通风期间仓库温度电缆布局优化模拟研究

IF 2.7 3区 农林科学 Q3 ENGINEERING, CHEMICAL Journal of Food Process Engineering Pub Date : 2024-11-14 DOI:10.1111/jfpe.14769
Kaimin Yang, Fengjiao Chu, Yuancheng Wang, Xiaoqian Dong
{"title":"通风期间仓库温度电缆布局优化模拟研究","authors":"Kaimin Yang,&nbsp;Fengjiao Chu,&nbsp;Yuancheng Wang,&nbsp;Xiaoqian Dong","doi":"10.1111/jfpe.14769","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>The temperature data obtained from cables monitoring stored grain are crucial for real-time surveillance of grain storage and serve as a reference for processes such as ventilation. This study focuses on optimizing the arrangement of temperature cables within the warehouse and employing numerical simulations to analyze the variation in grain temperature during a 7-day cooling ventilation period. By comparing the predicted average temperature of bulk grain with the temperatures recorded by cable sensors, the study evaluates the potential benefits and cost implications of various cable layouts. The maximum difference in the average temperature between the monitoring temperature by cables and the predicted temperature in bulk grain was 0.70°C, and the root mean square error (RMSE) was 25.83% when the cables were arranged according to the national standard (National Standard of P.R. China, GB/T 26882.1-2011). The study further examines the impact of optimizing cable layout, including variations in horizontal spacing, on the RMSE. It was found that reducing cable spacing decreased the RMSE but necessitated an increased number of cables. Conversely, increasing cable spacing led to a decrease in the number of cables but resulted in a higher RMSE. Based on an optimized non-uniform layout with the less cables, which were inserted with dense cables near the wall and sparse cables in bulk grain, it was found that the RMSE was reduced to 22.23%, and the number of the cables was reduced by four cables compared to the national standard layout. The non-uniform layout was also verified for applicability in large-scale warehouses, showing a reduction of 26 cables compared to the national standard. The results demonstrated that the current cable layout of the national standard needs optimization, and that the optimization direction of the uniform layout does not guarantee economy and accuracy at the same time during the monitoring temperature in bulk grain. The non-uniform cable layout, with fewer cables and improved monitoring accuracy, presents a promising approach for practical application.</p>\n </div>","PeriodicalId":15932,"journal":{"name":"Journal of Food Process Engineering","volume":"47 11","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2024-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simulation Study on the Optimization of Temperature Cable Layout in a Warehouse During the Ventilation\",\"authors\":\"Kaimin Yang,&nbsp;Fengjiao Chu,&nbsp;Yuancheng Wang,&nbsp;Xiaoqian Dong\",\"doi\":\"10.1111/jfpe.14769\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <p>The temperature data obtained from cables monitoring stored grain are crucial for real-time surveillance of grain storage and serve as a reference for processes such as ventilation. This study focuses on optimizing the arrangement of temperature cables within the warehouse and employing numerical simulations to analyze the variation in grain temperature during a 7-day cooling ventilation period. By comparing the predicted average temperature of bulk grain with the temperatures recorded by cable sensors, the study evaluates the potential benefits and cost implications of various cable layouts. The maximum difference in the average temperature between the monitoring temperature by cables and the predicted temperature in bulk grain was 0.70°C, and the root mean square error (RMSE) was 25.83% when the cables were arranged according to the national standard (National Standard of P.R. China, GB/T 26882.1-2011). The study further examines the impact of optimizing cable layout, including variations in horizontal spacing, on the RMSE. It was found that reducing cable spacing decreased the RMSE but necessitated an increased number of cables. Conversely, increasing cable spacing led to a decrease in the number of cables but resulted in a higher RMSE. Based on an optimized non-uniform layout with the less cables, which were inserted with dense cables near the wall and sparse cables in bulk grain, it was found that the RMSE was reduced to 22.23%, and the number of the cables was reduced by four cables compared to the national standard layout. The non-uniform layout was also verified for applicability in large-scale warehouses, showing a reduction of 26 cables compared to the national standard. The results demonstrated that the current cable layout of the national standard needs optimization, and that the optimization direction of the uniform layout does not guarantee economy and accuracy at the same time during the monitoring temperature in bulk grain. The non-uniform cable layout, with fewer cables and improved monitoring accuracy, presents a promising approach for practical application.</p>\\n </div>\",\"PeriodicalId\":15932,\"journal\":{\"name\":\"Journal of Food Process Engineering\",\"volume\":\"47 11\",\"pages\":\"\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-11-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Food Process Engineering\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/jfpe.14769\",\"RegionNum\":3,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, CHEMICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Food Process Engineering","FirstCategoryId":"97","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jfpe.14769","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0

