sup>6</sup>/μL, high consistency between XN-9000 and manual microscopy was found in detecting NE-BF% and LY-BF%. In the group with nucleated cell count >150×10<sup>6</sup>/μL, there was high consistency in detecting NE-BF%, LY-BF%, and HF-BF%. ROC analysis showed that HF-BF% can be used for screening malignant serous effusion, with an area under the curve (AUC) of 0.572 (95%CI=0.504~0.639).</p><p><strong>Conclusion: </strong>If XN-9000 detection results are mainly NE-BF% and LY-BF%, the classification can be effectively referred to and reported regardless of the number of nucleated cells in the serous effusion. HF-BF% has certain value in screening malignant serous effusion with a nuclear cell count >150×10<sup>6</sup>/μL. The optimal cut-off value is 13.15%.</p>\",\"PeriodicalId\":8228,\"journal\":{\"name\":\"Annals of clinical and laboratory science\",\"volume\":\"54 5\",\"pages\":\"671-678\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of clinical and laboratory science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of clinical and laboratory science","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在评估 Sysmex XN-9000 血液分析仪(XN-9000)检测浆液性渗出液中有核细胞分类的准确性,并进一步评估其是否可用于筛查恶性浆液性渗出液:方法:使用 Passing-Bablok 回归和 Bland-Altman 图评估了 XN-9000 与人工显微镜在有核细胞分类方面的一致性。应用 ROC 分析评估 HF-BF% 在筛查恶性标本中的价值:在有核细胞计数为(0-150)×106/μL组的血清渗出液中,XN-9000和人工显微镜在检测NE-BF%和LY-BF%方面具有高度一致性。在有核细胞计数大于 150×106/μL 的组中,检测 NE-BF%、LY-BF% 和 HF-BF% 的一致性很高。ROC分析表明,HF-BF%可用于筛查恶性浆液性渗出,其曲线下面积(AUC)为0.572(95%CI=0.504~0.639):结论:如果XN-9000的检测结果主要是NE-BF%和LY-BF%,那么无论浆液性渗出物中有多少有核细胞,都能有效地参考和报告其分类。HF-BF%对筛查核细胞数大于150×106/μL的恶性浆液性渗出有一定价值。最佳临界值为 13.15%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Sysmex XN-9000 Hematology Analyzer Can Provide Reference for the Classification of Nucleated Cells in Body Fluid and Detect Malignant Serous Effusion.

Objective: The purpose of this study is to evaluate the accuracy of Sysmex XN-9000 hematology analyzer (XN-9000) in detecting nucleated cell classifications in serous effusion and to further evaluate whether it can be used for screening malignant serous effusion.

Methods: The consistency between XN-9000 and manual microscopy in the classification of nucleated cells was evaluated using Passing-Bablok regression and Bland-Altman plot. ROC analysis was applied to evaluate the value of HF-BF% in screening malignant specimens.

Results: In the serous effusion of the group with nucleated cell count of (0-150) ×106/μL, high consistency between XN-9000 and manual microscopy was found in detecting NE-BF% and LY-BF%. In the group with nucleated cell count >150×106/μL, there was high consistency in detecting NE-BF%, LY-BF%, and HF-BF%. ROC analysis showed that HF-BF% can be used for screening malignant serous effusion, with an area under the curve (AUC) of 0.572 (95%CI=0.504~0.639).

Conclusion: If XN-9000 detection results are mainly NE-BF% and LY-BF%, the classification can be effectively referred to and reported regardless of the number of nucleated cells in the serous effusion. HF-BF% has certain value in screening malignant serous effusion with a nuclear cell count >150×106/μL. The optimal cut-off value is 13.15%.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Annals of clinical and laboratory science
Annals of clinical and laboratory science 医学-医学实验技术
CiteScore
1.60
自引率
0.00%
发文量
112
审稿时长
6-12 weeks
期刊介绍: The Annals of Clinical & Laboratory Science welcomes manuscripts that report research in clinical science, including pathology, clinical chemistry, biotechnology, molecular biology, cytogenetics, microbiology, immunology, hematology, transfusion medicine, organ and tissue transplantation, therapeutics, toxicology, and clinical informatics.
期刊最新文献
Communication: 4-Hydroxynonenal and Fracture Risk in the Community-Dwelling Older People. Letter to the Editor. Evaluation of Swab: Direct Extraction Kit, Comparing with AdvanSure E3 System for Nucleic Acid Extraction in Identification of SARS-CoV-2. A Case of Hb Phnom Penh Showing Different HbA1c Levels Depending on the High-Performance Liquid Chromatography System. Application of IdyllaTM System for Rapid Evaluation of EGFR Mutation Status in Formalin-Fixed and Paraffin-Embedded Samples of Non-Small Cell Lung Cancer. Biomarkers Identification of Early Rheumatoid Arthritis via Bioinformatics Approach and Experimental Verification.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1