Sofie Brouwers, Giulia Botti, Matthias Verbesselt, Lucio Addeo, Marta Belmonte, Kostas Bermpeis, Dario Tino Bertolone, Chiara Valeriano, Michele Mattia Viscusi, Eric Wyffels
{"title":"基于导管的肾脏去神经治疗难治性动脉高血压:10 年真实世界随访数据。","authors":"Sofie Brouwers, Giulia Botti, Matthias Verbesselt, Lucio Addeo, Marta Belmonte, Kostas Bermpeis, Dario Tino Bertolone, Chiara Valeriano, Michele Mattia Viscusi, Eric Wyffels","doi":"10.1111/jch.14931","DOIUrl":null,"url":null,"abstract":"<p><p>This analysis of real-world data examines the efficacy, safety, and long-term outcomes of renal denervation in hypertensive patients for up to 10 years. Sixty-five consecutive patients underwent renal denervation (RDN) (single operator) for uncontrolled resistant hypertension. Efficacy was defined as the interindividual change of office (OBPM) and ambulatory blood pressure monitoring (ABPM) at 1, 6, 12 months, 2-4 and 5-10 years after RDN. Medication changes, renal function, and device generation disparities were analyzed. Of these patients, 42 received RDN with a first-generation device, while 23 underwent the procedure with a second-generation device. Baseline demographics included a predominantly male cohort (57.6%) with an average age of 60.3 years. The mean number of medications at baseline was 4.3. OBPM at baseline was 169.0/87.4 mmHg, and ABPM at baseline was 153.4/88.4 mmHg. Post-procedure, significant reductions in systolic blood pressure (SBP) were observed in both OBPM and ABPM at 1 month (OBPM 147.9/82.8 mmHg; ABPM 141.3/83.0 mmHg [SBP, p < 0.001]), sustained up to 10 years (OBPM 153.1/84.3 mmHg; ABPM 138/80.1 mmHg [SBP, p < 0.001]). After 1 year around half of patients had a controlled OBPM and 24 h ABPM < 135/85 mmHg, which was associated with a higher number of ablation spots (31.5±14.8 vs. 15.5 ± 6.5, p = 0.002) and occurred more often when treated with a second-generation device (2 [12.5%] vs. 7 [77.8%], p = 0.002). Renal function displayed a minor physiological decline over 5-10 years. No major complication occurred. Renal denervation demonstrated sustained significant reductions in systolic OBPM and ABPM up to 10 years post-procedure. Controlled blood pressure at 1 year was associated with a higher number of mean ablated spots and the use of a second-generation device. The procedure exhibited a favorable safety profile, indicating its viability in managing hypertension without significant renal function compromise.</p>","PeriodicalId":50237,"journal":{"name":"Journal of Clinical Hypertension","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Catheter-Based Renal Denervation for Resistant Arterial Hypertension: 10-Year Real-World Follow-Up Data.\",\"authors\":\"Sofie Brouwers, Giulia Botti, Matthias Verbesselt, Lucio Addeo, Marta Belmonte, Kostas Bermpeis, Dario Tino Bertolone, Chiara Valeriano, Michele Mattia Viscusi, Eric Wyffels\",\"doi\":\"10.1111/jch.14931\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This analysis of real-world data examines the efficacy, safety, and long-term outcomes of renal denervation in hypertensive patients for up to 10 years. Sixty-five consecutive patients underwent renal denervation (RDN) (single operator) for uncontrolled resistant hypertension. Efficacy was defined as the interindividual change of office (OBPM) and ambulatory blood pressure monitoring (ABPM) at 1, 6, 12 months, 2-4 and 5-10 years after RDN. Medication changes, renal function, and device generation disparities were analyzed. Of these patients, 42 received RDN with a first-generation device, while 23 underwent the procedure with a second-generation device. Baseline demographics included a predominantly male cohort (57.6%) with an average age of 60.3 years. The mean number of medications at baseline was 4.3. OBPM at baseline was 169.0/87.4 mmHg, and ABPM at baseline was 153.4/88.4 mmHg. Post-procedure, significant reductions in systolic blood pressure (SBP) were observed in both OBPM and ABPM at 1 month (OBPM 147.9/82.8 mmHg; ABPM 141.3/83.0 mmHg [SBP, p < 0.001]), sustained up to 10 years (OBPM 153.1/84.3 mmHg; ABPM 138/80.1 mmHg [SBP, p < 