{"title":"热失配条件下高温热管的热响应研究","authors":"Zhang Jiarui ,&nbsp;Guo Kailun ,&nbsp;Liu Lining ,&nbsp;Xue Meng ,&nbsp;Wang Chenglong ,&nbsp;Tian Wenxi ,&nbsp;Qiu Suizheng ,&nbsp;Su Guanghui ,&nbsp;Chen Chong","doi":"10.1016/j.anucene.2024.111075","DOIUrl":null,"url":null,"abstract":"<div><div>As an efficient and reliable passive heat transfer equipment, high temperature heat pipes (HTHPs) plays an important role in HTHP solid state reactor system. HTHPs often encounter thermal mismatch in reactor applications, which will lead to capillary action, entrainment, and other characteristics, resulting in HTHP failure due to heat transfer limits. In this paper, the thermal response test of liquid metal HTHP under thermal mismatch conditions is studied, and the simulation test platform of HTHP mismatch is designed and built to measure the important physical parameters. The test results show that the heat transfer performance of the HTHP is the best under the condition of horizontal inclination of 60°, and the condenser power is 5.66 kW. This condition is selected as the reference condition for the transient condition test. When the HTHP experienced a transient power increase, the middle of the evaporator section, as the part with the largest heat flux of heating power, appeared a severe overheating phenomenon. The wall temperature of the evaporator section soared from 750 ℃ to 1050 ℃ in a short time, and the heating rate reached 18.9 ℃/min, which affected the smooth operation of the HTHP. When the HTHP encounters an inclination angle transient increase condition, the entrainment phenomenon is more severe, the temperature fluctuation of the condenser section is intensified, and the heat transfer of the HTHP is in an unstable state. When the HTHP encounters an inclination angle transient decrease condition, the temperature rise of the evaporator section is less than 10 ℃, the temperature at the end of the condenser section is increased, and the start-up performance of the HTHP is improved. In summary, this paper obtains the thermal response rule of HTHPs under thermal mismatch conditions through experimental research, which provides support for the safe application of HTHPs for special equipment.</div></div>","PeriodicalId":8006,"journal":{"name":"Annals of Nuclear Energy","volume":"212 ","pages":"Article 111075"},"PeriodicalIF":1.9000,"publicationDate":"2024-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation on thermal response of high temperature heat pipe under thermal mismatch conditions\",\"authors\":\"Zhang Jiarui ,&nbsp;Guo Kailun ,&nbsp;Liu Lining ,&nbsp;Xue Meng ,&nbsp;Wang Chenglong ,&nbsp;Tian Wenxi ,&nbsp;Qiu Suizheng ,&nbsp;Su Guanghui ,&nbsp;Chen Chong\",\"doi\":\"10.1016/j.anucene.2024.111075\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>As an efficient and reliable passive heat transfer equipment, high temperature heat pipes (HTHPs) plays an important role in HTHP solid state reactor system. HTHPs often encounter thermal mismatch in reactor applications, which will lead to capillary action, entrainment, and other characteristics, resulting in HTHP failure due to heat transfer limits. In this paper, the thermal response test of liquid metal HTHP under thermal mismatch conditions is studied, and the simulation test platform of HTHP mismatch is designed and built to measure the important physical parameters. The test results show that the heat transfer performance of the HTHP is the best under the condition of horizontal inclination of 60°, and the condenser power is 5.66 kW. This condition is selected as the reference condition for the transient condition test. When the HTHP experienced a transient power increase, the middle of the evaporator section, as the part with the largest heat flux of heating power, appeared a severe overheating phenomenon. The wall temperature of the evaporator section soared from 750 ℃ to 1050 ℃ in a short time, and the heating rate reached 18.9 ℃/min, which affected the smooth operation of the HTHP. When the HTHP encounters an inclination angle transient increase condition, the entrainment phenomenon is more severe, the temperature fluctuation of the condenser section is intensified, and the heat transfer of the HTHP is in an unstable state. When the HTHP encounters an inclination angle transient decrease condition, the temperature rise of the evaporator section is less than 10 ℃, the temperature at the end of the condenser section is increased, and the start-up performance of the HTHP is improved. In summary, this paper obtains the thermal response rule of HTHPs under thermal mismatch conditions through experimental research, which provides support for the safe application of HTHPs for special equipment.</div></div>\",\"PeriodicalId\":8006,\"journal\":{\"name\":\"Annals of Nuclear Energy\",\"volume\":\"212 \",\"pages\":\"Article 111075\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-11-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Nuclear Energy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0306454924007382\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"NUCLEAR SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Nuclear Energy","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0306454924007382","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

