使用动态磁共振成像评估所谓的颅内节律性冲动(CRI)的适用性。

IF 2.2 3区 医学 Q2 ORTHOPEDICS BMC Musculoskeletal Disorders Pub Date : 2024-11-21 DOI:10.1186/s12891-024-08064-y
Pezhman Masoudi, Noureddin Karimi, Iraj Abdollahi, Enayatollah Bakhshi, Saeideh Moravej, Ahmad Aghazadeh
{"title":"使用动态磁共振成像评估所谓的颅内节律性冲动(CRI)的适用性。","authors":"Pezhman Masoudi, Noureddin Karimi, Iraj Abdollahi, Enayatollah Bakhshi, Saeideh Moravej, Ahmad Aghazadeh","doi":"10.1186/s12891-024-08064-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the feasibility of using dynamic MRI to measure the features of cranial rhythmic impulse (CRI).</p><p><strong>Design and setting: </strong>Fifteen healthy participants (9 females and 6 males, aged 25 to 77) underwent dynamic MRI in a sagittal T2 HASTE view at a rate of 0.60 Hz for 30 s. The MRI videos were analyzed using video tracking software. Three points were marked: the glabella, the midpoint of the sella turcica, and a symmetrical point of the glabella on the occiput. The distances between these points were measured across 46 frames. Amplitudes and rates of asymmetrical CRI waves were calculated using Excel formulas.</p><p><strong>Results: </strong>The mean wave frequencies were 5.65 Hz for the anteroposterior distance, 6.2 Hz from sella turcica to occiput, and 6.76 Hz from sella turcica to glabella. The mean wave amplitudes were 0.39 mm, 0.6 mm, and 0.49 mm for the respective distances. Both intraclass correlation coefficients (ICC) and reliability coefficient (R) indicated excellent reliability (R, ICC > 0.90). The technical error of measurement (TEM) exceeded 1 mm for the anteroposterior and sella-to-occiput distances, while it was 0.32 mm for the sella-to-glabella distance.</p><p><strong>Conclusions: </strong>Dynamic MRI demonstrates potential in measuring the features of CRI, particularly in assessing CRI wave rate. While the ICC values indicate high reliability, the TEM values suggest that using MRI to measure CRI wave amplitude may only be dependable for the distance from the sella to the glabella.</p>","PeriodicalId":9189,"journal":{"name":"BMC Musculoskeletal Disorders","volume":"25 1","pages":"941"},"PeriodicalIF":2.2000,"publicationDate":"2024-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11580391/pdf/","citationCount":"0","resultStr":"{\"title\":\"Applicability of using dynamic MRI to evaluate alleged cranial rhythmic impulse (CRI).\",\"authors\":\"Pezhman Masoudi, Noureddin Karimi, Iraj Abdollahi, Enayatollah Bakhshi, Saeideh Moravej, Ahmad Aghazadeh\",\"doi\":\"10.1186/s12891-024-08064-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To evaluate the feasibility of using dynamic MRI to measure the features of cranial rhythmic impulse (CRI).</p><p><strong>Design and setting: </strong>Fifteen healthy participants (9 females and 6 males, aged 25 to 77) underwent dynamic MRI in a sagittal T2 HASTE view at a rate of 0.60 Hz for 30 s. The MRI videos were analyzed using video tracking software. Three points were marked: the glabella, the midpoint of the sella turcica, and a symmetrical point of the glabella on the occiput. The distances between these points were measured across 46 frames. Amplitudes and rates of asymmetrical CRI waves were calculated using Excel formulas.</p><p><strong>Results: </strong>The mean wave frequencies were 5.65 Hz for the anteroposterior distance, 6.2 Hz from sella turcica to occiput, and 6.76 Hz from sella turcica to glabella. The mean wave amplitudes were 0.39 mm, 0.6 mm, and 0.49 mm for the respective distances. Both intraclass correlation coefficients (ICC) and reliability coefficient (R) indicated excellent reliability (R, ICC > 0.90). The technical error of measurement (TEM) exceeded 1 mm for the anteroposterior and sella-to-occiput distances, while it was 0.32 mm for the sella-to-glabella distance.</p><p><strong>Conclusions: </strong>Dynamic MRI demonstrates potential in measuring the features of CRI, particularly in assessing CRI wave rate. While the ICC values indicate high reliability, the TEM values suggest that using MRI to measure CRI wave amplitude may only be dependable for the distance from the sella to the glabella.</p>\",\"PeriodicalId\":9189,\"journal\":{\"name\":\"BMC Musculoskeletal Disorders\",\"volume\":\"25 1\",\"pages\":\"941\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-11-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11580391/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Musculoskeletal Disorders\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12891-024-08064-y\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Musculoskeletal Disorders","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12891-024-08064-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估使用动态磁共振成像测量颅内节律性冲动(CRI)特征的可行性:评估使用动态磁共振成像测量颅内节律性冲动(CRI)特征的可行性:15 名健康参与者(9 名女性和 6 名男性,年龄在 25 至 77 岁之间)在矢状 T2 HASTE 视图中以 0.60 Hz 的频率进行了 30 秒的动态 MRI 扫描。标记了三个点:髌骨、蝶骨中点和枕骨上髌骨的对称点。这些点之间的距离在 46 帧图像中进行测量。使用 Excel 公式计算不对称 CRI 波的振幅和频率:结果:前胸距离的平均波频为 5.65 Hz,从肩胛骨到枕骨的平均波频为 6.2 Hz,从肩胛骨到枕骨的平均波频为 6.76 Hz。各距离的平均波幅分别为 0.39 毫米、0.6 毫米和 0.49 毫米。类内相关系数(ICC)和可靠性系数(R)均显示出极佳的可靠性(R、ICC > 0.90)。前胸距离和蝶骨至枕骨距离的技术测量误差(TEM)超过1毫米,而蝶骨至盂的距离为0.32毫米:动态磁共振成像在测量CRI特征,尤其是评估CRI波率方面具有潜力。虽然 ICC 值表明可信度很高,但 TEM 值表明,使用 MRI 测量 CRI 波幅可能只对脊柱到髌骨的距离可靠。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Applicability of using dynamic MRI to evaluate alleged cranial rhythmic impulse (CRI).

