Christopher Herz, Maximilian Grab, Christoph Müller, Maja Hanuna, Christine-Elena Kamla, Dirk-André Clevert, Adrian Curta, Nicola Fink, Petra Mela, Christian Hagl, Linda Grefen
{"title":"左心室辅助装置流出管道方向及其对主动脉血流动力学影响的体外分析。","authors":"Christopher Herz, Maximilian Grab, Christoph Müller, Maja Hanuna, Christine-Elena Kamla, Dirk-André Clevert, Adrian Curta, Nicola Fink, Petra Mela, Christian Hagl, Linda Grefen","doi":"10.1097/MAT.0000000000002351","DOIUrl":null,"url":null,"abstract":"<p><p>Continuous-flow left ventricular assist devices have become an important treatment option for patients with advanced heart failure. However, adverse hemodynamic effects as consequence of an altered blood flow within the aorta and the aortic root remain a topic of concern. In this work, we investigated the influence of the outflow graft orientation on the hemodynamic profile and flow parameters within the thoracic aorta. Aortic models with different outflow graft orientations were designed and three-dimensional (3D) printed to mimic common implantation configurations and were integrated into a pulsatile mock circulatory flow loop. Assist device function was achieved using a rotary pump, replicating nonpulsatile, continuous support flows of 1-5 L/min. Flow velocity, wall shear stress, and pressure gradients were investigated for each configuration using sonography and four-dimensional (4D) flow magnetic resonance imaging. Mean wall shear stresses measured in 4D flow software were lowest for a graft inclination angle of 45°. Streamline visualization revealed areas of nonuniform, retrograde, and vortex flow in all models but most prominent for the aortic model with an outflow graft inclination of 60°. The insights gained from this research may aid in understanding clinical outcomes following assist device implantation and long-term mechanical circulatory support.</p>","PeriodicalId":8844,"journal":{"name":"ASAIO Journal","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In Vitro Analysis of Left Ventricular Assist Device Outflow Graft Orientations and Their Effect on Aortic Hemodynamics.\",\"authors\":\"Christopher Herz, Maximilian Grab, Christoph Müller, Maja Hanuna, Christine-Elena Kamla, Dirk-André Clevert, Adrian Curta, Nicola Fink, Petra Mela, Christian Hagl, Linda Grefen\",\"doi\":\"10.1097/MAT.0000000000002351\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Continuous-flow left ventricular assist devices have become an important treatment option for patients with advanced heart failure. However, adverse hemodynamic effects as consequence of an altered blood flow within the aorta and the aortic root remain a topic of concern. In this work, we investigated the influence of the outflow graft orientation on the hemodynamic profile and flow parameters within the thoracic aorta. Aortic models with different outflow graft orientations were designed and three-dimensional (3D) printed to mimic common implantation configurations and were integrated into a pulsatile mock circulatory flow loop. Assist device function was achieved using a rotary pump, replicating nonpulsatile, continuous support flows of 1-5 L/min. Flow velocity, wall shear stress, and pressure gradients were investigated for each configuration using sonography and four-dimensional (4D) flow magnetic resonance imaging. Mean wall shear stresses measured in 4D flow software were lowest for a graft inclination angle of 45°. Streamline visualization revealed areas of nonuniform, retrograde, and vortex flow in all models but most prominent for the aortic model with an outflow graft inclination of 60°. The insights gained from this research may aid in understanding clinical outcomes following assist device implantation and long-term mechanical circulatory support.</p>\",\"PeriodicalId\":8844,\"journal\":{\"name\":\"ASAIO Journal\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-12-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ASAIO Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1097/MAT.0000000000002351\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1097/MAT.0000000000002351","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
In Vitro Analysis of Left Ventricular Assist Device Outflow Graft Orientations and Their Effect on Aortic Hemodynamics.
Continuous-flow left ventricular assist devices have become an important treatment option for patients with advanced heart failure. However, adverse hemodynamic effects as consequence of an altered blood flow within the aorta and the aortic root remain a topic of concern. In this work, we investigated the influence of the outflow graft orientation on the hemodynamic profile and flow parameters within the thoracic aorta. Aortic models with different outflow graft orientations were designed and three-dimensional (3D) printed to mimic common implantation configurations and were integrated into a pulsatile mock circulatory flow loop. Assist device function was achieved using a rotary pump, replicating nonpulsatile, continuous support flows of 1-5 L/min. Flow velocity, wall shear stress, and pressure gradients were investigated for each configuration using sonography and four-dimensional (4D) flow magnetic resonance imaging. Mean wall shear stresses measured in 4D flow software were lowest for a graft inclination angle of 45°. Streamline visualization revealed areas of nonuniform, retrograde, and vortex flow in all models but most prominent for the aortic model with an outflow graft inclination of 60°. The insights gained from this research may aid in understanding clinical outcomes following assist device implantation and long-term mechanical circulatory support.
期刊介绍:
ASAIO Journal is in the forefront of artificial organ research and development. On the cutting edge of innovative technology, it features peer-reviewed articles of the highest quality that describe research, development, the most recent advances in the design of artificial organ devices and findings from initial testing. Bimonthly, the ASAIO Journal features state-of-the-art investigations, laboratory and clinical trials, and discussions and opinions from experts around the world.
The official publication of the American Society for Artificial Internal Organs.