考虑用于热改性固结的修复复合材料膜厚比较

IF 3.2 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Esthetic and Restorative Dentistry Pub Date : 2024-11-14 DOI:10.1111/jerd.13363
Pascal Magne, Sam Alawie, Michel Magne, Marco Carvalho, Taban Milani
{"title":"考虑用于热改性固结的修复复合材料膜厚比较","authors":"Pascal Magne, Sam Alawie, Michel Magne, Marco Carvalho, Taban Milani","doi":"10.1111/jerd.13363","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study proposes an updated method for the film thickness of 21 resin composites used as cements.</p><p><strong>Materials and methods: </strong>A load of 30 N was subjected to two glass plates stacked on a heated base to simulate clinically relevant pressure and temperature during the seating of inlays/onlays/veneers. The axial position of the actuator was recorded before and after placing 22.15 mm<sup>3</sup> of resin composite between the glass slides. The difference between the two measurements was calculated for each specimen. A total of 18 condensable restoratives, 1 injectable restorative, and 2 resin cements were tested, 5 specimens each (n = 5, N = 105). One-way ANOVA was performed for both variables and Games-Howell post hoc test was used for pairwise comparisons.</p><p><strong>Results: </strong>The film thickness range was 6-200 μm, with the lowest values for restorative composites (AP-X, Z250, and Herculite XRV Incisal LT with 6-8 μm), followed by Gradia Direct (25 μm) and flowable/injectable composite resins, including designated cements (15-27 μm). Inspiro, Ultradent Transcend Universal, and ENA Hri dentin stood below 50 μm (range 28-49 μm). The other materials (range 81-200 μm) cannot be recommended for thermo-modified cementation.</p><p><strong>Conclusions: </strong>The initial viscosity of restorative composites is not an indication of the film thickness when used for thermo-modified cementation. There is a wide choice of appropriate materials available on the market.</p><p><strong>Clinical significance: </strong>Some restorative composites are able to generate very thin films and can be used as cement with numerous advantages when compared to designated flowable or dual-cure cements.</p>","PeriodicalId":15988,"journal":{"name":"Journal of Esthetic and Restorative Dentistry","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2024-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of Film Thickness of Restorative Composites Considered for Thermo-Modified Cementation.\",\"authors\":\"Pascal Magne, Sam Alawie, Michel Magne, Marco Carvalho, Taban Milani\",\"doi\":\"10.1111/jerd.13363\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>This study proposes an updated method for the film thickness of 21 resin composites used as cements.</p><p><strong>Materials and methods: </strong>A load of 30 N was subjected to two glass plates stacked on a heated base to simulate clinically relevant pressure and temperature during the seating of inlays/onlays/veneers. The axial position of the actuator was recorded before and after placing 22.15 mm<sup>3</sup> of resin composite between the glass slides. The difference between the two measurements was calculated for each specimen. A total of 18 condensable restoratives, 1 injectable restorative, and 2 resin cements were tested, 5 specimens each (n = 5, N = 105). One-way ANOVA was performed for both variables and Games-Howell post hoc test was used for pairwise comparisons.</p><p><strong>Results: </strong>The film thickness range was 6-200 μm, with the lowest values for restorative composites (AP-X, Z250, and Herculite XRV Incisal LT with 6-8 μm), followed by Gradia Direct (25 μm) and flowable/injectable composite resins, including designated cements (15-27 μm). Inspiro, Ultradent Transcend Universal, and ENA Hri dentin stood below 50 μm (range 28-49 μm). The other materials (range 81-200 μm) cannot be recommended for thermo-modified cementation.</p><p><strong>Conclusions: </strong>The initial viscosity of restorative composites is not an indication of the film thickness when used for thermo-modified cementation. There is a wide choice of appropriate materials available on the market.</p><p><strong>Clinical significance: </strong>Some restorative composites are able to generate very thin films and can be used as cement with numerous advantages when compared to designated flowable or dual-cure cements.</p>\",\"PeriodicalId\":15988,\"journal\":{\"name\":\"Journal of Esthetic and Restorative Dentistry\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-11-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Esthetic and Restorative Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/jerd.13363\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Esthetic and Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jerd.13363","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究提出了 21 种用作胶结剂的树脂复合材料薄膜厚度的最新方法:本研究提出了一种最新方法,用于测量用作粘结剂的 21 种树脂复合材料的薄膜厚度:在加热底座上叠放的两块玻璃板上施加 30 N 的负荷,以模拟嵌体/高嵌体/窝洞就位时的临床相关压力和温度。在玻璃片之间放置 22.15 mm3 树脂复合材料之前和之后,记录推杆的轴向位置。计算每个试样两次测量值之间的差值。总共测试了 18 种冷凝修复体、1 种注射修复体和 2 种树脂水门汀,每种各 5 个试样(n = 5,N = 105)。对两个变量进行单因素方差分析,并采用 Games-Howell 后检验进行配对比较:薄膜厚度范围为 6-200 μm,修复用复合树脂的薄膜厚度最小(AP-X、Z250 和 Herculite XRV Incisal LT 为 6-8 μm),其次是 Gradia Direct(25 μm)和可流动/可注射复合树脂,包括指定水门汀(15-27 μm)。Inspiro、Ultradent Transcend Universal和ENA Hri牙本质低于50微米(范围28-49微米)。其他材料(范围 81-200μm)不能推荐用于热改性粘接:结论:在用于热改性粘结时,修复复合材料的初始粘度并不能作为薄膜厚度的指标。市场上有多种合适的材料可供选择:临床意义:有些修复复合材料能够生成非常薄的薄膜,与指定的可流动或双固化水门汀相比,用作水门汀具有许多优点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of Film Thickness of Restorative Composites Considered for Thermo-Modified Cementation.

