利用顶空气氧分析法对低温条件下储存的小瓶进行容器封闭完整性测试方法。

Allison Alix Caudill, Ken Victor, James Veale
{"title":"利用顶空气氧分析法对低温条件下储存的小瓶进行容器封闭完整性测试方法。","authors":"Allison Alix Caudill, Ken Victor, James Veale","doi":"10.5731/pdajpst.2022.012813","DOIUrl":null,"url":null,"abstract":"<p><p>An increasing number of pharmaceutical products require deep cold storage at cryogenic conditions, approximately -150°C to -190°C, to maintain stability and/or activity. Previous work has revealed that, at these extreme conditions, a typical pharmaceutical package configuration (vial, stopper, crimp cap) may lose container closure integrity (CCI) due to both the glass transition temperature (-55°C to -70°C) of the rubber stopper used to seal the vial and the different thermal expansion coefficients of the primary packaging components. Importantly, this type of temporary breach in CCI frequently reseals itself when the vial is brought back to ambient temperature. The following study illustrates a CCI test method using laser-based headspace oxygen analysis for identifying both temporary and permanent defects in vial assemblies exposed to cryogenic storage conditions. The method takes advantage of the nitrogen-enriched environment that exists in most cryogenic storage conditions. When vials are placed into cryogenic storage, the cold temperature creates a pressure gradient across the vial seal that, if a leak defect develops, drives nitrogen gas into the vial headspace and, thereby, decreases the headspace oxygen concentration for vials originally packaged with an air headspace. This decrease in headspace oxygen after the cryogenic storage period can be used to identify a breach in CCI, regardless of whether the defect is temporary or permanent. Experimental data obtained for three different vial types (a 2R glass vial, a 2mL plastic CZ vial, and a 2mL plastic Aseptic Technologies [AT] vial) demonstrated that this CCI test method can robustly and readily detect laser-drilled micron-sized positive controls down to 5 μm (the smallest defect size tested) in the body of the vial and type controls prepared using a Ø64 µm wire at the stopper-seal interface (effective defect size varied depending on the vial).</p>","PeriodicalId":19986,"journal":{"name":"PDA Journal of Pharmaceutical Science and Technology","volume":" ","pages":"707-729"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Container Closure Integrity Test Method for Vials Stored at Cryogenic Conditions Using Headspace Oxygen Analysis.\",\"authors\":\"Allison Alix Caudill, Ken Victor, James Veale\",\"doi\":\"10.5731/pdajpst.2022.012813\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An increasing number of pharmaceutical products require deep cold storage at cryogenic conditions, approximately -150°C to -190°C, to maintain stability and/or activity. Previous work has revealed that, at these extreme conditions, a typical pharmaceutical package configuration (vial, stopper, crimp cap) may lose container closure integrity (CCI) due to both the glass transition temperature (-55°C to -70°C) of the rubber stopper used to seal the vial and the different thermal expansion coefficients of the primary packaging components. Importantly, this type of temporary breach in CCI frequently reseals itself when the vial is brought back to ambient temperature. The following study illustrates a CCI test method using laser-based headspace oxygen analysis for identifying both temporary and permanent defects in vial assemblies exposed to cryogenic storage conditions. The method takes advantage of the nitrogen-enriched environment that exists in most cryogenic storage conditions. When vials are placed into cryogenic storage, the cold temperature creates a pressure gradient across the vial seal that, if a leak defect develops, drives nitrogen gas into the vial headspace and, thereby, decreases the headspace oxygen concentration for vials originally packaged with an air headspace. This decrease in headspace oxygen after the cryogenic storage period can be used to identify a breach in CCI, regardless of whether the defect is temporary or permanent. Experimental data obtained for three different vial types (a 2R glass vial, a 2mL plastic CZ vial, and a 2mL plastic Aseptic Technologies [AT] vial) demonstrated that this CCI test method can robustly and readily detect laser-drilled micron-sized positive controls down to 5 μm (the smallest defect size tested) in the body of the vial and type controls prepared using a Ø64 µm wire at the stopper-seal interface (effective defect size varied depending on the vial).</p>\",\"PeriodicalId\":19986,\"journal\":{\"name\":\"PDA Journal of Pharmaceutical Science and Technology\",\"volume\":\" \",\"pages\":\"707-729\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PDA Journal of Pharmaceutical Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5731/pdajpst.2022.012813\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PDA Journal of Pharmaceutical Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5731/pdajpst.2022.012813","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

