Kexin Wang , Zheng Zhao , Yi Liu , Rile Nai , Changwei Yuan , Pengsheng Wu , Jialun Li , Xiaodong Zhang , He Wang
{"title":"输尿管长度测量:基于深度学习的方法与 CT 和 KUB 上的其他估算方法的比较。","authors":"Kexin Wang , Zheng Zhao , Yi Liu , Rile Nai , Changwei Yuan , Pengsheng Wu , Jialun Li , Xiaodong Zhang , He Wang","doi":"10.1016/j.compbiomed.2024.109374","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Accurate preoperative assessment of ureteral length is crucial for effective ureteral stenting.</div></div><div><h3>Purpose</h3><div>Utilize a deep learning approach to measure ureter length on CT urography (CTU) images and compare the obtained results with those derived from other estimation methods.</div></div><div><h3>Methods</h3><div>In a retrospective cohort (cohort A, n = 411), CTU images were collected and used to develop a 3D deep learning model for the segmentation of bilateral ureters. The centerline of the ureters was determined based on the segmentation, and the length of the ureters was automatically obtained (CTU_ai). Another cohort (cohort B, n = 220) was collected as the hold-out test for the model. All patients in cohort B had KUB, non-contrast enhanced CT (CT NoC), and CTU images. Cohort B utilized eight measurement methods, with one annotated by two radiologists serving as the reference standard (CTU_ref) and the remaining seven as the studied methods, including three measurement methods applied to CTU (CTU_ai, CTU_oblique, CTU_slice), two applied to CT NoC (CT_oblique, CT_slice), and two applied to KUB (KUB_short, KUB_long). The results of the seven studied methods were compared to those of the reference in cohort B.</div></div><div><h3>Results</h3><div>Among the 220 patients (96 females, 124 males), 437 ureters were measured for length (218 left, 219 right), with a median length of 24.7 (IQR 23.2–26.2) cm. No significant differences were observed between genders or laterality (both <em>P</em> > 0.05). Moreover, there was no correlation between ureteral length and age (r = −0.027, <em>P</em> = 0.573). The ureteral length measured by CTU_ai was not significantly different from that measured by CTU_ref (<em>P</em> = 0.514), whereas the length measured by the other studied methods was significantly different from that measured by CTU_ref (all <em>P</em> < 0.001). The ICC values with their 95 % confidence intervals (CIs) for the comparison between the reference standard (CTU_ref) and the other measurement methods: CTU_ai (ICC = 0.852, 95 % CI 0.825–0.876), CTU_oblique (ICC = 0.351, 95 % CI -0.083-0.689), CTU_slice (ICC = 0.269, 95 % CI -0.095-0.573), CTU_oblique_slice (ICC = 0.059, 95 % CI -0.032-0.218), CTU_slice (ICC = 0.049, 95 % CI -0.028-0.188), KUB_short (ICC = 0.151, 95 % CI 0.051–0.247), and KUB_long (ICC = 0.147, 95 % CI 0.034–0.253). For CTU_ai, in 89.0 % of the ureters, the ureteral length deviation was within 20 mm of the reference standard, which was the highest among all the studied methods (all <em>P</em> < 0.001).</div></div><div><h3>Conclusion</h3><div>The deep learning model offers a reliable and accurate tool for ureteral length measurement on CTU images, which could enhance the effectiveness of ureteral stenting procedures. Its performance surpasses traditional measurement methods, making it a promising technology for integration into clinical practice.</div></div>","PeriodicalId":10578,"journal":{"name":"Computers in biology and medicine","volume":"184 ","pages":"Article 109374"},"PeriodicalIF":7.0000,"publicationDate":"2024-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of ureteral length: Comparison of deep learning-based method and other estimation methods on CT and KUB\",\"authors\":\"Kexin Wang , Zheng Zhao , Yi Liu , Rile Nai , Changwei Yuan , Pengsheng Wu , Jialun Li , Xiaodong Zhang , He Wang\",\"doi\":\"10.1016/j.compbiomed.2024.109374\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>Accurate preoperative assessment of ureteral length is crucial for effective ureteral stenting.</div></div><div><h3>Purpose</h3><div>Utilize a deep learning approach to measure ureter length on CT urography (CTU) images and compare the obtained results with those derived from other estimation methods.</div></div><div><h3>Methods</h3><div>In a retrospective cohort (cohort A, n = 411), CTU images were collected and used to develop a 3D deep learning model for the segmentation of bilateral ureters. The centerline of the ureters was determined based on the segmentation, and the length of the ureters was automatically obtained (CTU_ai). Another cohort (cohort B, n = 220) was collected as the hold-out test for the model. All patients in cohort B had KUB, non-contrast enhanced CT (CT NoC), and CTU images. Cohort B utilized eight measurement methods, with one annotated by two radiologists serving as the reference standard (CTU_ref) and the remaining seven as the studied methods, including three measurement methods applied to CTU (CTU_ai, CTU_oblique, CTU_slice), two applied to CT NoC (CT_oblique, CT_slice), and two applied to KUB (KUB_short, KUB_long). The results of the seven studied methods were compared to those of the reference in cohort B.