游离肌腱的长度会影响跟腱的损伤风险吗?有限元研究。

IF 2 Q2 ORTHOPEDICS Journal of Experimental Orthopaedics Pub Date : 2024-11-14 DOI:10.1002/jeo2.70036
Pedro Diniz, Carlos Quental, Hélder Pereira, André Soares Ferreira, Gino M. M. J. Kerkhoffs, Frederico Castelo Ferreira, João Folgado
{"title":"游离肌腱的长度会影响跟腱的损伤风险吗?有限元研究。","authors":"Pedro Diniz,&nbsp;Carlos Quental,&nbsp;Hélder Pereira,&nbsp;André Soares Ferreira,&nbsp;Gino M. M. J. Kerkhoffs,&nbsp;Frederico Castelo Ferreira,&nbsp;João Folgado","doi":"10.1002/jeo2.70036","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>The Achilles tendon is a common injury site, but anatomical risk factors for injury are relatively unexplored in the literature. This study aimed to evaluate whether changes in free tendon length would influence the results of a simulated rupture of the Achilles tendon.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Using a previously validated 3D finite element model of the free and aponeurotic Achilles tendon as a basis, two additional finite element models with 25% decreased and increased free tendon lengths were created. The finite element models were sequentially loaded from 2500 to 3500N in 100N increments, and the total volume of elements exhibiting a maximal principal strain above 10% was recorded. An Achilles tendon rupture was considered to have occurred when a continuous group of elements with a volume of at least 3 mm<sup>3</sup> exhibited a maximum principal strain above 10%. Models were compared regarding the smallest load that met the rupture criterion and plots of the percentage of elements exhibiting maximum principal strains above 10% across the loading range. Sensitivity analyses assessed the influence of subtendon division variations and subtendon sliding restriction on the results.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Rupture loads and plots of the percentage of elements with maximum principal strains above 10% were similar between models, regardless of the free tendon length. No models met the rupture criterion when simulations were run without subtendon sliding. Rupture loads in the subtendon division variation models were correlated with the subtendon cross-sectional areas.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The simulated rupture results of the Achilles tendon were sensitive to variations in subtendon cross-sectional areas but not in free tendon length.</p>\n </section>\n \n <section>\n \n <h3> Level of Evidence</h3>\n \n <p>Level V.</p>\n </section>\n </div>","PeriodicalId":36909,"journal":{"name":"Journal of Experimental Orthopaedics","volume":"11 4","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11561656/pdf/","citationCount":"0","resultStr":"{\"title\":\"Does free tendon length influence the injury risk of the Achilles tendon? A finite element study\",\"authors\":\"Pedro Diniz,&nbsp;Carlos Quental,&nbsp;Hélder Pereira,&nbsp;André Soares Ferreira,&nbsp;Gino M. M. J. Kerkhoffs,&nbsp;Frederico Castelo Ferreira,&nbsp;João Folgado\",\"doi\":\"10.1002/jeo2.70036\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Purpose</h3>\\n \\n <p>The Achilles tendon is a common injury site, but anatomical risk factors for injury are relatively unexplored in the literature. This study aimed to evaluate whether changes in free tendon length would influence the results of a simulated rupture of the Achilles tendon.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>Using a previously validated 3D finite element model of the free and aponeurotic Achilles tendon as a basis, two additional finite element models with 25% decreased and increased free tendon lengths were created. The finite element models were sequentially loaded from 2500 to 3500N in 100N increments, and the total volume of elements exhibiting a maximal principal strain above 10% was recorded. An Achilles tendon rupture was considered to have occurred when a continuous group of elements with a volume of at least 3 mm<sup>3</sup> exhibited a maximum principal strain above 10%. Models were compared regarding the smallest load that met the rupture criterion and plots of the percentage of elements exhibiting maximum principal strains above 10% across the loading range. Sensitivity analyses assessed the influence of subtendon division variations and subtendon sliding restriction on the results.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Rupture loads and plots of the percentage of elements with maximum principal strains above 10% were similar between models, regardless of the free tendon length. No models met the rupture criterion when simulations were run without subtendon sliding. Rupture loads in the subtendon division variation models were correlated with the subtendon cross-sectional areas.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>The simulated rupture results of the Achilles tendon were sensitive to variations in subtendon cross-sectional areas but not in free tendon length.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Level of Evidence</h3>\\n \\n <p>Level V.</p>\\n </section>\\n </div>\",\"PeriodicalId\":36909,\"journal\":{\"name\":\"Journal of Experimental Orthopaedics\",\"volume\":\"11 4\",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-11-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11561656/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Experimental Orthopaedics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jeo2.70036\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Experimental Orthopaedics","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jeo2.70036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:跟腱是常见的损伤部位,但文献中对其损伤的解剖学风险因素的研究相对较少。本研究旨在评估游离肌腱长度的变化是否会影响跟腱模拟断裂的结果:方法:以之前验证过的跟腱游离和肌腱三维有限元模型为基础,创建了游离肌腱长度减少 25% 和增加 25% 的两个额外有限元模型。以 100N 为增量,从 2500N 到 3500N 依次对有限元模型进行加载,并记录显示最大主应变超过 10% 的元素的总体积。当体积至少为 3 立方毫米的连续元素组的最大主应变超过 10%时,即认为跟腱断裂发生。我们比较了符合断裂标准的最小载荷模型,并绘制了在整个载荷范围内最大主应变超过 10% 的元素百分比图。敏感性分析评估了副腱划分变化和副腱滑动限制对结果的影响:结果:无论自由肌腱长度如何,不同模型的断裂荷载和最大主应变超过 10%的元素百分比图相似。在没有副肌滑动的情况下进行模拟时,没有任何模型符合断裂标准。副腱分裂变化模型的断裂荷载与副腱横截面积相关:结论:跟腱的模拟断裂结果对亚腱横截面积的变化敏感,但对自由肌腱长度的变化不敏感:证据等级:V 级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Does free tendon length influence the injury risk of the Achilles tendon? A finite element study

