通过经直肠超声预测高剂量率前列腺近距离放射治疗的即时计划质量。

Brachytherapy Pub Date : 2025-01-01 Epub Date: 2024-11-20 DOI:10.1016/j.brachy.2024.10.009
Tonghe Wang, Yining Feng, Joel Beaudry, David Aramburu Nunez, Daniel Gorovets, Marisa Kollmeier, Antonio L Damato
{"title":"通过经直肠超声预测高剂量率前列腺近距离放射治疗的即时计划质量。","authors":"Tonghe Wang, Yining Feng, Joel Beaudry, David Aramburu Nunez, Daniel Gorovets, Marisa Kollmeier, Antonio L Damato","doi":"10.1016/j.brachy.2024.10.009","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We investigated the feasibility of AI to provide an instant feedback of the potential plan quality based on live needle placement, and before planning is initiated.</p><p><strong>Materials and methods: </strong>We utilized YOLOv8 to perform automatic organ segmentation and needle detection on 2D transrectal ultrasound images. The segmentation and detection results for each patient were then fed into a plan quality prediction model based on ResNet101. Its outputs are values of selected dose volume metrics. Imaging and plan data from 504 prostate HDR boost patients (456 for training, 24 for validation, and 24 for testing) treated in our clinic were included in this study. The segmentation, needle detection, and prediction results were compared to the clinical results (ground truth).</p><p><strong>Results: </strong>For prediction model, the p-values of t-test between the predicted values and ground truth for either rectum D2cc or urethra D20% were larger than 0.8. The sensitivity of prediction model in finding implant geometries resulting in below-median rectum D2cc and urethra D20% were 83% and 87%.</p><p><strong>Conclusion: </strong>The proposed method has great potential to facilitate the current prostate HDR brachytherapy workflows by providing valuable feedback during needle insertion, and facilitating decision making of where and if additional needles are required.</p>","PeriodicalId":93914,"journal":{"name":"Brachytherapy","volume":" ","pages":"171-176"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11738656/pdf/","citationCount":"0","resultStr":"{\"title\":\"Instant plan quality prediction on transrectal ultrasound for high-dose-rate prostate brachytherapy.\",\"authors\":\"Tonghe Wang, Yining Feng, Joel Beaudry, David Aramburu Nunez, Daniel Gorovets, Marisa Kollmeier, Antonio L Damato\",\"doi\":\"10.1016/j.brachy.2024.10.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>We investigated the feasibility of AI to provide an instant feedback of the potential plan quality based on live needle placement, and before planning is initiated.</p><p><strong>Materials and methods: </strong>We utilized YOLOv8 to perform automatic organ segmentation and needle detection on 2D transrectal ultrasound images. The segmentation and detection results for each patient were then fed into a plan quality prediction model based on ResNet101. Its outputs are values of selected dose volume metrics. Imaging and plan data from 504 prostate HDR boost patients (456 for training, 24 for validation, and 24 for testing) treated in our clinic were included in this study. The segmentation, needle detection, and prediction results were compared to the clinical results (ground truth).</p><p><strong>Results: </strong>For prediction model, the p-values of t-test between the predicted values and ground truth for either rectum D2cc or urethra D20% were larger than 0.8. The sensitivity of prediction model in finding implant geometries resulting in below-median rectum D2cc and urethra D20% were 83% and 87%.</p><p><strong>Conclusion: </strong>The proposed method has great potential to facilitate the current prostate HDR brachytherapy workflows by providing valuable feedback during needle insertion, and facilitating decision making of where and if additional needles are required.</p>\",\"PeriodicalId\":93914,\"journal\":{\"name\":\"Brachytherapy\",\"volume\":\" \",\"pages\":\"171-176\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11738656/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Brachytherapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1016/j.brachy.2024.10.009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/11/20 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brachytherapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.brachy.2024.10.009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/20 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:我们研究了人工智能的可行性,它能在计划开始前,根据实时置针情况即时反馈潜在计划的质量:我们利用 YOLOv8 对二维经直肠超声图像进行自动器官分割和针检测。然后将每位患者的分割和检测结果输入基于 ResNet101 的计划质量预测模型。其输出是选定的剂量体积指标值。本研究包括本诊所治疗的 504 名前列腺 HDR 提升患者(456 名用于训练,24 名用于验证,24 名用于测试)的成像和计划数据。将分割、针检测和预测结果与临床结果(地面实况)进行了比较:结果:对于预测模型,直肠 D2cc 或尿道 D20% 的预测值与地面实况之间的 t 检验 p 值均大于 0.8。预测模型在找到导致直肠 D2cc 和尿道 D20% 低于中线的种植体几何形状方面的灵敏度分别为 83% 和 87%:所提出的方法在前列腺 HDR 近距离放射治疗工作流程中大有可为,它能在穿刺针插入过程中提供有价值的反馈,并有助于决定在何处以及是否需要额外的穿刺针。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Instant plan quality prediction on transrectal ultrasound for high-dose-rate prostate brachytherapy.

Purpose: We investigated the feasibility of AI to provide an instant feedback of the potential plan quality based on live needle placement, and before planning is initiated.

Materials and methods: We utilized YOLOv8 to perform automatic organ segmentation and needle detection on 2D transrectal ultrasound images. The segmentation and detection results for each patient were then fed into a plan quality prediction model based on ResNet101. Its outputs are values of selected dose volume metrics. Imaging and plan data from 504 prostate HDR boost patients (456 for training, 24 for validation, and 24 for testing) treated in our clinic were included in this study. The segmentation, needle detection, and prediction results were compared to the clinical results (ground truth).

Results: For prediction model, the p-values of t-test between the predicted values and ground truth for either rectum D2cc or urethra D20% were larger than 0.8. The sensitivity of prediction model in finding implant geometries resulting in below-median rectum D2cc and urethra D20% were 83% and 87%.

Conclusion: The proposed method has great potential to facilitate the current prostate HDR brachytherapy workflows by providing valuable feedback during needle insertion, and facilitating decision making of where and if additional needles are required.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Quality control study of cervical cancer interstitial brachytherapy treatment plans using statistical process control. 3D-printed radiopaque episcleral plaques with radioactive collimating cavities for enhanced dose delivery in brachytherapy. Ultrasound and CT-guided implantation of iodine-125 seeds combined with transarterial chemoembolization for recurrent hepatocellular carcinoma at complex sites after hepatectomy. HDR brachytherapy combined with external beam radiotherapy for unfavorable localized prostate cancer: A single center experience from inception to standard of care. From patient to pioneer: The inspiring journey of Dr. Brian Moran.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1