左心室辅助装置流出管道方向及其对主动脉血流动力学影响的体外分析。

IF 3.1 3区 医学 Q2 ENGINEERING, BIOMEDICAL ASAIO Journal Pub Date : 2024-12-02 DOI:10.1097/MAT.0000000000002351
Christopher Herz, Maximilian Grab, Christoph Müller, Maja Hanuna, Christine-Elena Kamla, Dirk-André Clevert, Adrian Curta, Nicola Fink, Petra Mela, Christian Hagl, Linda Grefen
{"title":"左心室辅助装置流出管道方向及其对主动脉血流动力学影响的体外分析。","authors":"Christopher Herz, Maximilian Grab, Christoph Müller, Maja Hanuna, Christine-Elena Kamla, Dirk-André Clevert, Adrian Curta, Nicola Fink, Petra Mela, Christian Hagl, Linda Grefen","doi":"10.1097/MAT.0000000000002351","DOIUrl":null,"url":null,"abstract":"<p><p>Continuous-flow left ventricular assist devices have become an important treatment option for patients with advanced heart failure. However, adverse hemodynamic effects as consequence of an altered blood flow within the aorta and the aortic root remain a topic of concern. In this work, we investigated the influence of the outflow graft orientation on the hemodynamic profile and flow parameters within the thoracic aorta. Aortic models with different outflow graft orientations were designed and three-dimensional (3D) printed to mimic common implantation configurations and were integrated into a pulsatile mock circulatory flow loop. Assist device function was achieved using a rotary pump, replicating nonpulsatile, continuous support flows of 1-5 L/min. Flow velocity, wall shear stress, and pressure gradients were investigated for each configuration using sonography and four-dimensional (4D) flow magnetic resonance imaging. Mean wall shear stresses measured in 4D flow software were lowest for a graft inclination angle of 45°. Streamline visualization revealed areas of nonuniform, retrograde, and vortex flow in all models but most prominent for the aortic model with an outflow graft inclination of 60°. The insights gained from this research may aid in understanding clinical outcomes following assist device implantation and long-term mechanical circulatory support.</p>","PeriodicalId":8844,"journal":{"name":"ASAIO Journal","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In Vitro Analysis of Left Ventricular Assist Device Outflow Graft Orientations and Their Effect on Aortic Hemodynamics.\",\"authors\":\"Christopher Herz, Maximilian Grab, Christoph Müller, Maja Hanuna, Christine-Elena Kamla, Dirk-André Clevert, Adrian Curta, Nicola Fink, Petra Mela, Christian Hagl, Linda Grefen\",\"doi\":\"10.1097/MAT.0000000000002351\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Continuous-flow left ventricular assist devices have become an important treatment option for patients with advanced heart failure. However, adverse hemodynamic effects as consequence of an altered blood flow within the aorta and the aortic root remain a topic of concern. In this work, we investigated the influence of the outflow graft orientation on the hemodynamic profile and flow parameters within the thoracic aorta. Aortic models with different outflow graft orientations were designed and three-dimensional (3D) printed to mimic common implantation configurations and were integrated into a pulsatile mock circulatory flow loop. Assist device function was achieved using a rotary pump, replicating nonpulsatile, continuous support flows of 1-5 L/min. Flow velocity, wall shear stress, and pressure gradients were investigated for each configuration using sonography and four-dimensional (4D) flow magnetic resonance imaging. Mean wall shear stresses measured in 4D flow software were lowest for a graft inclination angle of 45°. Streamline visualization revealed areas of nonuniform, retrograde, and vortex flow in all models but most prominent for the aortic model with an outflow graft inclination of 60°. The insights gained from this research may aid in understanding clinical outcomes following assist device implantation and long-term mechanical circulatory support.</p>\",\"PeriodicalId\":8844,\"journal\":{\"name\":\"ASAIO Journal\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-12-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ASAIO Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1097/MAT.0000000000002351\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1097/MAT.0000000000002351","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

持续流左心室辅助装置已成为晚期心力衰竭患者的重要治疗选择。然而,主动脉和主动脉根部血流改变对血流动力学的不利影响仍然是一个令人担忧的问题。在这项工作中,我们研究了流出移植方向对胸主动脉血流动力学特征和血流参数的影响。我们设计并三维(3D)打印了具有不同流出移植方向的主动脉模型,以模拟常见的植入配置,并将其整合到脉动模拟循环流环路中。辅助装置的功能是通过旋转泵实现的,复制了 1-5 升/分钟的非搏动性持续支持流量。使用声波成像和四维(4D)血流磁共振成像对每种配置的流速、壁切应力和压力梯度进行了研究。四维流体软件测得的平均壁剪应力在移植物倾斜角为 45°时最低。流线可视化显示了所有模型中不均匀、逆流和涡流的区域,但在流出移植物倾斜 60° 的主动脉模型中最为突出。这项研究获得的启示有助于了解辅助装置植入和长期机械循环支持后的临床结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In Vitro Analysis of Left Ventricular Assist Device Outflow Graft Orientations and Their Effect on Aortic Hemodynamics.

Continuous-flow left ventricular assist devices have become an important treatment option for patients with advanced heart failure. However, adverse hemodynamic effects as consequence of an altered blood flow within the aorta and the aortic root remain a topic of concern. In this work, we investigated the influence of the outflow graft orientation on the hemodynamic profile and flow parameters within the thoracic aorta. Aortic models with different outflow graft orientations were designed and three-dimensional (3D) printed to mimic common implantation configurations and were integrated into a pulsatile mock circulatory flow loop. Assist device function was achieved using a rotary pump, replicating nonpulsatile, continuous support flows of 1-5 L/min. Flow velocity, wall shear stress, and pressure gradients were investigated for each configuration using sonography and four-dimensional (4D) flow magnetic resonance imaging. Mean wall shear stresses measured in 4D flow software were lowest for a graft inclination angle of 45°. Streamline visualization revealed areas of nonuniform, retrograde, and vortex flow in all models but most prominent for the aortic model with an outflow graft inclination of 60°. The insights gained from this research may aid in understanding clinical outcomes following assist device implantation and long-term mechanical circulatory support.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ASAIO Journal
ASAIO Journal 医学-工程:生物医学
CiteScore
6.60
自引率
7.10%
发文量
651
审稿时长
4-8 weeks
期刊介绍: ASAIO Journal is in the forefront of artificial organ research and development. On the cutting edge of innovative technology, it features peer-reviewed articles of the highest quality that describe research, development, the most recent advances in the design of artificial organ devices and findings from initial testing. Bimonthly, the ASAIO Journal features state-of-the-art investigations, laboratory and clinical trials, and discussions and opinions from experts around the world. The official publication of the American Society for Artificial Internal Organs.
期刊最新文献
In Vitro Analysis of Left Ventricular Assist Device Outflow Graft Orientations and Their Effect on Aortic Hemodynamics. Prosthetic Valve Fate in Patients With Continuous-Flow Left Ventricular Assist Devices. Heart Transplantation Outcomes in Patients With Hypertrophic Cardiomyopathy in the Era of Mechanical Circulatory Support. Predictive Accuracy of HeartMate 3 Risk Score After the Heart Transplant Allocation Change. Reply Letter to Editor to Daniel Schneditz.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1