采样面速度对用于环境空气放射性监测的纤维素膜过滤器和纤维素-玻璃纤维过滤器的超细粒子表面收集效率的影响。

IF 0.8 4区 环境科学与生态学 Q4 ENVIRONMENTAL SCIENCES Radiation protection dosimetry Pub Date : 2024-11-13 DOI:10.1093/rpd/ncae191
Mizuki Kiso, Manaya Taoka, Aoi Sampei, Hiroki Hashimoto, Yuki Abe, Yuki Oda, Yasutaka Omori, Ryohei Yamada, Masahiro Hosoda, Chutima Kranrod, Tetsuo Ishikawa, Shinji Tokonami
{"title":"采样面速度对用于环境空气放射性监测的纤维素膜过滤器和纤维素-玻璃纤维过滤器的超细粒子表面收集效率的影响。","authors":"Mizuki Kiso, Manaya Taoka, Aoi Sampei, Hiroki Hashimoto, Yuki Abe, Yuki Oda, Yasutaka Omori, Ryohei Yamada, Masahiro Hosoda, Chutima Kranrod, Tetsuo Ishikawa, Shinji Tokonami","doi":"10.1093/rpd/ncae191","DOIUrl":null,"url":null,"abstract":"<p><p>Surface collection efficiency (SCE) of a cellulose membrane filter (CMF) and a cellulose-glass fiber filter used in environmental monitoring for alpha-emitting radionuclides from nuclear facilities and natural radioactivity sources was evaluated for particles in the size range of 0.03-0.1 μm at different levels of face velocity. The SCE of the CMF was higher than that of the cellulose-glass fiber filter, and only the membrane filter showed the dependence of SCE on the particle size at higher face velocity. The use of the CMF at higher face velocity in environmental radioactivity monitoring leads to measurements of the background alpha spectrum with more degradation under the changing particle size condition in the atmosphere. Consequently, that fact needs to be taken into account, along with the expected particle size distribution and concentration of the airborne radioactivity being sampled, when selecting a face velocity to achieve the best possible detection limit.</p>","PeriodicalId":20795,"journal":{"name":"Radiation protection dosimetry","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11561569/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of sampling face velocity on the ultrafine particle surface collection efficiency of a cellulose membrane filter and a cellulose-glass fiber filter for environmental airborne radioactivity monitoring.\",\"authors\":\"Mizuki Kiso, Manaya Taoka, Aoi Sampei, Hiroki Hashimoto, Yuki Abe, Yuki Oda, Yasutaka Omori, Ryohei Yamada, Masahiro Hosoda, Chutima Kranrod, Tetsuo Ishikawa, Shinji Tokonami\",\"doi\":\"10.1093/rpd/ncae191\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Surface collection efficiency (SCE) of a cellulose membrane filter (CMF) and a cellulose-glass fiber filter used in environmental monitoring for alpha-emitting radionuclides from nuclear facilities and natural radioactivity sources was evaluated for particles in the size range of 0.03-0.1 μm at different levels of face velocity. The SCE of the CMF was higher than that of the cellulose-glass fiber filter, and only the membrane filter showed the dependence of SCE on the particle size at higher face velocity. The use of the CMF at higher face velocity in environmental radioactivity monitoring leads to measurements of the background alpha spectrum with more degradation under the changing particle size condition in the atmosphere. Consequently, that fact needs to be taken into account, along with the expected particle size distribution and concentration of the airborne radioactivity being sampled, when selecting a face velocity to achieve the best possible detection limit.</p>\",\"PeriodicalId\":20795,\"journal\":{\"name\":\"Radiation protection dosimetry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-11-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11561569/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation protection dosimetry\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1093/rpd/ncae191\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation protection dosimetry","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncae191","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

对用于核设施和天然放射源α放射性核素环境监测的纤维素膜过滤器(CMF)和纤维素玻璃纤维过滤器在不同面速下对 0.03-0.1 μm 粒径范围内颗粒的表面收集效率(SCE)进行了评估。CMF的SCE高于纤维素-玻璃纤维过滤器,只有膜过滤器在较高的面速下显示出SCE与颗粒大小的关系。在环境放射性监测中使用较高面速的 CMF 会导致在大气中粒径变化条件下测量的本底α谱衰减更多。因此,在选择面速度以达到最佳检测限时,需要考虑到这一事实,以及预期的粒度分布和采样空气中放射性的浓度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of sampling face velocity on the ultrafine particle surface collection efficiency of a cellulose membrane filter and a cellulose-glass fiber filter for environmental airborne radioactivity monitoring.

Surface collection efficiency (SCE) of a cellulose membrane filter (CMF) and a cellulose-glass fiber filter used in environmental monitoring for alpha-emitting radionuclides from nuclear facilities and natural radioactivity sources was evaluated for particles in the size range of 0.03-0.1 μm at different levels of face velocity. The SCE of the CMF was higher than that of the cellulose-glass fiber filter, and only the membrane filter showed the dependence of SCE on the particle size at higher face velocity. The use of the CMF at higher face velocity in environmental radioactivity monitoring leads to measurements of the background alpha spectrum with more degradation under the changing particle size condition in the atmosphere. Consequently, that fact needs to be taken into account, along with the expected particle size distribution and concentration of the airborne radioactivity being sampled, when selecting a face velocity to achieve the best possible detection limit.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiation protection dosimetry
Radiation protection dosimetry 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
1.40
自引率
10.00%
发文量
223
审稿时长
6-12 weeks
期刊介绍: Radiation Protection Dosimetry covers all aspects of personal and environmental dosimetry and monitoring, for both ionising and non-ionising radiations. This includes biological aspects, physical concepts, biophysical dosimetry, external and internal personal dosimetry and monitoring, environmental and workplace monitoring, accident dosimetry, and dosimetry related to the protection of patients. Particular emphasis is placed on papers covering the fundamentals of dosimetry; units, radiation quantities and conversion factors. Papers covering archaeological dating are included only if the fundamental measurement method or technique, such as thermoluminescence, has direct application to personal dosimetry measurements. Papers covering the dosimetric aspects of radon or other naturally occurring radioactive materials and low level radiation are included. Animal experiments and ecological sample measurements are not included unless there is a significant relevant content reason.
期刊最新文献
A new tool for estimation of the in vivo distribution of intake radionuclides. A summary of updated UNSCEAR evaluations on medical and occupational exposures to ionising radiation and call for participation in UNSCEAR Global Surveys on radiation exposure. A pilot study to directly estimate radiation-induced mutation in large Japanese field mouse duo sample, mother and offspring, excluding unknown father, using ddRAD sequencing. An efficient and simple method for enriching metaphase cells for dicentric chromosome assay. Absorption and translocation to fruit for cesium applied on apple tree leaf surface.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1