越来越多的药品需要在约 -150°C 至 -190°C 的低温条件下进行深度冷藏,以保持稳定性和/或活性。以前的研究表明,在这些极端条件下,由于用于密封小瓶的橡胶塞的玻璃化温度(-55°C 至 -70°C)和主要包装部件的不同热膨胀系数,典型的药品包装配置(小瓶、瓶塞、卷边帽)可能会失去容器封闭完整性(CCI)。重要的是,当小瓶恢复到环境温度时,CCI 中的这种暂时性裂口经常会自行愈合。下面的研究说明了一种 CCI 测试方法,该方法利用基于激光的顶空气氧分析来识别暴露在低温储存条件下的小瓶组件中的暂时性和永久性缺陷。该方法利用了大多数低温储存条件下的富氮环境。当小瓶被放入低温贮藏室时,低温会在小瓶密封处产生压力梯度,如果出现泄漏缺陷,氮气会进入小瓶顶空,从而降低原本以空气顶空包装的小瓶的顶空氧气浓度。低温贮藏期后顶空氧气浓度的降低可用于识别 CCI 的破损,无论该缺陷是暂时的还是永久的。对三种不同类型的小瓶(2R 玻璃小瓶、2 mL 塑料 CZ 小瓶和 2 mL 塑料无菌技术(AT)小瓶)所获得的实验数据表明,这种 CCI 检测方法可以稳健、轻松地检测到小瓶瓶身中 5 μm(所测试的最小缺陷尺寸)以下的激光钻孔微米级阳性对照物,以及在瓶塞-密封界面上使用直径为 64 μm 的金属丝制备的类型对照物(有效缺陷尺寸因小瓶而异)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Container Closure Integrity Test Method for Vials Stored at Cryogenic Conditions Using Headspace Oxygen Analysis.

An increasing number of pharmaceutical products require deep cold storage at cryogenic conditions, approximately -150°C to -190°C, to maintain stability and/or activity. Previous work has revealed that, at these extreme conditions, a typical pharmaceutical package configuration (vial, stopper, crimp cap) may lose container closure integrity (CCI) due to both the glass transition temperature (-55°C to -70°C) of the rubber stopper used to seal the vial and the different thermal expansion coefficients of the primary packaging components. Importantly, this type of temporary breach in CCI frequently reseals itself when the vial is brought back to ambient temperature. The following study illustrates a CCI test method using laser-based headspace oxygen analysis for identifying both temporary and permanent defects in vial assemblies exposed to cryogenic storage conditions. The method takes advantage of the nitrogen-enriched environment that exists in most cryogenic storage conditions. When vials are placed into cryogenic storage, the cold temperature creates a pressure gradient across the vial seal that, if a leak defect develops, drives nitrogen gas into the vial headspace and, thereby, decreases the headspace oxygen concentration for vials originally packaged with an air headspace. This decrease in headspace oxygen after the cryogenic storage period can be used to identify a breach in CCI, regardless of whether the defect is temporary or permanent. Experimental data obtained for three different vial types (a 2R glass vial, a 2mL plastic CZ vial, and a 2mL plastic Aseptic Technologies [AT] vial) demonstrated that this CCI test method can robustly and readily detect laser-drilled micron-sized positive controls down to 5 μm (the smallest defect size tested) in the body of the vial and type controls prepared using a Ø64 µm wire at the stopper-seal interface (effective defect size varied depending on the vial).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
34
期刊最新文献
Addressing Medical Device Extractables and Leachables via Non-Target Analysis (NTA); The Analytical Evaluation Threshold (AET) and Quantitation. Definition of particle visibility threshold in parenteral drug products - towards standardization of visual inspection operator qualification. Recommendations for Artificial Intelligence Application in Continued Process Verification. Comparing Container Closure Integrity Test Methods-Performance of Headspace Carbon Dioxide Analysis versus Helium Leakage Using Positive Controls. Case Studies on Changes and Proposed Process Development Approaches Reflecting Applicability of PDA Technical Report No. 89: Strategies for Vaccine Development and Lifecycle Management.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1