Lisa Alibrandi, Tommaso Vezzosi, Eliana Bozzolo, Giovanni Grosso, Oriol Domenech, Rosalba Tognetti
{"title":"数字听诊器与猫咪同步心音和心电图的临床评估。","authors":"Lisa Alibrandi, Tommaso Vezzosi, Eliana Bozzolo, Giovanni Grosso, Oriol Domenech, Rosalba Tognetti","doi":"10.1007/s11259-024-10600-z","DOIUrl":null,"url":null,"abstract":"<p><p>A smartphone-based technology combining a digital stethoscope (DS) with simultaneous phonocardiography (PCG) and 1-lead electrocardiogram (ECG) is available. The aim of the present study was to evaluate the sensitivity and specificity of the DS for the detection of heart disease in cats considering transthoracic echocardiography as gold standard. The study is prospective and observational inlcuding 42 client-owned cats. All cases underwent auscultation with a conventional stethoscope (CS), recording with the DS, 6-lead ECG and echocardiography. All the recordings were blindly reviewed. The agreement with standard methods was assessed using the Cohen's kappa and the Bland-Altman test. The Fisher's exact test was used to test the effect of shaving on tracings' quality. Intraoperator and interoperator variability were assessed with Cohen's k and Fleiss' k, respectively. Audio recordings obtained with DS were interpretable in 100% of the cats. The agreement between DS and echocardiography in detecting heart disease was substantial (k = 0.714), while between CS and echocardiography the agreement was moderate (k = 0.571). Intraoperator and interoperator agreement was almost perfect (k = 0.904; k = 0.867, respectively). The ECG tracings recorded with the DS were interpretable in 83% of the cats and the device was reliable in assessing basic ECG measurements. No significant differences were found in the quality of the audio and ECG tracings in relation to the shaving condition. Based on the efficacy of detecting cardiac murmurs and gallop sound, the DS can be considered a reliable tool for cardiac auscultation in cats, producing good quality audio and ECG tracings also suitable for possible remote interpretation.</p>","PeriodicalId":23690,"journal":{"name":"Veterinary Research Communications","volume":"49 1","pages":"44"},"PeriodicalIF":1.8000,"publicationDate":"2024-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical evaluation of a digital stethoscope with simultaneous phonocardiography and electrocardiography in cats.\",\"authors\":\"Lisa Alibrandi, Tommaso Vezzosi, Eliana Bozzolo, Giovanni Grosso, Oriol Domenech, Rosalba Tognetti\",\"doi\":\"10.1007/s11259-024-10600-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A smartphone-based technology combining a digital stethoscope (DS) with simultaneous phonocardiography (PCG) and 1-lead electrocardiogram (ECG) is available. The aim of the present study was to evaluate the sensitivity and specificity of the DS for the detection of heart disease in cats considering transthoracic echocardiography as gold standard. The study is prospective and observational inlcuding 42 client-owned cats. All cases underwent auscultation with a conventional stethoscope (CS), recording with the DS, 6-lead ECG and echocardiography. All the recordings were blindly reviewed. The agreement with standard methods was assessed using the Cohen's kappa and the Bland-Altman test. The Fisher's exact test was used to test the effect of shaving on tracings' quality. Intraoperator and interoperator variability were assessed with Cohen's k and Fleiss' k, respectively. Audio recordings obtained with DS were interpretable in 100% of the cats. The agreement between DS and echocardiography in detecting heart disease was substantial (k = 0.714), while between CS and echocardiography the agreement was moderate (k = 0.571). Intraoperator and interoperator agreement was almost perfect (k = 0.904; k = 0.867, respectively). The ECG tracings recorded with the DS were interpretable in 83% of the cats and the device was reliable in assessing basic ECG measurements. No significant differences were found in the quality of the audio and ECG tracings in relation to the shaving condition. Based on the efficacy of detecting cardiac murmurs and gallop sound, the DS can be considered a reliable tool for cardiac auscultation in cats, producing good quality audio and ECG tracings also suitable for possible remote interpretation.</p>\",\"PeriodicalId\":23690,\"journal\":{\"name\":\"Veterinary Research Communications\",\"volume\":\"49 1\",\"pages\":\"44\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-11-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary Research Communications\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1007/s11259-024-10600-z\",\"RegionNum\":3,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Research Communications","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1007/s11259-024-10600-z","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
Clinical evaluation of a digital stethoscope with simultaneous phonocardiography and electrocardiography in cats.
A smartphone-based technology combining a digital stethoscope (DS) with simultaneous phonocardiography (PCG) and 1-lead electrocardiogram (ECG) is available. The aim of the present study was to evaluate the sensitivity and specificity of the DS for the detection of heart disease in cats considering transthoracic echocardiography as gold standard. The study is prospective and observational inlcuding 42 client-owned cats. All cases underwent auscultation with a conventional stethoscope (CS), recording with the DS, 6-lead ECG and echocardiography. All the recordings were blindly reviewed. The agreement with standard methods was assessed using the Cohen's kappa and the Bland-Altman test. The Fisher's exact test was used to test the effect of shaving on tracings' quality. Intraoperator and interoperator variability were assessed with Cohen's k and Fleiss' k, respectively. Audio recordings obtained with DS were interpretable in 100% of the cats. The agreement between DS and echocardiography in detecting heart disease was substantial (k = 0.714), while between CS and echocardiography the agreement was moderate (k = 0.571). Intraoperator and interoperator agreement was almost perfect (k = 0.904; k = 0.867, respectively). The ECG tracings recorded with the DS were interpretable in 83% of the cats and the device was reliable in assessing basic ECG measurements. No significant differences were found in the quality of the audio and ECG tracings in relation to the shaving condition. Based on the efficacy of detecting cardiac murmurs and gallop sound, the DS can be considered a reliable tool for cardiac auscultation in cats, producing good quality audio and ECG tracings also suitable for possible remote interpretation.
期刊介绍:
Veterinary Research Communications publishes fully refereed research articles and topical reviews on all aspects of the veterinary sciences. Interdisciplinary articles are particularly encouraged, as are well argued reviews, even if they are somewhat controversial.
The journal is an appropriate medium in which to publish new methods, newly described diseases and new pathological findings, as these are applied to animals. The material should be of international rather than local interest. As it deliberately seeks a wide coverage, Veterinary Research Communications provides its readers with a means of keeping abreast of current developments in the entire field of veterinary science.