Objectives: To evaluate the feasibility of using dynamic MRI to measure the features of cranial rhythmic impulse (CRI).

Design and setting: Fifteen healthy participants (9 females and 6 males, aged 25 to 77) underwent dynamic MRI in a sagittal T2 HASTE view at a rate of 0.60 Hz for 30 s. The MRI videos were analyzed using video tracking software. Three points were marked: the glabella, the midpoint of the sella turcica, and a symmetrical point of the glabella on the occiput. The distances between these points were measured across 46 frames. Amplitudes and rates of asymmetrical CRI waves were calculated using Excel formulas.

Results: The mean wave frequencies were 5.65 Hz for the anteroposterior distance, 6.2 Hz from sella turcica to occiput, and 6.76 Hz from sella turcica to glabella. The mean wave amplitudes were 0.39 mm, 0.6 mm, and 0.49 mm for the respective distances. Both intraclass correlation coefficients (ICC) and reliability coefficient (R) indicated excellent reliability (R, ICC > 0.90). The technical error of measurement (TEM) exceeded 1 mm for the anteroposterior and sella-to-occiput distances, while it was 0.32 mm for the sella-to-glabella distance.

Conclusions: Dynamic MRI demonstrates potential in measuring the features of CRI, particularly in assessing CRI wave rate. While the ICC values indicate high reliability, the TEM values suggest that using MRI to measure CRI wave amplitude may only be dependable for the distance from the sella to the glabella.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Musculoskeletal Disorders
BMC Musculoskeletal Disorders 医学-风湿病学
CiteScore
3.80
自引率
8.70%
发文量
1017
审稿时长
3-6 weeks
期刊介绍: BMC Musculoskeletal Disorders is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of musculoskeletal disorders, as well as related molecular genetics, pathophysiology, and epidemiology. The scope of the Journal covers research into rheumatic diseases where the primary focus relates specifically to a component(s) of the musculoskeletal system.
期刊最新文献
Modified scarf osteotomy has a possible capability to be indicated against very severe hallux valgus deformity. Risk factors for acetabular fracture treatment failure: a systematic review and meta-analysis. Validity evaluation of a rat model of monoiodoacetate-induced osteoarthritis with clinically effective drugs. Comparing effectiveness of 3-needle approach versus 5-needle approach of genicular nerve block on pain and quality of life in chronic osteoarthritis of knee: a double blinded randomised controlled trial. Associations between folate intake and knee pain, inflammation mediators and comorbid conditions in patients with symptomatic knee osteoarthritis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1