Zhang Jiarui , Guo Kailun , Liu Lining , Xue Meng , Wang Chenglong , Tian Wenxi , Qiu Suizheng , Su Guanghui , Chen Chong
{"title":"热失配条件下高温热管的热响应研究","authors":"Zhang Jiarui , Guo Kailun , Liu Lining , Xue Meng , Wang Chenglong , Tian Wenxi , Qiu Suizheng , Su Guanghui , Chen Chong","doi":"10.1016/j.anucene.2024.111075","DOIUrl":null,"url":null,"abstract":"<div><div>As an efficient and reliable passive heat transfer equipment, high temperature heat pipes (HTHPs) plays an important role in HTHP solid state reactor system. HTHPs often encounter thermal mismatch in reactor applications, which will lead to capillary action, entrainment, and other characteristics, resulting in HTHP failure due to heat transfer limits. In this paper, the thermal response test of liquid metal HTHP under thermal mismatch conditions is studied, and the simulation test platform of HTHP mismatch is designed and built to measure the important physical parameters. The test results show that the heat transfer performance of the HTHP is the best under the condition of horizontal inclination of 60°, and the condenser power is 5.66 kW. This condition is selected as the reference condition for the transient condition test. When the HTHP experienced a transient power increase, the middle of the evaporator section, as the part with the largest heat flux of heating power, appeared a severe overheating phenomenon. The wall temperature of the evaporator section soared from 750 ℃ to 1050 ℃ in a short time, and the heating rate reached 18.9 ℃/min, which affected the smooth operation of the HTHP. When the HTHP encounters an inclination angle transient increase condition, the entrainment phenomenon is more severe, the temperature fluctuation of the condenser section is intensified, and the heat transfer of the HTHP is in an unstable state. When the HTHP encounters an inclination angle transient decrease condition, the temperature rise of the evaporator section is less than 10 ℃, the temperature at the end of the condenser section is increased, and the start-up performance of the HTHP is improved. In summary, this paper obtains the thermal response rule of HTHPs under thermal mismatch conditions through experimental research, which provides support for the safe application of HTHPs for special equipment.</div></div>","PeriodicalId":8006,"journal":{"name":"Annals of Nuclear Energy","volume":"212 ","pages":"Article 111075"},"PeriodicalIF":1.9000,"publicationDate":"2024-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation on thermal response of high temperature heat pipe under thermal mismatch conditions\",\"authors\":\"Zhang Jiarui , Guo Kailun , Liu Lining , Xue Meng , Wang Chenglong , Tian Wenxi , Qiu Suizheng , Su Guanghui , Chen Chong\",\"doi\":\"10.1016/j.anucene.2024.111075\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>As an efficient and reliable passive heat transfer equipment, high temperature heat pipes (HTHPs) plays an important role in HTHP solid state reactor system. HTHPs often encounter thermal mismatch in reactor applications, which will lead to capillary action, entrainment, and other characteristics, resulting in HTHP failure due to heat transfer limits. In this paper, the thermal response test of liquid metal HTHP under thermal mismatch conditions is studied, and the simulation test platform of HTHP mismatch is designed and built to measure the important physical parameters. The test results show that the heat transfer performance of the HTHP is the best under the condition of horizontal inclination of 60°, and the condenser power is 5.66 kW. This condition is selected as the reference condition for the transient condition test. When the HTHP experienced a transient power increase, the middle of the evaporator section, as the part with the largest heat flux of heating power, appeared a severe overheating phenomenon. The wall temperature of the evaporator section soared from 750 ℃ to 1050 ℃ in a short time, and the heating rate reached 18.9 ℃/min, which affected the smooth operation of the HTHP. When the HTHP encounters an inclination angle transient increase condition, the entrainment phenomenon is more severe, the temperature fluctuation of the condenser section is intensified, and the heat transfer of the HTHP is in an unstable state. When the HTHP encounters an inclination angle transient decrease condition, the temperature rise of the evaporator section is less than 10 ℃, the temperature at the end of the condenser section is increased, and the start-up performance of the HTHP is improved. In summary, this paper obtains the thermal response rule of HTHPs under thermal mismatch conditions through experimental research, which provides support for the safe application of HTHPs for special equipment.</div></div>\",\"PeriodicalId\":8006,\"journal\":{\"name\":\"Annals of Nuclear Energy\",\"volume\":\"212 \",\"pages\":\"Article 111075\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-11-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Nuclear Energy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0306454924007382\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"NUCLEAR SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Nuclear Energy","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0306454924007382","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
Investigation on thermal response of high temperature heat pipe under thermal mismatch conditions
As an efficient and reliable passive heat transfer equipment, high temperature heat pipes (HTHPs) plays an important role in HTHP solid state reactor system. HTHPs often encounter thermal mismatch in reactor applications, which will lead to capillary action, entrainment, and other characteristics, resulting in HTHP failure due to heat transfer limits. In this paper, the thermal response test of liquid metal HTHP under thermal mismatch conditions is studied, and the simulation test platform of HTHP mismatch is designed and built to measure the important physical parameters. The test results show that the heat transfer performance of the HTHP is the best under the condition of horizontal inclination of 60°, and the condenser power is 5.66 kW. This condition is selected as the reference condition for the transient condition test. When the HTHP experienced a transient power increase, the middle of the evaporator section, as the part with the largest heat flux of heating power, appeared a severe overheating phenomenon. The wall temperature of the evaporator section soared from 750 ℃ to 1050 ℃ in a short time, and the heating rate reached 18.9 ℃/min, which affected the smooth operation of the HTHP. When the HTHP encounters an inclination angle transient increase condition, the entrainment phenomenon is more severe, the temperature fluctuation of the condenser section is intensified, and the heat transfer of the HTHP is in an unstable state. When the HTHP encounters an inclination angle transient decrease condition, the temperature rise of the evaporator section is less than 10 ℃, the temperature at the end of the condenser section is increased, and the start-up performance of the HTHP is improved. In summary, this paper obtains the thermal response rule of HTHPs under thermal mismatch conditions through experimental research, which provides support for the safe application of HTHPs for special equipment.
期刊介绍:
Annals of Nuclear Energy provides an international medium for the communication of original research, ideas and developments in all areas of the field of nuclear energy science and technology. Its scope embraces nuclear fuel reserves, fuel cycles and cost, materials, processing, system and component technology (fission only), design and optimization, direct conversion of nuclear energy sources, environmental control, reactor physics, heat transfer and fluid dynamics, structural analysis, fuel management, future developments, nuclear fuel and safety, nuclear aerosol, neutron physics, computer technology (both software and hardware), risk assessment, radioactive waste disposal and reactor thermal hydraulics. Papers submitted to Annals need to demonstrate a clear link to nuclear power generation/nuclear engineering. Papers which deal with pure nuclear physics, pure health physics, imaging, or attenuation and shielding properties of concretes and various geological materials are not within the scope of the journal. Also, papers that deal with policy or economics are not within the scope of the journal.