继发性二尖瓣反流患者的二尖瓣经导管边缘到边缘修补术(MV-TEER)可改善晚期肾功能不全患者的血流动力学、增强肾功能并优化生活质量。

IF 3.9 3区 工程技术 Q2 BIOCHEMISTRY & MOLECULAR BIOLOGY Biomedicines Pub Date : 2024-11-20 DOI:10.3390/biomedicines12112648
Birgit Markus, Julian Kreutz, Giorgios Chatzis, Styliani Syntila, Jannis Kuchenbuch, Charlotte Mueller, Maryana Choukeir, Bernhard Schieffer, Nikolaos Patsalis
{"title":"继发性二尖瓣反流患者的二尖瓣经导管边缘到边缘修补术(MV-TEER)可改善晚期肾功能不全患者的血流动力学、增强肾功能并优化生活质量。","authors":"Birgit Markus, Julian Kreutz, Giorgios Chatzis, Styliani Syntila, Jannis Kuchenbuch, Charlotte Mueller, Maryana Choukeir, Bernhard Schieffer, Nikolaos Patsalis","doi":"10.3390/biomedicines12112648","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/objectives: </strong>Secondary mitral regurgitation (MR) is a common valvular heart disease burdening the prognosis of patients with co-existing chronic heart failure. Transcatheter edge-to-edge mitral valve repair (MV-TEER) is a minimally invasive treatment option for high-risk patients. However, the effects of MV-TEER on expanded hemodynamics, tissue perfusion, and quality of life, particularly in patients with advanced renal failure, remain underexplored.</p><p><strong>Methods: </strong>This prospective, single-center study evaluated the impact of MV-TEER on hemodynamics, renal function, and quality of life in 45 patients with severe MR. Non-invasive bioimpedance monitoring with NICaS<sup>®</sup> was used to assess hemodynamics pre- and 3-5 days post-procedure. Quality of life was assessed using the EQ-5D-3L questionnaire before and 3 months post-procedure. For further analysis, patients were divided into subgroups based on the estimated baseline glomerular filtration rate (eGFR < 35 mL/min vs. eGFR ≥ 35 mL/min).</p><p><strong>Results: </strong>A significant reduction in systemic vascular resistance (SVR; <i>p</i> = 0.003) and an increase in eGFR (<i>p</i> = 0.03) were observed in the entire cohort after MV-TEER, indicating improved tissue perfusion. Notably, particularly patients with eGFR < 35 mL/min showed a significant increase in cardiac output (CO; <i>p</i> = 0.035), cardiac index (CI; <i>p</i> = 0.031), and eGFR (<i>p</i> = 0.018), as well as a reduction in SVR (<i>p</i> = 0.007). Consistent with these findings, quality of life significantly improved, with the EQ-5D-3L index and EQ-VAS score increasing from 0.44 to 0.66 (<i>p</i> < 0.001) and from 51.7% to 62.9% (<i>p</i> < 0.001).</p>","PeriodicalId":8937,"journal":{"name":"Biomedicines","volume":"12 11","pages":""},"PeriodicalIF":3.9000,"publicationDate":"2024-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11591953/pdf/","citationCount":"0","resultStr":"{\"title\":\"Mitral Valve Transcatheter Edge-to-Edge Repair (MV-TEER) in Patients with Secondary Mitral Regurgitation Improves Hemodynamics, Enhances Renal Function, and Optimizes Quality of Life in Patients with Advanced Renal Insufficiency.\",\"authors\":\"Birgit Markus, Julian Kreutz, Giorgios Chatzis, Styliani Syntila, Jannis Kuchenbuch, Charlotte Mueller, Maryana Choukeir, Bernhard Schieffer, Nikolaos Patsalis\",\"doi\":\"10.3390/biomedicines12112648\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background/objectives: </strong>Secondary mitral regurgitation (MR) is a common valvular heart disease burdening the prognosis of patients with co-existing chronic heart failure. Transcatheter edge-to-edge mitral valve repair (MV-TEER) is a minimally invasive treatment option for high-risk patients. However, the effects of MV-TEER on expanded hemodynamics, tissue perfusion, and quality of life, particularly in patients with advanced renal failure, remain underexplored.</p><p><strong>Methods: </strong>This prospective, single-center study evaluated the impact of MV-TEER on hemodynamics, renal function, and quality of life in 45 patients with severe MR. Non-invasive bioimpedance monitoring with NICaS<sup>®</sup> was used to assess hemodynamics pre- and 3-5 days post-procedure. Quality of life was assessed using the EQ-5D-3L questionnaire before and 3 months post-procedure. For further analysis, patients were divided into subgroups based on the estimated baseline glomerular filtration rate (eGFR < 35 mL/min vs. eGFR ≥ 35 mL/min).</p><p><strong>Results: </strong>A significant reduction in systemic vascular resistance (SVR; <i>p</i> = 0.003) and an increase in eGFR (<i>p</i> = 0.03) were observed in the entire cohort after MV-TEER, indicating improved tissue perfusion. Notably, particularly patients with eGFR < 35 mL/min showed a significant increase in cardiac output (CO; <i>p</i> = 0.035), cardiac index (CI; <i>p</i> = 0.031), and eGFR (<i>p</i> = 0.018), as well as a reduction in SVR (<i>p</i> = 0.007). Consistent with these findings, quality of life significantly improved, with the EQ-5D-3L index and EQ-VAS score increasing from 0.44 to 0.66 (<i>p</i> < 0.001) and from 51.7% to 62.9% (<i>p</i> < 0.001).</p>\",\"PeriodicalId\":8937,\"journal\":{\"name\":\"Biomedicines\",\"volume\":\"12 11\",\"pages\":\"\"},\"PeriodicalIF\":3.9000,\"publicationDate\":\"2024-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11591953/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedicines\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/biomedicines12112648\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedicines","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/biomedicines12112648","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景/目的:继发性二尖瓣反流(MR)是一种常见的瓣膜性心脏病,对合并慢性心力衰竭的患者的预后造成负担。经导管二尖瓣边缘对边缘修补术(MV-TEER)是高风险患者的微创治疗选择。然而,MV-TEER 对扩大血流动力学、组织灌注和生活质量的影响,尤其是对晚期肾衰竭患者的影响,仍未得到充分探讨:这项前瞻性单中心研究评估了 MV-TEER 对 45 名重度 MR 患者的血液动力学、肾功能和生活质量的影响。使用 NICaS® 无创生物阻抗监测评估术前和术后 3-5 天的血液动力学。术前和术后 3 个月的生活质量采用 EQ-5D-3L 问卷进行评估。为了进一步分析,根据估计的基线肾小球滤过率(eGFR < 35 mL/min vs. eGFR ≥ 35 mL/min)将患者分为不同的亚组:结果:MV-TEER 治疗后,整个组群的全身血管阻力(SVR;p = 0.003)明显降低,eGFR(p = 0.03)明显增加,表明组织灌注得到改善。值得注意的是,特别是 eGFR < 35 mL/min 的患者,其心输出量(CO;p = 0.035)、心脏指数(CI;p = 0.031)和 eGFR(p = 0.018)均显著增加,而 SVR 却有所下降(p = 0.007)。与这些研究结果相一致的是,生活质量也得到了显著改善,EQ-5D-3L 指数和 EQ-VAS 评分分别从 0.44 上升至 0.66(p < 0.001)和从 51.7% 上升至 62.9%(p < 0.001)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mitral Valve Transcatheter Edge-to-Edge Repair (MV-TEER) in Patients with Secondary Mitral Regurgitation Improves Hemodynamics, Enhances Renal Function, and Optimizes Quality of Life in Patients with Advanced Renal Insufficiency.

