[眼科电生理学]。

Die Ophthalmologie Pub Date : 2024-12-01 Epub Date: 2024-11-15 DOI:10.1007/s00347-024-02134-1
Laura Kühlewein, Katarina Stingl
{"title":"[眼科电生理学]。","authors":"Laura Kühlewein, Katarina Stingl","doi":"10.1007/s00347-024-02134-1","DOIUrl":null,"url":null,"abstract":"<p><p>Electrophysiological examinations are used in ophthalmology to determine the functionality of the neurons of the visual pathway. As electrophysiological examinations are independent of the subjective perception and response of the patient, they are considered to be objective functional diagnostics of vision. Electroretinography (ERG) is used to examine the retina (especially the photoreceptors), electro-oculography (EOG) is used to examine the functionality of the retinal pigment epithelium and visually evoked potentials (VEP) are used to evaluate the integrity of the entire visual pathway. Abnormalities in electrophysiological responses should always be interpreted in the context of other functional and morphological findings.</p>","PeriodicalId":72808,"journal":{"name":"Die Ophthalmologie","volume":" ","pages":"1001-1010"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Electrophysiology in ophthalmology].\",\"authors\":\"Laura Kühlewein, Katarina Stingl\",\"doi\":\"10.1007/s00347-024-02134-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Electrophysiological examinations are used in ophthalmology to determine the functionality of the neurons of the visual pathway. As electrophysiological examinations are independent of the subjective perception and response of the patient, they are considered to be objective functional diagnostics of vision. Electroretinography (ERG) is used to examine the retina (especially the photoreceptors), electro-oculography (EOG) is used to examine the functionality of the retinal pigment epithelium and visually evoked potentials (VEP) are used to evaluate the integrity of the entire visual pathway. Abnormalities in electrophysiological responses should always be interpreted in the context of other functional and morphological findings.</p>\",\"PeriodicalId\":72808,\"journal\":{\"name\":\"Die Ophthalmologie\",\"volume\":\" \",\"pages\":\"1001-1010\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Die Ophthalmologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s00347-024-02134-1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/11/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Die Ophthalmologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00347-024-02134-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/15 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电生理检查用于眼科,以确定视觉通路神经元的功能。由于电生理检查不受患者主观感觉和反应的影响,因此被认为是客观的视力功能诊断。视网膜电图(ERG)用于检查视网膜(尤其是光感受器),眼电图(EOG)用于检查视网膜色素上皮细胞的功能,视觉诱发电位(VEP)用于评估整个视觉通路的完整性。电生理反应异常应始终结合其他功能和形态学检查结果进行解释。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Electrophysiology in ophthalmology].

Electrophysiological examinations are used in ophthalmology to determine the functionality of the neurons of the visual pathway. As electrophysiological examinations are independent of the subjective perception and response of the patient, they are considered to be objective functional diagnostics of vision. Electroretinography (ERG) is used to examine the retina (especially the photoreceptors), electro-oculography (EOG) is used to examine the functionality of the retinal pigment epithelium and visually evoked potentials (VEP) are used to evaluate the integrity of the entire visual pathway. Abnormalities in electrophysiological responses should always be interpreted in the context of other functional and morphological findings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Imaging and classification of central serous chorioretinopathy-What do I really need?] [Symptomatic Rathke's cyst of the pituitary gland-When the eye uncovers the invisible]. [Geographic-like paraproteinemic keratopathy in type I cryoglobulinemic vasculitis: a case report]. [An unusual conjunctival finding]. [Sebaceous gland carcinoma in disguise].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1