{"title":"根据故障位置检查定向过流保护器协调细节的图形工具","authors":"Paulo M. De Oliveira-De Jesus;Elmer Sorrentino","doi":"10.1109/TPWRD.2024.3504133","DOIUrl":null,"url":null,"abstract":"This letter describes a novel graphical tool that was developed to check the coordination details of directional overcurrent protections (67) as a function of the fault location. The tool considers transient configurations due to sequential trips at both line-ends, and shows three important issues of coordination for each fault location: a) separation between operation times of main and backup 67s; b) currents seen by each 67 prior to and after the trip of the first circuit breaker; c) possible loss-of-sensitivity of backup 67s due to the pickup setting or due to direction of current. A previously developed simulator performs the calculations, using 1000 fault locations for each protected line, and it is complemented by the proposed graphical tool.","PeriodicalId":13498,"journal":{"name":"IEEE Transactions on Power Delivery","volume":"40 1","pages":"659-662"},"PeriodicalIF":3.8000,"publicationDate":"2024-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Graphical Tool to Examine the Coordination Details of Directional Overcurrent Protections as a Function of Fault Location\",\"authors\":\"Paulo M. De Oliveira-De Jesus;Elmer Sorrentino\",\"doi\":\"10.1109/TPWRD.2024.3504133\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This letter describes a novel graphical tool that was developed to check the coordination details of directional overcurrent protections (67) as a function of the fault location. The tool considers transient configurations due to sequential trips at both line-ends, and shows three important issues of coordination for each fault location: a) separation between operation times of main and backup 67s; b) currents seen by each 67 prior to and after the trip of the first circuit breaker; c) possible loss-of-sensitivity of backup 67s due to the pickup setting or due to direction of current. A previously developed simulator performs the calculations, using 1000 fault locations for each protected line, and it is complemented by the proposed graphical tool.\",\"PeriodicalId\":13498,\"journal\":{\"name\":\"IEEE Transactions on Power Delivery\",\"volume\":\"40 1\",\"pages\":\"659-662\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-11-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Power Delivery\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10759830/\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Power Delivery","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10759830/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
A Graphical Tool to Examine the Coordination Details of Directional Overcurrent Protections as a Function of Fault Location
This letter describes a novel graphical tool that was developed to check the coordination details of directional overcurrent protections (67) as a function of the fault location. The tool considers transient configurations due to sequential trips at both line-ends, and shows three important issues of coordination for each fault location: a) separation between operation times of main and backup 67s; b) currents seen by each 67 prior to and after the trip of the first circuit breaker; c) possible loss-of-sensitivity of backup 67s due to the pickup setting or due to direction of current. A previously developed simulator performs the calculations, using 1000 fault locations for each protected line, and it is complemented by the proposed graphical tool.
期刊介绍:
The scope of the Society embraces planning, research, development, design, application, construction, installation and operation of apparatus, equipment, structures, materials and systems for the safe, reliable and economic generation, transmission, distribution, conversion, measurement and control of electric energy. It includes the developing of engineering standards, the providing of information and instruction to the public and to legislators, as well as technical scientific, literary, educational and other activities that contribute to the electric power discipline or utilize the techniques or products within this discipline.