使用 Dexter 机器人系统™进行机器人微创腹股沟疝修补术:前瞻性多中心临床研究。

Lukas Gantner, Hubert Mignot, Julius Pochhammer, Felix Grieder, Stefan Breitenstein
{"title":"使用 Dexter 机器人系统™进行机器人微创腹股沟疝修补术:前瞻性多中心临床研究。","authors":"Lukas Gantner, Hubert Mignot, Julius Pochhammer, Felix Grieder, Stefan Breitenstein","doi":"10.1007/s00464-024-11361-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Robot-assisted transabdominal preperitoneal inguinal hernia repair (rTAPP) has been established with various robotic platforms. The Dexter robotic system is an open platform consisting of a sterile surgeon's console, two robotic instrument arms, and one robotic endoscope arm. This study aimed to confirm the perioperative and early postoperative safety and clinical performance of the Dexter system in patients undergoing primary transperitoneal inguinal hernia repair.</p><p><strong>Methods: </strong>The primary objectives of this multicenter study conducted at three centers in France, Germany, and Switzerland were to document the successful completion of rTAPP procedures and the occurrence of serious adverse events (Clavien-Dindo grades III-V), device-related events up to 30 days post-surgery. The procedures were performed by three surgeons with varying levels of experience in robotic systems.</p><p><strong>Results: </strong>50 patients with a median age of 62.5 years (IQR 51.0-72.0) and BMI of 25.1 kg/cm<sup>2</sup> (IQR 23.5-28.7), respectively, underwent inguinal hernia repair (33 unilateral, 17 bilateral). All surgeries were successfully completed using three standard laparoscopy trocars. There were no conversions to open surgery, intraoperative complications or device deficiencies. The median skin-to-skin operative time was 50 min (IQR 45-60) for unilateral hernias and 96 min (IQR 84-105) for bilateral hernias. The median console time was 30 min (IQR 26-41) for unilateral and 66 min (IQR 60-77) for bilateral hernias. Twenty-six patients were discharged on the day of surgery, and 22 on postoperative day 1.</p><p><strong>Conclusion: </strong>This study confirmed the use of the Dexter system in rTAPP was feasible and safe in multicenter cohorts, with operative times consistent with the literature on other robotic platforms. Our data demonstrated the accessibility of this new robotic approach, even when adopted by surgeons new to robotics. The Dexter system emerged as a valuable device in the hernia repair toolkit for both experienced robotic surgeons and those new to the field.</p>","PeriodicalId":22174,"journal":{"name":"Surgical Endoscopy And Other Interventional Techniques","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Robotic minimally invasive inguinal hernia repair with the Dexter robotic system™: A prospective multicenter clinical investigation.\",\"authors\":\"Lukas Gantner, Hubert Mignot, Julius Pochhammer, Felix Grieder, Stefan Breitenstein\",\"doi\":\"10.1007/s00464-024-11361-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Robot-assisted transabdominal preperitoneal inguinal hernia repair (rTAPP) has been established with various robotic platforms. The Dexter robotic system is an open platform consisting of a sterile surgeon's console, two robotic instrument arms, and one robotic endoscope arm. This study aimed to confirm the perioperative and early postoperative safety and clinical performance of the Dexter system in patients undergoing primary transperitoneal inguinal hernia repair.</p><p><strong>Methods: </strong>The primary objectives of this multicenter study conducted at three centers in France, Germany, and Switzerland were to document the successful completion of rTAPP procedures and the occurrence of serious adverse events (Clavien-Dindo grades III-V), device-related events up to 30 days post-surgery. The procedures were performed by three surgeons with varying levels of experience in robotic systems.</p><p><strong>Results: </strong>50 patients with a median age of 62.5 years (IQR 51.0-72.0) and BMI of 25.1 kg/cm<sup>2</sup> (IQR 23.5-28.7), respectively, underwent inguinal hernia repair (33 unilateral, 17 bilateral). All surgeries were successfully completed using three standard laparoscopy trocars. There were no conversions to open surgery, intraoperative complications or device deficiencies. The median skin-to-skin operative time was 50 min (IQR 45-60) for unilateral hernias and 96 min (IQR 84-105) for bilateral hernias. The median console time was 30 min (IQR 26-41) for unilateral and 66 min (IQR 60-77) for bilateral hernias. Twenty-six patients were discharged on the day of surgery, and 22 on postoperative day 1.</p><p><strong>Conclusion: </strong>This study confirmed the use of the Dexter system in rTAPP was feasible and safe in multicenter cohorts, with operative times consistent with the literature on other robotic platforms. Our data demonstrated the accessibility of this new robotic approach, even when adopted by surgeons new to robotics. The Dexter system emerged as a valuable device in the hernia repair toolkit for both experienced robotic surgeons and those new to the field.</p>\",\"PeriodicalId\":22174,\"journal\":{\"name\":\"Surgical Endoscopy And Other Interventional Techniques\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2024-11-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Surgical Endoscopy And Other Interventional Techniques\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00464-024-11361-1\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Endoscopy And Other Interventional Techniques","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00464-024-11361-1","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

