描述闪烁光刺激时健康视网膜动脉扩张反应的时间过程

IF 1.8 4区 医学 Q3 PERIPHERAL VASCULAR DISEASE Journal of Vascular Research Pub Date : 2024-11-19 DOI:10.1159/000541443
Robert J Summers, Rebekka Heitmar
{"title":"描述闪烁光刺激时健康视网膜动脉扩张反应的时间过程","authors":"Robert J Summers, Rebekka Heitmar","doi":"10.1159/000541443","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The dilatory response of healthy retinal arterioles to flicker-light (FL) provocation appears to be biphasic. The vessel diameter rapidly increases (acute phase) over 5-10 s, then barely increases thereafter (maintenance phase) until FL cessation. This reaction is usually characterised at a single point by two parameters: maximum dilation (MD) relative to baseline diameter (MD, %) and time to MD (RT, s). This paper describes the biphasic reaction of retinal arteries during FL provocation using a bi-linear function.</p><p><strong>Methods: </strong>Retinal arterioles from 45 adults were examined during flicker provocation. Each individual time course of arterial diameter change during FL provocation was characterised by a bi-linear equation and compared with MD and RT.</p><p><strong>Results: </strong>Slopes of the acute phase were 0.506%/s, and the maintenance phase was nearly flat (0.012%/s). The mean time at which the reaction changed from acute to maintenance phase was 7.4 s which is significantly different from RT (16.0 s). Mean dilation at this point (2.987%) was significantly different from MD (3.734%), but it was still 80% of MD in less than half of RT.</p><p><strong>Conclusion: </strong>Bi-linear fitting parameters better characterises the arterial dilatory response than MD and RT. Further stratification of clinical groups using bi-linear fitting may provide insight of the underlying physiology of vessel dilation for different pathologies.</p>","PeriodicalId":17530,"journal":{"name":"Journal of Vascular Research","volume":" ","pages":"1-9"},"PeriodicalIF":1.8000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Characterising the Time Course of the Dilatory Response of Healthy Retinal Arteries during Flicker-Light Provocation.\",\"authors\":\"Robert J Summers, Rebekka Heitmar\",\"doi\":\"10.1159/000541443\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The dilatory response of healthy retinal arterioles to flicker-light (FL) provocation appears to be biphasic. The vessel diameter rapidly increases (acute phase) over 5-10 s, then barely increases thereafter (maintenance phase) until FL cessation. This reaction is usually characterised at a single point by two parameters: maximum dilation (MD) relative to baseline diameter (MD, %) and time to MD (RT, s). This paper describes the biphasic reaction of retinal arteries during FL provocation using a bi-linear function.</p><p><strong>Methods: </strong>Retinal arterioles from 45 adults were examined during flicker provocation. Each individual time course of arterial diameter change during FL provocation was characterised by a bi-linear equation and compared with MD and RT.</p><p><strong>Results: </strong>Slopes of the acute phase were 0.506%/s, and the maintenance phase was nearly flat (0.012%/s). The mean time at which the reaction changed from acute to maintenance phase was 7.4 s which is significantly different from RT (16.0 s). Mean dilation at this point (2.987%) was significantly different from MD (3.734%), but it was still 80% of MD in less than half of RT.</p><p><strong>Conclusion: </strong>Bi-linear fitting parameters better characterises the arterial dilatory response than MD and RT. Further stratification of clinical groups using bi-linear fitting may provide insight of the underlying physiology of vessel dilation for different pathologies.</p>\",\"PeriodicalId\":17530,\"journal\":{\"name\":\"Journal of Vascular Research\",\"volume\":\" \",\"pages\":\"1-9\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Vascular Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000541443\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vascular Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000541443","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

