{"title":"根据视觉模拟量表输注对乙酰氨基酚对分娩过程中不同疼痛强度的影响,随机对照试验。","authors":"Wajeha Najeeb, Naima Komal, Mudassar Noor, Muhammad Alamgir Khan, Abeera Chaudry","doi":"10.12669/pjms.40.10.8425","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Acetaminophen (Paracetamol) is the most widely used analgesic. We aimed to determine its efficacy in labour with varying pain intensity, to make labour less painful for women.</p><p><strong>Methods: </strong>This randomized controlled trial was conducted on primigravida's in their active phase of first stage of labour at Pharmacology department of Army Medical College, National University of Medical Sciences in collaboration with Gynecology department of Pak Emirates Military hospital, Rawalpindi. It was a registered trial with trial number of IRCT20220308054220N1. Duration of study was from May 2022 to October 2022. Patients were divided into two groups, Group-I received two doses of I/V 100 ml normal saline whereas Group-II received I/V two doses of 1000 mg acetaminophen in 100 ml normal saline. Calculated sample size was 130, 65 in each group. Visual analogue scale was used as a tool for data measurement. Data was analysed using split plot anova test.</p><p><strong>Results: </strong>Mean VAS in acetaminophen infusion group was found to be less than placebo for 1<sup>st</sup> dose, but this effect was apparent only one hour after 2<sup>nd</sup> dose intervention. The difference in means between groups was statistically significant only for 1<sup>st</sup> dose with p-value of 0.003 (for second dose p-value 0.21). In acetaminophen infusion group, for both doses mean VAS decreased as an immediate effect of drug, but then it increased with time. The difference in VAS between intervals had p-value of <0.001 for 1<sup>st</sup> dose and 0.005 for 2<sup>nd</sup> dose.</p><p><strong>Conclusion: </strong>Acetaminophen is an effective non opioid labour analgesic in active phase of first stage of labour.</p>","PeriodicalId":19958,"journal":{"name":"Pakistan Journal of Medical Sciences","volume":"40 10","pages":"2163-2169"},"PeriodicalIF":1.2000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11568724/pdf/","citationCount":"0","resultStr":"{\"title\":\"Outcomes of acetaminophen infusion on visual analogue scale with varying pain intensity during labour, A randomized controlled trial.\",\"authors\":\"Wajeha Najeeb, Naima Komal, Mudassar Noor, Muhammad Alamgir Khan, Abeera Chaudry\",\"doi\":\"10.12669/pjms.40.10.8425\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Acetaminophen (Paracetamol) is the most widely used analgesic. We aimed to determine its efficacy in labour with varying pain intensity, to make labour less painful for women.</p><p><strong>Methods: </strong>This randomized controlled trial was conducted on primigravida's in their active phase of first stage of labour at Pharmacology department of Army Medical College, National University of Medical Sciences in collaboration with Gynecology department of Pak Emirates Military hospital, Rawalpindi. It was a registered trial with trial number of IRCT20220308054220N1. Duration of study was from May 2022 to October 2022. Patients were divided into two groups, Group-I received two doses of I/V 100 ml normal saline whereas Group-II received I/V two doses of 1000 mg acetaminophen in 100 ml normal saline. Calculated sample size was 130, 65 in each group. Visual analogue scale was used as a tool for data measurement. Data was analysed using split plot anova test.</p><p><strong>Results: </strong>Mean VAS in acetaminophen infusion group was found to be less than placebo for 1<sup>st</sup> dose, but this effect was apparent only one hour after 2<sup>nd</sup> dose intervention. The difference in means between groups was statistically significant only for 1<sup>st</sup> dose with p-value of 0.003 (for second dose p-value 0.21). In acetaminophen infusion group, for both doses mean VAS decreased as an immediate effect of drug, but then it increased with time. The difference in VAS between intervals had p-value of <0.001 for 1<sup>st</sup> dose and 0.005 for 2<sup>nd</sup> dose.