{"title":"尝试通过最先进的网格型参考计算模型--IR-192 辐射源事故案例研究,重新估算非均质辐射事故中受害者的器官剂量。","authors":"Munehiko Kowatari, Hiroshi Yoshitomi, Kotaro Tani, Yoshihiko Tanimura, Osamu Kurihara","doi":"10.1093/rpd/ncae070","DOIUrl":null,"url":null,"abstract":"<p><p>An attempt was made to estimate organ doses of a victim in a high-dose non-homogeneous exposure accident caused by a sealed 192Ir gamma-ray source. The Gilan accident was selected as a case study. Organ doses including testis, red bone marrow and so on were properly estimated by applying the Monte Carlo calculation with the state-of-the-art adult male Mesh type Reference Computational Phantom. By introducing a complicated exposure scenario, the dose distribution on the right chest of the victim in the Gilan accident could be reproduced to a certain extent.</p>","PeriodicalId":20795,"journal":{"name":"Radiation protection dosimetry","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Attempt to re-estimate organ doses of victims in non-homogeneous exposure accident by means of the state-of-the-art Mesh-type Reference Computational Phantom-a case study of an IR-192 source accident.\",\"authors\":\"Munehiko Kowatari, Hiroshi Yoshitomi, Kotaro Tani, Yoshihiko Tanimura, Osamu Kurihara\",\"doi\":\"10.1093/rpd/ncae070\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An attempt was made to estimate organ doses of a victim in a high-dose non-homogeneous exposure accident caused by a sealed 192Ir gamma-ray source. The Gilan accident was selected as a case study. Organ doses including testis, red bone marrow and so on were properly estimated by applying the Monte Carlo calculation with the state-of-the-art adult male Mesh type Reference Computational Phantom. By introducing a complicated exposure scenario, the dose distribution on the right chest of the victim in the Gilan accident could be reproduced to a certain extent.</p>\",\"PeriodicalId\":20795,\"journal\":{\"name\":\"Radiation protection dosimetry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-11-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation protection dosimetry\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1093/rpd/ncae070\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation protection dosimetry","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncae070","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
Attempt to re-estimate organ doses of victims in non-homogeneous exposure accident by means of the state-of-the-art Mesh-type Reference Computational Phantom-a case study of an IR-192 source accident.
An attempt was made to estimate organ doses of a victim in a high-dose non-homogeneous exposure accident caused by a sealed 192Ir gamma-ray source. The Gilan accident was selected as a case study. Organ doses including testis, red bone marrow and so on were properly estimated by applying the Monte Carlo calculation with the state-of-the-art adult male Mesh type Reference Computational Phantom. By introducing a complicated exposure scenario, the dose distribution on the right chest of the victim in the Gilan accident could be reproduced to a certain extent.
期刊介绍:
Radiation Protection Dosimetry covers all aspects of personal and environmental dosimetry and monitoring, for both ionising and non-ionising radiations. This includes biological aspects, physical concepts, biophysical dosimetry, external and internal personal dosimetry and monitoring, environmental and workplace monitoring, accident dosimetry, and dosimetry related to the protection of patients. Particular emphasis is placed on papers covering the fundamentals of dosimetry; units, radiation quantities and conversion factors. Papers covering archaeological dating are included only if the fundamental measurement method or technique, such as thermoluminescence, has direct application to personal dosimetry measurements. Papers covering the dosimetric aspects of radon or other naturally occurring radioactive materials and low level radiation are included. Animal experiments and ecological sample measurements are not included unless there is a significant relevant content reason.