小腿肌肉扩散峰度张量参数的重复性。

IF 3 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Magnetic Resonance in Medicine Pub Date : 2024-11-11 DOI:10.1002/mrm.30344
Ethan Mathew, Richard Dortch, Bruce Damon, Sudarshan Ragunathan, C. Chad Quarles
{"title":"小腿肌肉扩散峰度张量参数的重复性。","authors":"Ethan Mathew,&nbsp;Richard Dortch,&nbsp;Bruce Damon,&nbsp;Sudarshan Ragunathan,&nbsp;C. Chad Quarles","doi":"10.1002/mrm.30344","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>The aim of this study was to provide measurements from and investigate the repeatability of diffusion kurtosis tensor parameters in the muscles of the lower legs.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Test–retest acquisition of a kurtosis tensor sequence was performed in 13 healthy volunteers. Quantitative kurtosis tensor parameters were derived, and repeatability of each parameter was evaluated by muscle group and over the whole muscle through intraclass correlation coefficient (ICC) and within-subject coefficient of variation (wsCV). Bland–Altman analysis was also conducted. Differences in parameter values by muscle group were investigated through an analysis of variance.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Axial kurtosis and radial kurtosis values from the test data were 0.63 ± 0.04 and 0.70 ± 0.05, respectively. Kurtosis tensor parameters from all muscle groups and over the whole muscle had wsCV below 15%. ICC for the parameters from most muscle groups was above 85%, with the lowest ICC over the whole muscle being 88.39%. The medial gastrocnemius and extensor digitorum longus showed highest repeatability. Mean, axial, and radial diffusivity had higher wsCV despite being lower-order terms than kurtosis.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>This study sought to examine the repeatability of diffusion kurtosis tensor–derived parameters in the legs and verify that they could potentially be used as longitudinal imaging metrics. wsCV values from test–retest data indicated high repeatability throughout all examined muscle groups. There were minimal differences in kurtosis and diffusivity parameters between muscle groups in this healthy volunteer cohort.</p>\n </section>\n </div>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":"93 3","pages":"1306-1313"},"PeriodicalIF":3.0000,"publicationDate":"2024-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Repeatability of diffusion kurtosis tensor parameters in muscles of the lower legs\",\"authors\":\"Ethan Mathew,&nbsp;Richard Dortch,&nbsp;Bruce Damon,&nbsp;Sudarshan Ragunathan,&nbsp;C. Chad Quarles\",\"doi\":\"10.1002/mrm.30344\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Purpose</h3>\\n \\n <p>The aim of this study was to provide measurements from and investigate the repeatability of diffusion kurtosis tensor parameters in the muscles of the lower legs.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>Test–retest acquisition of a kurtosis tensor sequence was performed in 13 healthy volunteers. Quantitative kurtosis tensor parameters were derived, and repeatability of each parameter was evaluated by muscle group and over the whole muscle through intraclass correlation coefficient (ICC) and within-subject coefficient of variation (wsCV). Bland–Altman analysis was also conducted. Differences in parameter values by muscle group were investigated through an analysis of variance.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Axial kurtosis and radial kurtosis values from the test data were 0.63 ± 0.04 and 0.70 ± 0.05, respectively. Kurtosis tensor parameters from all muscle groups and over the whole muscle had wsCV below 15%. ICC for the parameters from most muscle groups was above 85%, with the lowest ICC over the whole muscle being 88.39%. The medial gastrocnemius and extensor digitorum longus showed highest repeatability. Mean, axial, and radial diffusivity had higher wsCV despite being lower-order terms than kurtosis.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>This study sought to examine the repeatability of diffusion kurtosis tensor–derived parameters in the legs and verify that they could potentially be used as longitudinal imaging metrics. wsCV values from test–retest data indicated high repeatability throughout all examined muscle groups. There were minimal differences in kurtosis and diffusivity parameters between muscle groups in this healthy volunteer cohort.</p>\\n </section>\\n </div>\",\"PeriodicalId\":18065,\"journal\":{\"name\":\"Magnetic Resonance in Medicine\",\"volume\":\"93 3\",\"pages\":\"1306-1313\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic Resonance in Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/mrm.30344\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/mrm.30344","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在对小腿肌肉的扩散峰度张量参数进行测量并研究其重复性:方法:对 13 名健康志愿者进行了峰度张量序列的测试-重测采集。得出峰度张量定量参数,并通过类内相关系数(ICC)和受试者内变异系数(wsCV)评估各参数在肌肉组和整个肌肉中的可重复性。还进行了布兰-阿尔特曼分析。通过方差分析研究了各肌肉组参数值的差异:结果:测试数据的轴向峰度和径向峰度值分别为 0.63 ± 0.04 和 0.70 ± 0.05。所有肌群和整个肌肉的峰度张量参数的 wsCV 均低于 15%。大多数肌群参数的 ICC 均高于 85%,整个肌肉的最低 ICC 为 88.39%。腓肠肌内侧和拇长伸肌的重复性最高。平均弥散度、轴向弥散度和径向弥散度的 wsCV 较高,尽管它们是峰度的低阶项:这项研究旨在检查腿部扩散峰度张量衍生参数的可重复性,并验证它们是否有可能用作纵向成像指标。在这个健康志愿者队列中,不同肌肉组之间的峰度和扩散参数差异极小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Repeatability of diffusion kurtosis tensor parameters in muscles of the lower legs

Purpose

The aim of this study was to provide measurements from and investigate the repeatability of diffusion kurtosis tensor parameters in the muscles of the lower legs.

Methods

Test–retest acquisition of a kurtosis tensor sequence was performed in 13 healthy volunteers. Quantitative kurtosis tensor parameters were derived, and repeatability of each parameter was evaluated by muscle group and over the whole muscle through intraclass correlation coefficient (ICC) and within-subject coefficient of variation (wsCV). Bland–Altman analysis was also conducted. Differences in parameter values by muscle group were investigated through an analysis of variance.

Results

Axial kurtosis and radial kurtosis values from the test data were 0.63 ± 0.04 and 0.70 ± 0.05, respectively. Kurtosis tensor parameters from all muscle groups and over the whole muscle had wsCV below 15%. ICC for the parameters from most muscle groups was above 85%, with the lowest ICC over the whole muscle being 88.39%. The medial gastrocnemius and extensor digitorum longus showed highest repeatability. Mean, axial, and radial diffusivity had higher wsCV despite being lower-order terms than kurtosis.

Conclusion

This study sought to examine the repeatability of diffusion kurtosis tensor–derived parameters in the legs and verify that they could potentially be used as longitudinal imaging metrics. wsCV values from test–retest data indicated high repeatability throughout all examined muscle groups. There were minimal differences in kurtosis and diffusivity parameters between muscle groups in this healthy volunteer cohort.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.70
自引率
24.20%
发文量
376
审稿时长
2-4 weeks
期刊介绍: Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.
期刊最新文献
Considerations and recommendations from the ISMRM diffusion study group for preclinical diffusion MRI: Part 1: In vivo small-animal imaging. Considerations and recommendations from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 3-Ex vivo imaging: Data processing, comparisons with microscopy, and tractography. On the RF safety of titanium mesh head implants in 7 T MRI systems: an investigation. 3D joint T1/T1 ρ/T2 mapping and water-fat imaging for contrast-agent free myocardial tissue characterization at 1.5T. Whole liver phase-based R2 mapping in liver iron overload within a breath-hold.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1