Background/objectives: Secondary mitral regurgitation (MR) is a common valvular heart disease burdening the prognosis of patients with co-existing chronic heart failure. Transcatheter edge-to-edge mitral valve repair (MV-TEER) is a minimally invasive treatment option for high-risk patients. However, the effects of MV-TEER on expanded hemodynamics, tissue perfusion, and quality of life, particularly in patients with advanced renal failure, remain underexplored.

Methods: This prospective, single-center study evaluated the impact of MV-TEER on hemodynamics, renal function, and quality of life in 45 patients with severe MR. Non-invasive bioimpedance monitoring with NICaS® was used to assess hemodynamics pre- and 3-5 days post-procedure. Quality of life was assessed using the EQ-5D-3L questionnaire before and 3 months post-procedure. For further analysis, patients were divided into subgroups based on the estimated baseline glomerular filtration rate (eGFR < 35 mL/min vs. eGFR ≥ 35 mL/min).

Results: A significant reduction in systemic vascular resistance (SVR; p = 0.003) and an increase in eGFR (p = 0.03) were observed in the entire cohort after MV-TEER, indicating improved tissue perfusion. Notably, particularly patients with eGFR < 35 mL/min showed a significant increase in cardiac output (CO; p = 0.035), cardiac index (CI; p = 0.031), and eGFR (p = 0.018), as well as a reduction in SVR (p = 0.007). Consistent with these findings, quality of life significantly improved, with the EQ-5D-3L index and EQ-VAS score increasing from 0.44 to 0.66 (p < 0.001) and from 51.7% to 62.9% (p < 0.001).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biomedicines
Biomedicines Biochemistry, Genetics and Molecular Biology-General Biochemistry,Genetics and Molecular Biology
CiteScore
5.20
自引率
8.50%
发文量
2823
审稿时长
8 weeks
期刊介绍: Biomedicines (ISSN 2227-9059; CODEN: BIOMID) is an international, scientific, open access journal on biomedicines published quarterly online by MDPI.
期刊最新文献
Mitral Valve Transcatheter Edge-to-Edge Repair (MV-TEER) in Patients with Secondary Mitral Regurgitation Improves Hemodynamics, Enhances Renal Function, and Optimizes Quality of Life in Patients with Advanced Renal Insufficiency. Involvement of Lgals3/Galectin-3 in Choroidal Neovascularization and Subretinal Fibrosis Formation. Untangling Depression in Schizophrenia: The Role of Disorganized and Obsessive-Compulsive Symptoms and the Duration of Untreated Psychosis. Update on the Biological and Clinical Relevance of Mast Cells in Chronic Rhinosinusitis with Nasal Polyps. Advancements in Autophagy Modulation for the Management of Oral Disease: A Focus on Drug Targets and Therapeutics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1