Chen Xu, David Hülsmeier, Mareike Buhl, Birger Kollmeier
{"title":"在通过智能手机进行心理声学评估时,注意力不集中如何影响自适应程序的稳健性和效率?","authors":"Chen Xu, David Hülsmeier, Mareike Buhl, Birger Kollmeier","doi":"10.1177/23312165241288051","DOIUrl":null,"url":null,"abstract":"<p><p>Inattention plays a critical role in the accuracy of threshold measurements, e.g., when using mobile devices. To describe the influence of distraction, long- and short-term inattention models based on either a stationary or a non-stationary psychometric function were developed and used to generate three simulated listeners: fully-, moderately-, and non-concentrated listeners. Six established adaptive procedures were assessed via Monte-Carlo simulations in combination with the inattention models and compared with a newly proposed method: the graded response bracketing procedure (GRaBr). Robustness was examined by bias and root mean square error between the \"true\" and estimated thresholds while efficiency was evaluated using rates of convergence and a normalized efficiency index. The findings show that inattention has a detrimental impact on adaptive procedure performance-especially for the short-term inattentive listener-and that several model-based procedures relying on a consistent response behavior of the listener are prone to errors owing to inattention. The model-free procedure GRaBr, on the other hand, is considerably robust and efficient in spite of the (assumed) inattention. As a result, adaptive techniques with desired properties (i.e., high robustness and efficiency) as revealed in our simulations-such as GRaBr-appear to be advantageous for mobile devices or in laboratory tests with untrained subjects.</p>","PeriodicalId":48678,"journal":{"name":"Trends in Hearing","volume":"28 ","pages":"23312165241288051"},"PeriodicalIF":2.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11574912/pdf/","citationCount":"0","resultStr":"{\"title\":\"How Does Inattention Influence the Robustness and Efficiency of Adaptive Procedures in the Context of Psychoacoustic Assessments via Smartphone?\",\"authors\":\"Chen Xu, David Hülsmeier, Mareike Buhl, Birger Kollmeier\",\"doi\":\"10.1177/23312165241288051\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Inattention plays a critical role in the accuracy of threshold measurements, e.g., when using mobile devices. To describe the influence of distraction, long- and short-term inattention models based on either a stationary or a non-stationary psychometric function were developed and used to generate three simulated listeners: fully-, moderately-, and non-concentrated listeners. Six established adaptive procedures were assessed via Monte-Carlo simulations in combination with the inattention models and compared with a newly proposed method: the graded response bracketing procedure (GRaBr). Robustness was examined by bias and root mean square error between the \\\"true\\\" and estimated thresholds while efficiency was evaluated using rates of convergence and a normalized efficiency index. The findings show that inattention has a detrimental impact on adaptive procedure performance-especially for the short-term inattentive listener-and that several model-based procedures relying on a consistent response behavior of the listener are prone to errors owing to inattention. The model-free procedure GRaBr, on the other hand, is considerably robust and efficient in spite of the (assumed) inattention. As a result, adaptive techniques with desired properties (i.e., high robustness and efficiency) as revealed in our simulations-such as GRaBr-appear to be advantageous for mobile devices or in laboratory tests with untrained subjects.</p>\",\"PeriodicalId\":48678,\"journal\":{\"name\":\"Trends in Hearing\",\"volume\":\"28 \",\"pages\":\"23312165241288051\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11574912/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Trends in Hearing\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/23312165241288051\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trends in Hearing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/23312165241288051","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
How Does Inattention Influence the Robustness and Efficiency of Adaptive Procedures in the Context of Psychoacoustic Assessments via Smartphone?
Inattention plays a critical role in the accuracy of threshold measurements, e.g., when using mobile devices. To describe the influence of distraction, long- and short-term inattention models based on either a stationary or a non-stationary psychometric function were developed and used to generate three simulated listeners: fully-, moderately-, and non-concentrated listeners. Six established adaptive procedures were assessed via Monte-Carlo simulations in combination with the inattention models and compared with a newly proposed method: the graded response bracketing procedure (GRaBr). Robustness was examined by bias and root mean square error between the "true" and estimated thresholds while efficiency was evaluated using rates of convergence and a normalized efficiency index. The findings show that inattention has a detrimental impact on adaptive procedure performance-especially for the short-term inattentive listener-and that several model-based procedures relying on a consistent response behavior of the listener are prone to errors owing to inattention. The model-free procedure GRaBr, on the other hand, is considerably robust and efficient in spite of the (assumed) inattention. As a result, adaptive techniques with desired properties (i.e., high robustness and efficiency) as revealed in our simulations-such as GRaBr-appear to be advantageous for mobile devices or in laboratory tests with untrained subjects.
Trends in HearingAUDIOLOGY & SPEECH-LANGUAGE PATHOLOGYOTORH-OTORHINOLARYNGOLOGY
CiteScore
4.50
自引率
11.10%
发文量
44
审稿时长
12 weeks
期刊介绍:
Trends in Hearing is an open access journal completely dedicated to publishing original research and reviews focusing on human hearing, hearing loss, hearing aids, auditory implants, and aural rehabilitation. Under its former name, Trends in Amplification, the journal established itself as a forum for concise explorations of all areas of translational hearing research by leaders in the field. Trends in Hearing has now expanded its focus to include original research articles, with the goal of becoming the premier venue for research related to human hearing and hearing loss.