简介健康视网膜动脉对闪烁光(FL)刺激的扩张反应似乎是双相的。血管直径在 5-10 秒内迅速增大(急性期),之后几乎不再增大(维持期),直到 FL 停止。这种反应通常由两个参数来描述:相对于基线直径的最大扩张(MD)(MD,%)和达到 MD 的时间(RT,秒)。本文使用双线性函数描述了 FL 激发过程中视网膜动脉的双相反应:方法:对 45 名成人的视网膜动脉在闪烁激发时进行了检查。方法:在闪烁诱发过程中对 45 名成人的视网膜动脉血管进行检查,用双线性方程描述闪烁诱发过程中动脉直径变化的每个时间过程,并与 MD 和 RT 进行比较:结果:急性期的斜率为 0.506%/s,维持期几乎持平(0.012%/s)。反应从急性期转入维持期的平均时间为 7.4 秒,与 RT(16.0 秒)有显著差异。此时的平均扩张率(2.987%)与 MD(3.734%)有显著差异,但仍是 MD 的 80%,不到 RT 的一半:结论:与 MD 和 RT 相比,双线性拟合参数能更好地描述动脉扩张反应。结论:与 MD 和 RT 相比,双线性拟合参数能更好地描述动脉扩张反应,使用双线性拟合参数对临床群体进行进一步分层,可深入了解不同病理情况下血管扩张的潜在生理机制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Characterising the Time Course of the Dilatory Response of Healthy Retinal Arteries during Flicker-Light Provocation.

Introduction: The dilatory response of healthy retinal arterioles to flicker-light (FL) provocation appears to be biphasic. The vessel diameter rapidly increases (acute phase) over 5-10 s, then barely increases thereafter (maintenance phase) until FL cessation. This reaction is usually characterised at a single point by two parameters: maximum dilation (MD) relative to baseline diameter (MD, %) and time to MD (RT, s). This paper describes the biphasic reaction of retinal arteries during FL provocation using a bi-linear function.

Methods: Retinal arterioles from 45 adults were examined during flicker provocation. Each individual time course of arterial diameter change during FL provocation was characterised by a bi-linear equation and compared with MD and RT.

Results: Slopes of the acute phase were 0.506%/s, and the maintenance phase was nearly flat (0.012%/s). The mean time at which the reaction changed from acute to maintenance phase was 7.4 s which is significantly different from RT (16.0 s). Mean dilation at this point (2.987%) was significantly different from MD (3.734%), but it was still 80% of MD in less than half of RT.

Conclusion: Bi-linear fitting parameters better characterises the arterial dilatory response than MD and RT. Further stratification of clinical groups using bi-linear fitting may provide insight of the underlying physiology of vessel dilation for different pathologies.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Vascular Research
Journal of Vascular Research 医学-生理学
CiteScore
3.40
自引率
0.00%
发文量
25
审稿时长
>12 weeks
期刊介绍: The ''Journal of Vascular Research'' publishes original articles and reviews of scientific excellence in vascular and microvascular biology, physiology and pathophysiology. The scope of the journal covers a broad spectrum of vascular and lymphatic research, including vascular structure, vascular function, haemodynamics, mechanics, cell signalling, intercellular communication, growth and differentiation. JVR''s ''Vascular Update'' series regularly presents state-of-the-art reviews on hot topics in vascular biology. Manuscript processing times are, consistent with stringent review, kept as short as possible due to electronic submission. All articles are published online first, ensuring rapid publication. The ''Journal of Vascular Research'' is the official journal of the European Society for Microcirculation. A biennial prize is awarded to the authors of the best paper published in the journal over the previous two years, thus encouraging young scientists working in the exciting field of vascular biology to publish their findings.
期刊最新文献
RIP3 augments neuroinflammation by facilitating neutrophil infiltration during an ischemic stroke. Characterising the Time Course of the Dilatory Response of Healthy Retinal Arteries during Flicker-Light Provocation. Perfusion staining methods for visualization of the intact microvascular networks in whole mount skeletal muscle preparations. Cerebral Cortical Vasodilation via Nicotinic Receptors by Heated Tobacco Product Aerosol Extract in Rats. Rivaroxaban as a protector of Oxidative Stress-induced Vascular Endothelial Glycocalyx Damage via The IQGAP1/PAR1-2/PI3K/Akt Pathway.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1