</p><p><strong>Conclusion: </strong>Acetaminophen is an effective non opioid labour analgesic in active phase of first stage of labour.</p>\",\"PeriodicalId\":19958,\"journal\":{\"name\":\"Pakistan Journal of Medical Sciences\",\"volume\":\"40 10\",\"pages\":\"2163-2169\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11568724/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pakistan Journal of Medical Sciences\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.12669/pjms.40.10.8425\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pakistan Journal of Medical Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.12669/pjms.40.10.8425","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
摘要
目的:对乙酰氨基酚(扑热息痛对乙酰氨基酚(扑热息痛)是最广泛使用的镇痛药。我们旨在确定对乙酰氨基酚在不同疼痛强度的分娩中的疗效,以减轻产妇分娩时的疼痛:这项随机对照试验是在国立医科大学陆军医学院药理学系与拉瓦尔品第 Pak Emirates 军事医院妇科合作下,对处于第一产程活跃期的初产妇进行的。这是一项注册试验,试验编号为 IRCT20220308054220N1。研究时间为 2022 年 5 月至 2022 年 10 月。患者被分为两组,第一组接受 100 毫升生理盐水静脉滴注两次,第二组接受 100 毫升生理盐水静脉滴注两次,每次 1000 毫克对乙酰氨基酚。计算样本量为 130 人,每组 65 人。采用视觉模拟量表进行数据测量。数据分析采用分裂图anova检验:结果:输注对乙酰氨基酚组的平均 VAS 值低于输注第一剂安慰剂组,但这种效果在输注第二剂后一小时才显现出来。组间平均值的差异仅在第一剂时有统计学意义,P 值为 0.003(第二剂时的 P 值为 0.21)。在对乙酰氨基酚输注组中,两种剂量的平均 VAS 值均有所下降,这是药物的即时效应,但随后随着时间的推移而上升。不同剂量之间的 VAS 差异,第一次剂量的 p 值为 0.005,第二次剂量的 p 值为 0.005:在第一产程的活跃期,对乙酰氨基酚是一种有效的非阿片类分娩镇痛药。
Outcomes of acetaminophen infusion on visual analogue scale with varying pain intensity during labour, A randomized controlled trial.
Objective: Acetaminophen (Paracetamol) is the most widely used analgesic. We aimed to determine its efficacy in labour with varying pain intensity, to make labour less painful for women.
Methods: This randomized controlled trial was conducted on primigravida's in their active phase of first stage of labour at Pharmacology department of Army Medical College, National University of Medical Sciences in collaboration with Gynecology department of Pak Emirates Military hospital, Rawalpindi. It was a registered trial with trial number of IRCT20220308054220N1. Duration of study was from May 2022 to October 2022. Patients were divided into two groups, Group-I received two doses of I/V 100 ml normal saline whereas Group-II received I/V two doses of 1000 mg acetaminophen in 100 ml normal saline. Calculated sample size was 130, 65 in each group. Visual analogue scale was used as a tool for data measurement. Data was analysed using split plot anova test.
Results: Mean VAS in acetaminophen infusion group was found to be less than placebo for 1st dose, but this effect was apparent only one hour after 2nd dose intervention. The difference in means between groups was statistically significant only for 1st dose with p-value of 0.003 (for second dose p-value 0.21). In acetaminophen infusion group, for both doses mean VAS decreased as an immediate effect of drug, but then it increased with time. The difference in VAS between intervals had p-value of <0.001 for 1st dose and 0.005 for 2nd dose.
Conclusion: Acetaminophen is an effective non opioid labour analgesic in active phase of first stage of labour.
期刊介绍:
It is a peer reviewed medical journal published regularly since 1984. It was previously known as quarterly "SPECIALIST" till December 31st 1999. It publishes original research articles, review articles, current practices, short communications & case reports. It attracts manuscripts not only from within Pakistan but also from over fifty countries from abroad.
Copies of PJMS are sent to all the import medical libraries all over Pakistan and overseas particularly in South East Asia and Asia Pacific besides WHO EMRO Region countries. Eminent members of the medical profession at home and abroad regularly contribute their write-ups, manuscripts in our publications. We pursue an independent editorial policy, which allows an opportunity to the healthcare professionals to express their views without any fear or favour. That is why many opinion makers among the medical and pharmaceutical profession use this publication to communicate their viewpoint.