利用荧光核轨道探测器评估和优化重离子测量条件。

IF 0.8 4区 环境科学与生态学 Q4 ENVIRONMENTAL SCIENCES Radiation protection dosimetry Pub Date : 2024-11-13 DOI:10.1093/rpd/ncae071
Jun Hu, Tamon Kusumoto, Satoshi Kodaira
{"title":"利用荧光核轨道探测器评估和优化重离子测量条件。","authors":"Jun Hu, Tamon Kusumoto, Satoshi Kodaira","doi":"10.1093/rpd/ncae071","DOIUrl":null,"url":null,"abstract":"<p><p>In applying fluorescent nuclear track detectors for heavy ion measurement, the fluorescence intensity directly influences linear energy transfer (LET) estimation. However, the conventional analysis highly depends on the analyzed depth and the reference frames from the optical readout. To improve the accuracy of measurements of heavy ions, the gradient of intensity and moving average fluorescence intensity were acquired and calculated to optimize the measurement conditions. The results indicate that the intensity gradient is an alternative quantity to discriminate ions with different LET, and the moving average fluorescence intensity is readily differentiated among individual ions without overlapping values in fluorescence intensity. The scanned range of 25-45 μm is suggested to be the most suitable depth for measurement. To exclude the impact of the variation in fluorescence intensity on evaluation, it is recommended to use the quantities calculated in moving averages with depth in the future.</p>","PeriodicalId":20795,"journal":{"name":"Radiation protection dosimetry","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation and optimization of measurement conditions for heavy ions with fluorescent nuclear track detectors.\",\"authors\":\"Jun Hu, Tamon Kusumoto, Satoshi Kodaira\",\"doi\":\"10.1093/rpd/ncae071\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In applying fluorescent nuclear track detectors for heavy ion measurement, the fluorescence intensity directly influences linear energy transfer (LET) estimation. However, the conventional analysis highly depends on the analyzed depth and the reference frames from the optical readout. To improve the accuracy of measurements of heavy ions, the gradient of intensity and moving average fluorescence intensity were acquired and calculated to optimize the measurement conditions. The results indicate that the intensity gradient is an alternative quantity to discriminate ions with different LET, and the moving average fluorescence intensity is readily differentiated among individual ions without overlapping values in fluorescence intensity. The scanned range of 25-45 μm is suggested to be the most suitable depth for measurement. To exclude the impact of the variation in fluorescence intensity on evaluation, it is recommended to use the quantities calculated in moving averages with depth in the future.</p>\",\"PeriodicalId\":20795,\"journal\":{\"name\":\"Radiation protection dosimetry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-11-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation protection dosimetry\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1093/rpd/ncae071\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation protection dosimetry","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncae071","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

在应用荧光核轨道探测器进行重离子测量时,荧光强度直接影响线性能量转移(LET)的估算。然而,传统分析高度依赖于分析深度和光学读出的参考帧。为了提高重离子测量的准确性,我们采集并计算了强度梯度和移动平均荧光强度,以优化测量条件。结果表明,强度梯度是区分不同 LET 离子的一个替代量,而移动平均荧光强度则很容易区分单个离子,且不会出现荧光强度值重叠的情况。25-45 μm 的扫描范围被认为是最适合测量的深度。为排除荧光强度变化对评估的影响,建议今后使用移动平均值计算的深度量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation and optimization of measurement conditions for heavy ions with fluorescent nuclear track detectors.

In applying fluorescent nuclear track detectors for heavy ion measurement, the fluorescence intensity directly influences linear energy transfer (LET) estimation. However, the conventional analysis highly depends on the analyzed depth and the reference frames from the optical readout. To improve the accuracy of measurements of heavy ions, the gradient of intensity and moving average fluorescence intensity were acquired and calculated to optimize the measurement conditions. The results indicate that the intensity gradient is an alternative quantity to discriminate ions with different LET, and the moving average fluorescence intensity is readily differentiated among individual ions without overlapping values in fluorescence intensity. The scanned range of 25-45 μm is suggested to be the most suitable depth for measurement. To exclude the impact of the variation in fluorescence intensity on evaluation, it is recommended to use the quantities calculated in moving averages with depth in the future.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiation protection dosimetry
Radiation protection dosimetry 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
1.40
自引率
10.00%
发文量
223
审稿时长
6-12 weeks
期刊介绍: Radiation Protection Dosimetry covers all aspects of personal and environmental dosimetry and monitoring, for both ionising and non-ionising radiations. This includes biological aspects, physical concepts, biophysical dosimetry, external and internal personal dosimetry and monitoring, environmental and workplace monitoring, accident dosimetry, and dosimetry related to the protection of patients. Particular emphasis is placed on papers covering the fundamentals of dosimetry; units, radiation quantities and conversion factors. Papers covering archaeological dating are included only if the fundamental measurement method or technique, such as thermoluminescence, has direct application to personal dosimetry measurements. Papers covering the dosimetric aspects of radon or other naturally occurring radioactive materials and low level radiation are included. Animal experiments and ecological sample measurements are not included unless there is a significant relevant content reason.
期刊最新文献
A new tool for estimation of the in vivo distribution of intake radionuclides. A summary of updated UNSCEAR evaluations on medical and occupational exposures to ionising radiation and call for participation in UNSCEAR Global Surveys on radiation exposure. A pilot study to directly estimate radiation-induced mutation in large Japanese field mouse duo sample, mother and offspring, excluding unknown father, using ddRAD sequencing. An efficient and simple method for enriching metaphase cells for dicentric chromosome assay. Absorption and translocation to fruit for cesium applied on apple tree leaf surface.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1