Joaquín Osca Asensi , Ignacio Fernández Lozano , Javier Alzueta Rodriguez , David Calvo
{"title":"西班牙植入式心律转复除颤器登记。西班牙心脏病学会心律协会的第 XX 份官方报告(2023 年)。","authors":"Joaquín Osca Asensi , Ignacio Fernández Lozano , Javier Alzueta Rodriguez , David Calvo","doi":"10.1016/j.recesp.2024.08.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>This article presents data on implantable cardioverter-defibrillator implants in Spain in 2023.</div></div><div><h3>Methods</h3><div>The registry is based on information provided by centers following device implantation, which is submitted to the Heart Rhythm Association of the Spanish Society of Cardiology via the national online registry platform (Cardiodispositivos). Additional information sources include: <em>a)</em> data transfer from the manufacturing and marketing industry; and <em>b)</em> local databases sent from the implanting centers. Population data from the National Institute of Statistics for the first quarter of 2024 was used to calculate implant rates.</div></div><div><h3>Results</h3><div>In 2023, 180 hospitals participated in the registry. Data were reported for 8219 units, compared with 8523 reported by Eucomed (European Confederation of Medical Suppliers Associations). The total implant rate was 172 implants per million inhabitants (177 according to Eucomed), representing an increase compared with previous years. However, differences among autonomous communities persisted, and Spain continues to have the lowest implant rate among the European countries participating in Eucomed.</div></div><div><h3>Conclusions</h3><div>The data from the 2023 registry reflects 96.4% of the implants performed in Spain. Despite the improvement observed in the implantation rate, Spain's position in Europe remains unchanged, with wide disparities among autonomous communities.</div></div>","PeriodicalId":21299,"journal":{"name":"Revista espanola de cardiologia","volume":"77 12","pages":"Pages 1037-1049"},"PeriodicalIF":5.9000,"publicationDate":"2024-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Registro español de desfibrilador automático implantable. XX informe oficial de la Asociación del Ritmo Cardiaco de la Sociedad Española de Cardiología (2023)\",\"authors\":\"Joaquín Osca Asensi , Ignacio Fernández Lozano , Javier Alzueta Rodriguez , David Calvo\",\"doi\":\"10.1016/j.recesp.2024.08.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><div>This article presents data on implantable cardioverter-defibrillator implants in Spain in 2023.</div></div><div><h3>Methods</h3><div>The registry is based on information provided by centers following device implantation, which is submitted to the Heart Rhythm Association of the Spanish Society of Cardiology via the national online registry platform (Cardiodispositivos). Additional information sources include: <em>a)</em> data transfer from the manufacturing and marketing industry; and <em>b)</em> local databases sent from the implanting centers. Population data from the National Institute of Statistics for the first quarter of 2024 was used to calculate implant rates.</div></div><div><h3>Results</h3><div>In 2023, 180 hospitals participated in the registry. Data were reported for 8219 units, compared with 8523 reported by Eucomed (European Confederation of Medical Suppliers Associations). The total implant rate was 172 implants per million inhabitants (177 according to Eucomed), representing an increase compared with previous years. However, differences among autonomous communities persisted, and Spain continues to have the lowest implant rate among the European countries participating in Eucomed.</div></div><div><h3>Conclusions</h3><div>The data from the 2023 registry reflects 96.4% of the implants performed in Spain. Despite the improvement observed in the implantation rate, Spain's position in Europe remains unchanged, with wide disparities among autonomous communities.</div></div>\",\"PeriodicalId\":21299,\"journal\":{\"name\":\"Revista espanola de cardiologia\",\"volume\":\"77 12\",\"pages\":\"Pages 1037-1049\"},\"PeriodicalIF\":5.9000,\"publicationDate\":\"2024-08-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista espanola de cardiologia\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0300893224003130\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista espanola de cardiologia","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0300893224003130","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
摘要
导读:本文介绍了 2023 年西班牙植入式心律转复除颤器的数据。方法该登记基于各中心在设备植入后提供的信息,这些信息通过国家在线登记平台(Cardiodispositivos)提交给西班牙心脏病学会心律协会(Heart Rhythm Association of the Society of Cardiology)。其他信息来源包括:a) 来自制造和营销行业的数据传输;b) 来自植入中心的本地数据库。国家统计局提供的 2024 年第一季度人口数据用于计算植入率。共报告了 8219 台设备的数据,而欧洲医疗供应商协会联合会(Eucomed)报告的数据为 8523 台。总植入率为每百万居民 172 例(根据 Eucomed 的数据为 177 例),与前几年相比有所增加。结论 2023 年登记册的数据反映了西班牙 96.4% 的植入手术。尽管植入率有所提高,但西班牙在欧洲的地位仍未改变,各自治区之间的差距很大。
Registro español de desfibrilador automático implantable. XX informe oficial de la Asociación del Ritmo Cardiaco de la Sociedad Española de Cardiología (2023)
Introduction
This article presents data on implantable cardioverter-defibrillator implants in Spain in 2023.
Methods
The registry is based on information provided by centers following device implantation, which is submitted to the Heart Rhythm Association of the Spanish Society of Cardiology via the national online registry platform (Cardiodispositivos). Additional information sources include: a) data transfer from the manufacturing and marketing industry; and b) local databases sent from the implanting centers. Population data from the National Institute of Statistics for the first quarter of 2024 was used to calculate implant rates.
Results
In 2023, 180 hospitals participated in the registry. Data were reported for 8219 units, compared with 8523 reported by Eucomed (European Confederation of Medical Suppliers Associations). The total implant rate was 172 implants per million inhabitants (177 according to Eucomed), representing an increase compared with previous years. However, differences among autonomous communities persisted, and Spain continues to have the lowest implant rate among the European countries participating in Eucomed.
Conclusions
The data from the 2023 registry reflects 96.4% of the implants performed in Spain. Despite the improvement observed in the implantation rate, Spain's position in Europe remains unchanged, with wide disparities among autonomous communities.
期刊介绍:
Revista Española de Cardiología, Revista bilingüe científica internacional, dedicada a las enfermedades cardiovasculares, es la publicación oficial de la Sociedad Española de Cardiología.