摘要

从监测储存谷物的电缆中获得的温度数据对于实时监控谷物储存至关重要,并可作为通风等过程的参考。本研究的重点是优化仓库内温度电缆的布置,并采用数值模拟分析 7 天冷却通风期间谷物温度的变化。通过比较散装谷物的预测平均温度和电缆传感器记录的温度,该研究评估了各种电缆布置的潜在效益和成本影响。根据国家标准(中国国家标准,GB/T 26882.1-2011)布置电缆时,电缆监测温度与散装谷物预测温度之间的平均温度最大相差 0.70°C,均方根误差 (RMSE) 为 25.83%。研究进一步探讨了优化电缆布局(包括水平间距的变化)对 RMSE 的影响。研究发现,减小电缆间距可降低均方根误差,但必须增加电缆数量。相反,增加电缆间距会减少电缆数量,但会导致均方根误差增大。根据优化的非均匀布局,在靠近墙壁的地方插入密集电缆,而在散粒中插入稀疏电缆,结果发现与国家标准布局相比,均方根误差降低了 22.23%,电缆数量减少了 4 根。此外,还验证了非均匀布局在大型仓库中的适用性,结果表明与国家标准相比,非均匀布局减少了 26 根电缆。结果表明,目前国家标准的电缆布局需要优化,而统一布局的优化方向无法同时保证散装粮食温度监测的经济性和准确性。非均匀电缆布局既减少了电缆数量,又提高了监测精度,是一种具有实际应用前景的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simulation Study on the Optimization of Temperature Cable Layout in a Warehouse During the Ventilation

The temperature data obtained from cables monitoring stored grain are crucial for real-time surveillance of grain storage and serve as a reference for processes such as ventilation. This study focuses on optimizing the arrangement of temperature cables within the warehouse and employing numerical simulations to analyze the variation in grain temperature during a 7-day cooling ventilation period. By comparing the predicted average temperature of bulk grain with the temperatures recorded by cable sensors, the study evaluates the potential benefits and cost implications of various cable layouts. The maximum difference in the average temperature between the monitoring temperature by cables and the predicted temperature in bulk grain was 0.70°C, and the root mean square error (RMSE) was 25.83% when the cables were arranged according to the national standard (National Standard of P.R. China, GB/T 26882.1-2011). The study further examines the impact of optimizing cable layout, including variations in horizontal spacing, on the RMSE. It was found that reducing cable spacing decreased the RMSE but necessitated an increased number of cables. Conversely, increasing cable spacing led to a decrease in the number of cables but resulted in a higher RMSE. Based on an optimized non-uniform layout with the less cables, which were inserted with dense cables near the wall and sparse cables in bulk grain, it was found that the RMSE was reduced to 22.23%, and the number of the cables was reduced by four cables compared to the national standard layout. The non-uniform layout was also verified for applicability in large-scale warehouses, showing a reduction of 26 cables compared to the national standard. The results demonstrated that the current cable layout of the national standard needs optimization, and that the optimization direction of the uniform layout does not guarantee economy and accuracy at the same time during the monitoring temperature in bulk grain. The non-uniform cable layout, with fewer cables and improved monitoring accuracy, presents a promising approach for practical application.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Food Process Engineering
Journal of Food Process Engineering 工程技术-工程:化工
CiteScore
5.70
自引率
10.00%
发文量
259
审稿时长
2 months
期刊介绍: This international research journal focuses on the engineering aspects of post-production handling, storage, processing, packaging, and distribution of food. Read by researchers, food and chemical engineers, and industry experts, this is the only international journal specifically devoted to the engineering aspects of food processing. Co-Editors M. Elena Castell-Perez and Rosana Moreira, both of Texas A&M University, welcome papers covering the best original research on applications of engineering principles and concepts to food and food processes.
期刊最新文献
Application of Image-Based Features and Machine Learning Models to Detect Brick Powder Adulteration in Red Chili Powder Effects of Egg on Cake Batter Rheology and Sponge Cake Texture Effects of High Pressure and Ultrasonication Pretreatments and Supercritical Carbon Dioxide Extraction on Physico-Chemical Properties of Edible Insect Oils Numerical Simulation and Quality Analysis of Carrot Crisps Drying Based on Freezing Pretreatment Cost Estimation for the Preservation of Selected Food/Crop Products With Ozone
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1