Objective: This study proposes an updated method for the film thickness of 21 resin composites used as cements.

Materials and methods: A load of 30 N was subjected to two glass plates stacked on a heated base to simulate clinically relevant pressure and temperature during the seating of inlays/onlays/veneers. The axial position of the actuator was recorded before and after placing 22.15 mm3 of resin composite between the glass slides. The difference between the two measurements was calculated for each specimen. A total of 18 condensable restoratives, 1 injectable restorative, and 2 resin cements were tested, 5 specimens each (n = 5, N = 105). One-way ANOVA was performed for both variables and Games-Howell post hoc test was used for pairwise comparisons.

Results: The film thickness range was 6-200 μm, with the lowest values for restorative composites (AP-X, Z250, and Herculite XRV Incisal LT with 6-8 μm), followed by Gradia Direct (25 μm) and flowable/injectable composite resins, including designated cements (15-27 μm). Inspiro, Ultradent Transcend Universal, and ENA Hri dentin stood below 50 μm (range 28-49 μm). The other materials (range 81-200 μm) cannot be recommended for thermo-modified cementation.

Conclusions: The initial viscosity of restorative composites is not an indication of the film thickness when used for thermo-modified cementation. There is a wide choice of appropriate materials available on the market.

Clinical significance: Some restorative composites are able to generate very thin films and can be used as cement with numerous advantages when compared to designated flowable or dual-cure cements.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Esthetic and Restorative Dentistry
Journal of Esthetic and Restorative Dentistry 医学-牙科与口腔外科
CiteScore
6.30
自引率
6.20%
发文量
124
审稿时长
>12 weeks
期刊介绍: The Journal of Esthetic and Restorative Dentistry (JERD) is the longest standing peer-reviewed journal devoted solely to advancing the knowledge and practice of esthetic dentistry. Its goal is to provide the very latest evidence-based information in the realm of contemporary interdisciplinary esthetic dentistry through high quality clinical papers, sound research reports and educational features. The range of topics covered in the journal includes: - Interdisciplinary esthetic concepts - Implants - Conservative adhesive restorations - Tooth Whitening - Prosthodontic materials and techniques - Dental materials - Orthodontic, periodontal and endodontic esthetics - Esthetics related research - Innovations in esthetics
期刊最新文献
Introducing a novel approach to dental color reproduction using AI technology. Digital Guides for Precise U-Shaped Splitting and Simultaneous Implant Placement With Minimal Surgical Trauma. Survival and Complications of Partial Coverage Restorations on Posterior Teeth-A Systematic Review and Meta-Analysis. B-Guide System: Improving the Predictability of Complete-Arch Implant and Prosthetic Placement Using Fixed Prosthesis Guides. Advances in Dental Restorations: A Comprehensive Review of Machinable and 3D-Printed Ceramic-Reinforced Composites.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1