Purpose

The Achilles tendon is a common injury site, but anatomical risk factors for injury are relatively unexplored in the literature. This study aimed to evaluate whether changes in free tendon length would influence the results of a simulated rupture of the Achilles tendon.

Methods

Using a previously validated 3D finite element model of the free and aponeurotic Achilles tendon as a basis, two additional finite element models with 25% decreased and increased free tendon lengths were created. The finite element models were sequentially loaded from 2500 to 3500N in 100N increments, and the total volume of elements exhibiting a maximal principal strain above 10% was recorded. An Achilles tendon rupture was considered to have occurred when a continuous group of elements with a volume of at least 3 mm3 exhibited a maximum principal strain above 10%. Models were compared regarding the smallest load that met the rupture criterion and plots of the percentage of elements exhibiting maximum principal strains above 10% across the loading range. Sensitivity analyses assessed the influence of subtendon division variations and subtendon sliding restriction on the results.

Results

Rupture loads and plots of the percentage of elements with maximum principal strains above 10% were similar between models, regardless of the free tendon length. No models met the rupture criterion when simulations were run without subtendon sliding. Rupture loads in the subtendon division variation models were correlated with the subtendon cross-sectional areas.

Conclusions

The simulated rupture results of the Achilles tendon were sensitive to variations in subtendon cross-sectional areas but not in free tendon length.

Level of Evidence

Level V.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Experimental Orthopaedics
Journal of Experimental Orthopaedics Medicine-Orthopedics and Sports Medicine
CiteScore
3.20
自引率
5.60%
发文量
114
审稿时长
13 weeks
期刊最新文献
Machine learning in knee injury sequelae detection: Unravelling the role of psychological factors and preventing long-term sequelae Anteroposterior axis of the tibia for kinematic aligned total knee arthroplasty Radiographic acceptable zone of endobutton placement in ACL reconstruction: A prospective study Does free tendon length influence the injury risk of the Achilles tendon? A finite element study Daily physical activity following unicompartmental knee arthroplasty: A pilot study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1