在接受过同质化治疗的疑似心脏肉样瘤病患者队列中评估重复 PET 成像对治疗反应和心血管结果的影响。

IF 3 4区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of Nuclear Cardiology Pub Date : 2024-11-21 DOI:10.1016/j.nuclcard.2024.102082
Chaitanya Rojulpote, Abhijit Bhattaru, Shivaraj Patil, Sarah L Adams, Jonathan A Salas, Mahesh K Vidula, Raul Porto Perez, Wumesh Kc, Karen Patterson, Caitlin B Clancy, Milton Rossman, Lee Goldberg, Paco E Bravo
{"title":"在接受过同质化治疗的疑似心脏肉样瘤病患者队列中评估重复 PET 成像对治疗反应和心血管结果的影响。","authors":"Chaitanya Rojulpote, Abhijit Bhattaru, Shivaraj Patil, Sarah L Adams, Jonathan A Salas, Mahesh K Vidula, Raul Porto Perez, Wumesh Kc, Karen Patterson, Caitlin B Clancy, Milton Rossman, Lee Goldberg, Paco E Bravo","doi":"10.1016/j.nuclcard.2024.102082","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Serial PET imaging is routinely employed to monitor treatment response in patients with suspected cardiac sarcoidosis (CS). Corticosteroids remain the mainstay of therapy in CS. However, there are no data available on the cardiovascular outcomes and optimal timing interval to obtain repeat PET while factoring in the influence of corticosteroid taper in relation to surveillance imaging.</p><p><strong>Methods: </strong>We identified 81 patients with suspected CS (Age: 56.3 ± 1.9, 67% male, LVEF 46.5 ± 3) who were treatment naïve and demonstrated inflammation on baseline PET, subsequently started on moderate-dose prednisone monotherapy (i.e., 30-40 mg/day), and had a diagnostic follow-up PET. Treatment response was graded as complete (CTR) or partial (PTR), and no-response (NTR). Patients were divided into tertiles based on follow-up time between PET scans; tertile-1 (<3.2 months; median 3.1 months), tertile-2 (3.2 - 6.8 months; median 5.9 months), and tertile-3 (>6.8 months; median 9.8 months). Corticosteroid taper was captured by measuring weekly changes in prednisone from start of treatment to up to one-year follow-up. Major adverse cardiovascular events (MACE), defined as sustained ventricular arrhythmias were documented during the first year post-baseline PET.</p><p><strong>Results: </strong>Treatment response CTR/PTR/NTR rates were similar across tertiles: (tertile-1 (92%) vs tertile-2 (86.2%) vs tertile-3 (85.2%); p=0.76). Taper rates and one-year cumulative prednisone dose were similar between the three groups (P=0.9). No significant difference was found in short-term MACE between the tertile groups (p=0.89). Similarly, MACE did not differ significantly according to treatment response status (p=0.39).</p><p><strong>Conclusion: </strong>Surveillance time and taper rates do not seem to influence treatment response on PET scans among patients initiated on moderate-dose prednisone only. Similar MACE rates were observed despite variations in follow-up time and treatment response status.</p>","PeriodicalId":16476,"journal":{"name":"Journal of Nuclear Cardiology","volume":" ","pages":"102082"},"PeriodicalIF":3.0000,"publicationDate":"2024-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessing the Effect of Repeat PET Imaging on Treatment Response and Cardiovascular Outcomes among a Homogenously Treated Cohort of Patients with Suspected Cardiac Sarcoidosis.\",\"authors\":\"Chaitanya Rojulpote, Abhijit Bhattaru, Shivaraj Patil, Sarah L Adams, Jonathan A Salas, Mahesh K Vidula, Raul Porto Perez, Wumesh Kc, Karen Patterson, Caitlin B Clancy, Milton Rossman, Lee Goldberg, Paco E Bravo\",\"doi\":\"10.1016/j.nuclcard.2024.102082\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Serial PET imaging is routinely employed to monitor treatment response in patients with suspected cardiac sarcoidosis (CS). Corticosteroids remain the mainstay of therapy in CS. However, there are no data available on the cardiovascular outcomes and optimal timing interval to obtain repeat PET while factoring in the influence of corticosteroid taper in relation to surveillance imaging.</p><p><strong>Methods: </strong>We identified 81 patients with suspected CS (Age: 56.3 ± 1.9, 67% male, LVEF 46.5 ± 3) who were treatment naïve and demonstrated inflammation on baseline PET, subsequently started on moderate-dose prednisone monotherapy (i.e., 30-40 mg/day), and had a diagnostic follow-up PET. Treatment response was graded as complete (CTR) or partial (PTR), and no-response (NTR). Patients were divided into tertiles based on follow-up time between PET scans; tertile-1 (<3.2 months; median 3.1 months), tertile-2 (3.2 - 6.8 months; median 5.9 months), and tertile-3 (>6.8 months; median 9.8 months). Corticosteroid taper was captured by measuring weekly changes in prednisone from start of treatment to up to one-year follow-up. Major adverse cardiovascular events (MACE), defined as sustained ventricular arrhythmias were documented during the first year post-baseline PET.</p><p><strong>Results: </strong>Treatment response CTR/PTR/NTR rates were similar across tertiles: (tertile-1 (92%) vs tertile-2 (86.2%) vs tertile-3 (85.2%); p=0.76). Taper rates and one-year cumulative prednisone dose were similar between the three groups (P=0.9). No significant difference was found in short-term MACE between the tertile groups (p=0.89). Similarly, MACE did not differ significantly according to treatment response status (p=0.39).</p><p><strong>Conclusion: </strong>Surveillance time and taper rates do not seem to influence treatment response on PET scans among patients initiated on moderate-dose prednisone only. Similar MACE rates were observed despite variations in follow-up time and treatment response status.</p>\",\"PeriodicalId\":16476,\"journal\":{\"name\":\"Journal of Nuclear Cardiology\",\"volume\":\" \",\"pages\":\"102082\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-11-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Nuclear Cardiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.nuclcard.2024.102082\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nuclear Cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.nuclcard.2024.102082","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