高温热管(HTHP)作为一种高效可靠的无源传热设备,在高温固态反应器系统中发挥着重要作用。高温热管在反应器应用中经常会遇到热失配,从而导致毛细作用、夹带等特性,导致高温热管因传热受限而失效。本文研究了热失配条件下液态金属 HTHP 的热响应测试,设计并搭建了 HTHP 失配模拟测试平台,测量了重要的物理参数。试验结果表明,在水平倾角为 60° 的条件下,HTHP 的传热性能最好,冷凝器功率为 5.66 kW。瞬态工况试验选择该工况作为参考工况。当 HTHP 出现瞬态功率增加时,蒸发器中部作为加热功率热通量最大的部分,出现了严重的过热现象。蒸发器部分的壁温在短时间内从 750 ℃飙升至 1050 ℃,加热速率达到 18.9 ℃/min,影响了 HTHP 的平稳运行。当 HTHP 遇到倾角瞬时增大工况时,夹带现象更加严重,冷凝器段的温度波动加剧,HTHP 的传热处于不稳定状态。当 HTHP 遇到倾角瞬时减小工况时,蒸发器段温升小于 10 ℃,冷凝器段末端温度升高,HTHP 的启动性能得到改善。综上所述,本文通过实验研究得到了热失配条件下 HTHPs 的热响应规律,为 HTHPs 在特种设备中的安全应用提供了支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Investigation on thermal response of high temperature heat pipe under thermal mismatch conditions
As an efficient and reliable passive heat transfer equipment, high temperature heat pipes (HTHPs) plays an important role in HTHP solid state reactor system. HTHPs often encounter thermal mismatch in reactor applications, which will lead to capillary action, entrainment, and other characteristics, resulting in HTHP failure due to heat transfer limits. In this paper, the thermal response test of liquid metal HTHP under thermal mismatch conditions is studied, and the simulation test platform of HTHP mismatch is designed and built to measure the important physical parameters. The test results show that the heat transfer performance of the HTHP is the best under the condition of horizontal inclination of 60°, and the condenser power is 5.66 kW. This condition is selected as the reference condition for the transient condition test. When the HTHP experienced a transient power increase, the middle of the evaporator section, as the part with the largest heat flux of heating power, appeared a severe overheating phenomenon. The wall temperature of the evaporator section soared from 750 ℃ to 1050 ℃ in a short time, and the heating rate reached 18.9 ℃/min, which affected the smooth operation of the HTHP. When the HTHP encounters an inclination angle transient increase condition, the entrainment phenomenon is more severe, the temperature fluctuation of the condenser section is intensified, and the heat transfer of the HTHP is in an unstable state. When the HTHP encounters an inclination angle transient decrease condition, the temperature rise of the evaporator section is less than 10 ℃, the temperature at the end of the condenser section is increased, and the start-up performance of the HTHP is improved. In summary, this paper obtains the thermal response rule of HTHPs under thermal mismatch conditions through experimental research, which provides support for the safe application of HTHPs for special equipment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Annals of Nuclear Energy
Annals of Nuclear Energy 工程技术-核科学技术
CiteScore
4.30
自引率
21.10%
发文量
632
审稿时长
7.3 months
期刊介绍: Annals of Nuclear Energy provides an international medium for the communication of original research, ideas and developments in all areas of the field of nuclear energy science and technology. Its scope embraces nuclear fuel reserves, fuel cycles and cost, materials, processing, system and component technology (fission only), design and optimization, direct conversion of nuclear energy sources, environmental control, reactor physics, heat transfer and fluid dynamics, structural analysis, fuel management, future developments, nuclear fuel and safety, nuclear aerosol, neutron physics, computer technology (both software and hardware), risk assessment, radioactive waste disposal and reactor thermal hydraulics. Papers submitted to Annals need to demonstrate a clear link to nuclear power generation/nuclear engineering. Papers which deal with pure nuclear physics, pure health physics, imaging, or attenuation and shielding properties of concretes and various geological materials are not within the scope of the journal. Also, papers that deal with policy or economics are not within the scope of the journal.
期刊最新文献
Evaluation of uranium-233 neutron capture cross section in keV region Application of data partitioned Kriging algorithm with GPU acceleration in real-time and refined reconstruction of three-dimensional radiation fields Boiling critical characteristics in narrow rectangular channel under local heat flux concentration conditions Investigation on thermal response of high temperature heat pipe under thermal mismatch conditions Numerical simulation of impurity particles migration and deposition within the 5 × 5 fuel assembly under nucleate boiling conditions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1