0.001]). After 1 year around half of patients had a controlled OBPM and 24 h ABPM < 135/85 mmHg, which was associated with a higher number of ablation spots (31.5±14.8 vs. 15.5 ± 6.5, p = 0.002) and occurred more often when treated with a second-generation device (2 [12.5%] vs. 7 [77.8%], p = 0.002). Renal function displayed a minor physiological decline over 5-10 years. No major complication occurred. Renal denervation demonstrated sustained significant reductions in systolic OBPM and ABPM up to 10 years post-procedure. Controlled blood pressure at 1 year was associated with a higher number of mean ablated spots and the use of a second-generation device. The procedure exhibited a favorable safety profile, indicating its viability in managing hypertension without significant renal function compromise.</p>\",\"PeriodicalId\":50237,\"journal\":{\"name\":\"Journal of Clinical Hypertension\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Hypertension\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/jch.14931\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Hypertension","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jch.14931","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
This analysis of real-world data examines the efficacy, safety, and long-term outcomes of renal denervation in hypertensive patients for up to 10 years. Sixty-five consecutive patients underwent renal denervation (RDN) (single operator) for uncontrolled resistant hypertension. Efficacy was defined as the interindividual change of office (OBPM) and ambulatory blood pressure monitoring (ABPM) at 1, 6, 12 months, 2-4 and 5-10 years after RDN. Medication changes, renal function, and device generation disparities were analyzed. Of these patients, 42 received RDN with a first-generation device, while 23 underwent the procedure with a second-generation device. Baseline demographics included a predominantly male cohort (57.6%) with an average age of 60.3 years. The mean number of medications at baseline was 4.3. OBPM at baseline was 169.0/87.4 mmHg, and ABPM at baseline was 153.4/88.4 mmHg. Post-procedure, significant reductions in systolic blood pressure (SBP) were observed in both OBPM and ABPM at 1 month (OBPM 147.9/82.8 mmHg; ABPM 141.3/83.0 mmHg [SBP, p < 0.001]), sustained up to 10 years (OBPM 153.1/84.3 mmHg; ABPM 138/80.1 mmHg [SBP, p < 0.001]). After 1 year around half of patients had a controlled OBPM and 24 h ABPM < 135/85 mmHg, which was associated with a higher number of ablation spots (31.5±14.8 vs. 15.5 ± 6.5, p = 0.002) and occurred more often when treated with a second-generation device (2 [12.5%] vs. 7 [77.8%], p = 0.002). Renal function displayed a minor physiological decline over 5-10 years. No major complication occurred. Renal denervation demonstrated sustained significant reductions in systolic OBPM and ABPM up to 10 years post-procedure. Controlled blood pressure at 1 year was associated with a higher number of mean ablated spots and the use of a second-generation device. The procedure exhibited a favorable safety profile, indicating its viability in managing hypertension without significant renal function compromise.
期刊介绍:
The Journal of Clinical Hypertension is a peer-reviewed, monthly publication that serves internists, cardiologists, nephrologists, endocrinologists, hypertension specialists, primary care practitioners, pharmacists and all professionals interested in hypertension by providing objective, up-to-date information and practical recommendations on the full range of clinical aspects of hypertension. Commentaries and columns by experts in the field provide further insights into our original research articles as well as on major articles published elsewhere. Major guidelines for the management of hypertension are also an important feature of the Journal. Through its partnership with the World Hypertension League, JCH will include a new focus on hypertension and public health, including major policy issues, that features research and reviews related to disease characteristics and management at the population level.