简介:对疑似心脏肉样瘤病(CS)患者进行连续 PET 成像检查是监测治疗反应的常规方法。皮质类固醇仍是治疗 CS 的主要手段。然而,目前还没有关于心血管后果和重复 PET 的最佳时间间隔的数据,同时也没有考虑到皮质类固醇减量对监测成像的影响:我们确定了81例疑似CS患者(年龄:56.3 ± 1.9,67%为男性,LVEF 46.5 ± 3),这些患者均未经治疗且基线PET显示有炎症,随后开始接受中等剂量泼尼松单药治疗(即30-40毫克/天),并进行了诊断性随访PET。治疗反应分为完全反应(CTR)、部分反应(PTR)和无反应(NTR)。根据 PET 扫描之间的随访时间将患者分为三等分;三等分-1(6.8 个月;中位数为 9.8 个月)。通过测量泼尼松从治疗开始到随访一年期间的每周变化情况来了解皮质类固醇的减量情况。主要心血管不良事件(MACE)定义为基线 PET 治疗后第一年内出现的持续性室性心律失常:不同分层的治疗反应 CTR/PTR/NTR 率相似:(1 层(92%) vs 2 层(86.2%) vs 3 层(85.2%);P=0.76)。三组的减量率和一年的泼尼松累积剂量相似(P=0.9)。三等分组之间的短期 MACE 无明显差异(P=0.89)。同样,根据治疗反应状态,MACE也无明显差异(P=0.39):结论:对于仅开始使用中等剂量泼尼松的患者,监视时间和减量率似乎并不影响 PET 扫描的治疗反应。尽管随访时间和治疗反应状态不同,但观察到的 MACE 发生率相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessing the Effect of Repeat PET Imaging on Treatment Response and Cardiovascular Outcomes among a Homogenously Treated Cohort of Patients with Suspected Cardiac Sarcoidosis.

Introduction: Serial PET imaging is routinely employed to monitor treatment response in patients with suspected cardiac sarcoidosis (CS). Corticosteroids remain the mainstay of therapy in CS. However, there are no data available on the cardiovascular outcomes and optimal timing interval to obtain repeat PET while factoring in the influence of corticosteroid taper in relation to surveillance imaging.

Methods: We identified 81 patients with suspected CS (Age: 56.3 ± 1.9, 67% male, LVEF 46.5 ± 3) who were treatment naïve and demonstrated inflammation on baseline PET, subsequently started on moderate-dose prednisone monotherapy (i.e., 30-40 mg/day), and had a diagnostic follow-up PET. Treatment response was graded as complete (CTR) or partial (PTR), and no-response (NTR). Patients were divided into tertiles based on follow-up time between PET scans; tertile-1 (<3.2 months; median 3.1 months), tertile-2 (3.2 - 6.8 months; median 5.9 months), and tertile-3 (>6.8 months; median 9.8 months). Corticosteroid taper was captured by measuring weekly changes in prednisone from start of treatment to up to one-year follow-up. Major adverse cardiovascular events (MACE), defined as sustained ventricular arrhythmias were documented during the first year post-baseline PET.

Results: Treatment response CTR/PTR/NTR rates were similar across tertiles: (tertile-1 (92%) vs tertile-2 (86.2%) vs tertile-3 (85.2%); p=0.76). Taper rates and one-year cumulative prednisone dose were similar between the three groups (P=0.9). No significant difference was found in short-term MACE between the tertile groups (p=0.89). Similarly, MACE did not differ significantly according to treatment response status (p=0.39).

Conclusion: Surveillance time and taper rates do not seem to influence treatment response on PET scans among patients initiated on moderate-dose prednisone only. Similar MACE rates were observed despite variations in follow-up time and treatment response status.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.30
自引率
20.80%
发文量
249
审稿时长
4-8 weeks
期刊介绍: Journal of Nuclear Cardiology is the only journal in the world devoted to this dynamic and growing subspecialty. Physicians and technologists value the Journal not only for its peer-reviewed articles, but also for its timely discussions about the current and future role of nuclear cardiology. Original articles address all aspects of nuclear cardiology, including interpretation, diagnosis, imaging equipment, and use of radiopharmaceuticals. As the official publication of the American Society of Nuclear Cardiology, the Journal also brings readers the latest information emerging from the Society''s task forces and publishes guidelines and position papers as they are adopted.
期刊最新文献
Assessing the Effect of Repeat PET Imaging on Treatment Response and Cardiovascular Outcomes among a Homogenously Treated Cohort of Patients with Suspected Cardiac Sarcoidosis. Correlation between Technetium-99m pyrophosphate myocardial uptake and extracellular volume on cardiac magnetic resonance imaging in patients with transthyretin cardiac amyloidosis. Prognostic value of Transient Ischemic Dilation on Rubidium-82 Positron Emission Tomography Myocardial Perfusion Imaging. Cardiac PET and CMR in Diagnosis of Epi-pericardial Fat Necrosis Associated with Severe Refractory Chest Pain Following Arrhythmia Ablation. New Horizons in Nuclear Cardiology: Imaging of Peripheral Arterial Disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1