</div></div><div><h3>Results</h3><div>Among the 220 patients (96 females, 124 males), 437 ureters were measured for length (218 left, 219 right), with a median length of 24.7 (IQR 23.2–26.2) cm. No significant differences were observed between genders or laterality (both <em>P</em> > 0.05). Moreover, there was no correlation between ureteral length and age (r = −0.027, <em>P</em> = 0.573). The ureteral length measured by CTU_ai was not significantly different from that measured by CTU_ref (<em>P</em> = 0.514), whereas the length measured by the other studied methods was significantly different from that measured by CTU_ref (all <em>P</em> < 0.001). The ICC values with their 95 % confidence intervals (CIs) for the comparison between the reference standard (CTU_ref) and the other measurement methods: CTU_ai (ICC = 0.852, 95 % CI 0.825–0.876), CTU_oblique (ICC = 0.351, 95 % CI -0.083-0.689), CTU_slice (ICC = 0.269, 95 % CI -0.095-0.573), CTU_oblique_slice (ICC = 0.059, 95 % CI -0.032-0.218), CTU_slice (ICC = 0.049, 95 % CI -0.028-0.188), KUB_short (ICC = 0.151, 95 % CI 0.051–0.247), and KUB_long (ICC = 0.147, 95 % CI 0.034–0.253). For CTU_ai, in 89.0 % of the ureters, the ureteral length deviation was within 20 mm of the reference standard, which was the highest among all the studied methods (all <em>P</em> < 0.001).</div></div><div><h3>Conclusion</h3><div>The deep learning model offers a reliable and accurate tool for ureteral length measurement on CTU images, which could enhance the effectiveness of ureteral stenting procedures. Its performance surpasses traditional measurement methods, making it a promising technology for integration into clinical practice.</div></div>\",\"PeriodicalId\":10578,\"journal\":{\"name\":\"Computers in biology and medicine\",\"volume\":\"184 \",\"pages\":\"Article 109374\"},\"PeriodicalIF\":7.0000,\"publicationDate\":\"2024-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computers in biology and medicine\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0010482524014598\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in biology and medicine","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0010482524014598","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOLOGY","Score":null,"Total":0}
Measurement of ureteral length: Comparison of deep learning-based method and other estimation methods on CT and KUB
Background
Accurate preoperative assessment of ureteral length is crucial for effective ureteral stenting.
Purpose
Utilize a deep learning approach to measure ureter length on CT urography (CTU) images and compare the obtained results with those derived from other estimation methods.
Methods
In a retrospective cohort (cohort A, n = 411), CTU images were collected and used to develop a 3D deep learning model for the segmentation of bilateral ureters. The centerline of the ureters was determined based on the segmentation, and the length of the ureters was automatically obtained (CTU_ai). Another cohort (cohort B, n = 220) was collected as the hold-out test for the model. All patients in cohort B had KUB, non-contrast enhanced CT (CT NoC), and CTU images. Cohort B utilized eight measurement methods, with one annotated by two radiologists serving as the reference standard (CTU_ref) and the remaining seven as the studied methods, including three measurement methods applied to CTU (CTU_ai, CTU_oblique, CTU_slice), two applied to CT NoC (CT_oblique, CT_slice), and two applied to KUB (KUB_short, KUB_long). The results of the seven studied methods were compared to those of the reference in cohort B.
Results
Among the 220 patients (96 females, 124 males), 437 ureters were measured for length (218 left, 219 right), with a median length of 24.7 (IQR 23.2–26.2) cm. No significant differences were observed between genders or laterality (both P > 0.05). Moreover, there was no correlation between ureteral length and age (r = −0.027, P = 0.573). The ureteral length measured by CTU_ai was not significantly different from that measured by CTU_ref (P = 0.514), whereas the length measured by the other studied methods was significantly different from that measured by CTU_ref (all P < 0.001). The ICC values with their 95 % confidence intervals (CIs) for the comparison between the reference standard (CTU_ref) and the other measurement methods: CTU_ai (ICC = 0.852, 95 % CI 0.825–0.876), CTU_oblique (ICC = 0.351, 95 % CI -0.083-0.689), CTU_slice (ICC = 0.269, 95 % CI -0.095-0.573), CTU_oblique_slice (ICC = 0.059, 95 % CI -0.032-0.218), CTU_slice (ICC = 0.049, 95 % CI -0.028-0.188), KUB_short (ICC = 0.151, 95 % CI 0.051–0.247), and KUB_long (ICC = 0.147, 95 % CI 0.034–0.253). For CTU_ai, in 89.0 % of the ureters, the ureteral length deviation was within 20 mm of the reference standard, which was the highest among all the studied methods (all P < 0.001).
Conclusion
The deep learning model offers a reliable and accurate tool for ureteral length measurement on CTU images, which could enhance the effectiveness of ureteral stenting procedures. Its performance surpasses traditional measurement methods, making it a promising technology for integration into clinical practice.
期刊介绍:
Computers in Biology and Medicine is an international forum for sharing groundbreaking advancements in the use of computers in bioscience and medicine. This journal serves as a medium for communicating essential research, instruction, ideas, and information regarding the rapidly evolving field of computer applications in these domains. By encouraging the exchange of knowledge, we aim to facilitate progress and innovation in the utilization of computers in biology and medicine.