{"title":"评估硬皮病相关间质性肺病的 B 线:手持设备的作用","authors":"Codrina Ancuța, Cristina Pomirleanu, Ecaterina Gănceanu, Milena Adina Man, Eugen Ancuta, Paraschiva Postolache","doi":"10.3390/diagnostics14212397","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background</b>: Timely detection and aggressive management of interstitial lung disease (ILD) in systemic sclerosis (SSc) are essential to improving outcomes and reducing risks of irreversible lung injury. <b>Objective</b>: to explore the usefulness of an ultraportable ultrasound device for the management of SSc-related ILD and to compare it with clinical and instrumental data. <b>Methods</b>: A total of 19 consecutive SSc patients underwent a comprehensive pulmonary evaluation: clinical, pulmonary function tests (PFTs) (spirometry, DLCO), lung CT (1.5 mm slice thickness reconstruction; HRCT), and lung ultrasound (LUS). A total score was calculated based on the number of color-coded B-lines recorded for each lung sliding. B-lines were analyzed against dyspnea, cough, Velcro, CT imaging (Warrick's score), and PFTs. Global and subgroup analysis were performed (diffuse versus limited cutaneous SSc, Warrick's < 7 versus >7). <b>Results</b>: Symptomatic lung involvement with varying degrees of dyspnea was reported in about 74% of cases (functional NYHA > 2 in more than half), chronic dry cough in one-third, Velcro rales in 42%. A total of 84.24% were classified as SSc with ILD on CT imaging. Statistically significant mild-to-moderate correlations between B-lines and clinical manifestations were demonstrated, as well as PFTs and Warrick's scores (more B-lines, lower pulmonary function, but higher extent and severity on CT) (<i>p</i> < 0.05); there were differences between SSc patients without and with ILD in terms of the number and distribution of B-lines (<i>p</i> < 0.05), as well as different B-lines patterns and numbers in diffuse versus limited SSc (<i>p</i> < 0.05). <b>Conclusions</b>: Ultraportable handheld LUS is a promising method suitable for the management (screening, early detection, and evaluation) of SSc patients.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"14 21","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11545409/pdf/","citationCount":"0","resultStr":"{\"title\":\"B-Lines in the Assessment of Interstitial Lung Disease Associated with Scleroderma: The Role of Handheld Devices.\",\"authors\":\"Codrina Ancuța, Cristina Pomirleanu, Ecaterina Gănceanu, Milena Adina Man, Eugen Ancuta, Paraschiva Postolache\",\"doi\":\"10.3390/diagnostics14212397\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background</b>: Timely detection and aggressive management of interstitial lung disease (ILD) in systemic sclerosis (SSc) are essential to improving outcomes and reducing risks of irreversible lung injury. <b>Objective</b>: to explore the usefulness of an ultraportable ultrasound device for the management of SSc-related ILD and to compare it with clinical and instrumental data. <b>Methods</b>: A total of 19 consecutive SSc patients underwent a comprehensive pulmonary evaluation: clinical, pulmonary function tests (PFTs) (spirometry, DLCO), lung CT (1.5 mm slice thickness reconstruction; HRCT), and lung ultrasound (LUS). A total score was calculated based on the number of color-coded B-lines recorded for each lung sliding. B-lines were analyzed against dyspnea, cough, Velcro, CT imaging (Warrick's score), and PFTs. Global and subgroup analysis were performed (diffuse versus limited cutaneous SSc, Warrick's < 7 versus >7). <b>Results</b>: Symptomatic lung involvement with varying degrees of dyspnea was reported in about 74% of cases (functional NYHA > 2 in more than half), chronic dry cough in one-third, Velcro rales in 42%. A total of 84.24% were classified as SSc with ILD on CT imaging. Statistically significant mild-to-moderate correlations between B-lines and clinical manifestations were demonstrated, as well as PFTs and Warrick's scores (more B-lines, lower pulmonary function, but higher extent and severity on CT) (<i>p</i> < 0.05); there were differences between SSc patients without and with ILD in terms of the number and distribution of B-lines (<i>p</i> < 0.05), as well as different B-lines patterns and numbers in diffuse versus limited SSc (<i>p</i> < 0.05). <b>Conclusions</b>: Ultraportable handheld LUS is a promising method suitable for the management (screening, early detection, and evaluation) of SSc patients.</p>\",\"PeriodicalId\":11225,\"journal\":{\"name\":\"Diagnostics\",\"volume\":\"14 21\",\"pages\":\"\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11545409/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3390/diagnostics14212397\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics14212397","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
B-Lines in the Assessment of Interstitial Lung Disease Associated with Scleroderma: The Role of Handheld Devices.
Background: Timely detection and aggressive management of interstitial lung disease (ILD) in systemic sclerosis (SSc) are essential to improving outcomes and reducing risks of irreversible lung injury. Objective: to explore the usefulness of an ultraportable ultrasound device for the management of SSc-related ILD and to compare it with clinical and instrumental data. Methods: A total of 19 consecutive SSc patients underwent a comprehensive pulmonary evaluation: clinical, pulmonary function tests (PFTs) (spirometry, DLCO), lung CT (1.5 mm slice thickness reconstruction; HRCT), and lung ultrasound (LUS). A total score was calculated based on the number of color-coded B-lines recorded for each lung sliding. B-lines were analyzed against dyspnea, cough, Velcro, CT imaging (Warrick's score), and PFTs. Global and subgroup analysis were performed (diffuse versus limited cutaneous SSc, Warrick's < 7 versus >7). Results: Symptomatic lung involvement with varying degrees of dyspnea was reported in about 74% of cases (functional NYHA > 2 in more than half), chronic dry cough in one-third, Velcro rales in 42%. A total of 84.24% were classified as SSc with ILD on CT imaging. Statistically significant mild-to-moderate correlations between B-lines and clinical manifestations were demonstrated, as well as PFTs and Warrick's scores (more B-lines, lower pulmonary function, but higher extent and severity on CT) (p < 0.05); there were differences between SSc patients without and with ILD in terms of the number and distribution of B-lines (p < 0.05), as well as different B-lines patterns and numbers in diffuse versus limited SSc (p < 0.05). Conclusions: Ultraportable handheld LUS is a promising method suitable for the management (screening, early detection, and evaluation) of SSc patients.
DiagnosticsBiochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍:
Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.