背景:机器人辅助经腹腹膜前腹股沟疝修补术(rTAPP)已在各种机器人平台上应用。Dexter 机器人系统是一个开放式平台,由一个无菌外科医生控制台、两个机器人器械臂和一个机器人内窥镜臂组成。本研究旨在确认 Dexter 系统在接受经腹膜腹股沟疝修补术的患者围手术期和术后早期的安全性和临床表现:这项多中心研究在法国、德国和瑞士的三个中心进行,主要目的是记录 rTAPP 手术的成功完成情况、严重不良事件(Clavien-Dindo III-V 级)的发生情况以及术后 30 天内与设备相关的事件。手术由三位在机器人系统方面具有不同经验的外科医生完成:50名中位数年龄为62.5岁(IQR 51.0-72.0)、体重指数为25.1 kg/cm2(IQR 23.5-28.7)的患者接受了腹股沟疝修补术(33例单侧,17例双侧)。所有手术均使用三个标准腹腔镜套管成功完成。没有出现转为开腹手术、术中并发症或设备缺陷。单侧疝气的皮对皮手术时间中位数为 50 分钟(IQR 45-60),双侧疝气的皮对皮手术时间中位数为 96 分钟(IQR 84-105)。单侧疝气的中位控制台时间为 30 分钟(IQR 26-41),双侧疝气的中位控制台时间为 66 分钟(IQR 60-77)。26名患者在手术当天出院,22名患者在术后第1天出院:这项研究证实,在多中心群组中使用 Dexter 系统进行 rTAPP 是可行且安全的,手术时间与其他机器人平台的文献一致。我们的数据证明了这种新型机器人方法的易用性,即使是刚接触机器人技术的外科医生也能使用。对于经验丰富的机器人外科医生和新手来说,Dexter系统都是疝修补工具包中的重要设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Robotic minimally invasive inguinal hernia repair with the Dexter robotic system™: A prospective multicenter clinical investigation.

Background: Robot-assisted transabdominal preperitoneal inguinal hernia repair (rTAPP) has been established with various robotic platforms. The Dexter robotic system is an open platform consisting of a sterile surgeon's console, two robotic instrument arms, and one robotic endoscope arm. This study aimed to confirm the perioperative and early postoperative safety and clinical performance of the Dexter system in patients undergoing primary transperitoneal inguinal hernia repair.

Methods: The primary objectives of this multicenter study conducted at three centers in France, Germany, and Switzerland were to document the successful completion of rTAPP procedures and the occurrence of serious adverse events (Clavien-Dindo grades III-V), device-related events up to 30 days post-surgery. The procedures were performed by three surgeons with varying levels of experience in robotic systems.

Results: 50 patients with a median age of 62.5 years (IQR 51.0-72.0) and BMI of 25.1 kg/cm2 (IQR 23.5-28.7), respectively, underwent inguinal hernia repair (33 unilateral, 17 bilateral). All surgeries were successfully completed using three standard laparoscopy trocars. There were no conversions to open surgery, intraoperative complications or device deficiencies. The median skin-to-skin operative time was 50 min (IQR 45-60) for unilateral hernias and 96 min (IQR 84-105) for bilateral hernias. The median console time was 30 min (IQR 26-41) for unilateral and 66 min (IQR 60-77) for bilateral hernias. Twenty-six patients were discharged on the day of surgery, and 22 on postoperative day 1.

Conclusion: This study confirmed the use of the Dexter system in rTAPP was feasible and safe in multicenter cohorts, with operative times consistent with the literature on other robotic platforms. Our data demonstrated the accessibility of this new robotic approach, even when adopted by surgeons new to robotics. The Dexter system emerged as a valuable device in the hernia repair toolkit for both experienced robotic surgeons and those new to the field.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.10
自引率
12.90%
发文量
890
审稿时长
6 months
期刊介绍: Uniquely positioned at the interface between various medical and surgical disciplines, Surgical Endoscopy serves as a focal point for the international surgical community to exchange information on practice, theory, and research. Topics covered in the journal include: -Surgical aspects of: Interventional endoscopy, Ultrasound, Other techniques in the fields of gastroenterology, obstetrics, gynecology, and urology, -Gastroenterologic surgery -Thoracic surgery -Traumatic surgery -Orthopedic surgery -Pediatric surgery
期刊最新文献
Clinical features and risk factors for colorectal gas explosion during digestive endoscopy and surgery: a systematic review. Comparison between robotic-assisted Kasai portoenterostomy and open Kasai portoenterostomy in patients with biliary atresia. Inflammation-attenuating effect of carbon dioxide versus room-air environment in a rat laparotomy model. Laparoscopic distal pancreatectomy with pancreatic remnant-gastric coverage: a modified technique to reduce postoperative pancreatic fistula. Minimally invasive intraperitoneal onlay mesh plus (IPOM +) repair versus enhanced-view totally extraperitoneal (e-TEP) repair for ventral hernias: a systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1