{"title":"日本患者使用 Amplatzer 血管堵塞器和管道闭塞器经导管封堵二尖瓣口腔旁漏后的早期疗效。","authors":"Hiroki Niikura, Kenji Makino, Norihiro Kogame, Go Hashimoto, Yoshiyuki Yazaki, Hidehiko Hara","doi":"10.1253/circj.CJ-24-0544","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Transcatheter closure of paravalvular leak (PVL) has become an established treatment for patients at prohibitive surgical risk. However, few studies have examined the feasibility of transcatheter closure using Amplatzer occluders in Japanese patients with mitral PVL.</p><p><strong>Methods and results: </strong>Twelve patients (mean [±SD] age 78±7 years) with heart failure, hemolytic anemia, or both after surgical mitral prosthetic valve replacement (mechanical valve, 75%) underwent transcatheter PVL closure with Amplatzer Vascular Plug II (AVP-II)/Amplatzer Duct Occluder II (ADO-II) between 2014 and 2021 at Toho University Ohashi Medical Center. We examined procedural, in-hospital, 30-day, and 1-year outcomes. All procedures were performed under general anesthesia using an antegrade transseptal approach, and the procedures were successful in all cases. The mean (±SD) number of Amplatzer occluders deployment per patient was 2.9±1.1, and in 2 patients the combined use of ADO-II was required. The mitral PVL grade decreased notably from 3+ to 1+, with residual PVL being mild or absent in 9 patients. There were no all-cause mortalities, major adverse events, or device-related complications at the 30-day follow-up. At 1 year, all-cause mortality was 16.7% and 3 (25%) patients required reintervention because of the recurrence of clinical symptoms.</p><p><strong>Conclusions: </strong>Our findings suggest that transcatheter PVL closure with AVP-II/ADO-II can be feasible and safe in Japanese patients with mitral PVL, leading to satisfactory early clinical outcomes.</p>","PeriodicalId":50691,"journal":{"name":"Circulation Journal","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Early Outcomes Following Transcatheter Closure With the Amplatzer Vascular Plug and Duct Occluder for Mitral Paravalvular Leak in Japanese Patients.\",\"authors\":\"Hiroki Niikura, Kenji Makino, Norihiro Kogame, Go Hashimoto, Yoshiyuki Yazaki, Hidehiko Hara\",\"doi\":\"10.1253/circj.CJ-24-0544\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Transcatheter closure of paravalvular leak (PVL) has become an established treatment for patients at prohibitive surgical risk. However, few studies have examined the feasibility of transcatheter closure using Amplatzer occluders in Japanese patients with mitral PVL.</p><p><strong>Methods and results: </strong>Twelve patients (mean [±SD] age 78±7 years) with heart failure, hemolytic anemia, or both after surgical mitral prosthetic valve replacement (mechanical valve, 75%) underwent transcatheter PVL closure with Amplatzer Vascular Plug II (AVP-II)/Amplatzer Duct Occluder II (ADO-II) between 2014 and 2021 at Toho University Ohashi Medical Center. We examined procedural, in-hospital, 30-day, and 1-year outcomes. All procedures were performed under general anesthesia using an antegrade transseptal approach, and the procedures were successful in all cases. The mean (±SD) number of Amplatzer occluders deployment per patient was 2.9±1.1, and in 2 patients the combined use of ADO-II was required. The mitral PVL grade decreased notably from 3+ to 1+, with residual PVL being mild or absent in 9 patients. There were no all-cause mortalities, major adverse events, or device-related complications at the 30-day follow-up. At 1 year, all-cause mortality was 16.7% and 3 (25%) patients required reintervention because of the recurrence of clinical symptoms.</p><p><strong>Conclusions: </strong>Our findings suggest that transcatheter PVL closure with AVP-II/ADO-II can be feasible and safe in Japanese patients with mitral PVL, leading to satisfactory early clinical outcomes.</p>\",\"PeriodicalId\":50691,\"journal\":{\"name\":\"Circulation Journal\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-11-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Circulation Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1253/circj.CJ-24-0544\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1253/circj.CJ-24-0544","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:经导管闭合瓣下漏(PVL)已成为一种治疗手术风险过高患者的成熟方法。然而,很少有研究对日本二尖瓣口漏患者使用 Amplatzer 闭塞器进行经导管封堵的可行性进行研究:2014年至2021年期间,东邦大学大桥医疗中心为12名心力衰竭、溶血性贫血或两者兼有的二尖瓣人工瓣膜置换术(机械瓣,75%)患者(平均[±SD]年龄为78±7岁)使用Amplatzer血管塞II(AVP-II)/Amplatzer导管封堵器II(ADO-II)进行了经导管PVL封堵术。我们研究了手术、院内、30 天和 1 年的结果。所有手术都是在全身麻醉下使用前向经皮途径进行的,所有病例的手术都很成功。每位患者使用的 Amplatzer 封堵器的平均数量(±SD)为 2.9±1.1,有 2 位患者需要联合使用 ADO-II。二尖瓣 PVL 分级从 3+ 显著降至 1+,9 名患者的残余 PVL 为轻度或不存在。在 30 天的随访中,没有出现全因死亡、重大不良事件或与设备相关的并发症。1年后,全因死亡率为16.7%,3名(25%)患者因临床症状复发而需要再次介入治疗:我们的研究结果表明,使用 AVP-II/ADO-II 经导管关闭二尖瓣下腔静脉(PVL)对日本二尖瓣下腔静脉(PVL)患者是可行且安全的,并能带来令人满意的早期临床效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Early Outcomes Following Transcatheter Closure With the Amplatzer Vascular Plug and Duct Occluder for Mitral Paravalvular Leak in Japanese Patients.

Background: Transcatheter closure of paravalvular leak (PVL) has become an established treatment for patients at prohibitive surgical risk. However, few studies have examined the feasibility of transcatheter closure using Amplatzer occluders in Japanese patients with mitral PVL.

Methods and results: Twelve patients (mean [±SD] age 78±7 years) with heart failure, hemolytic anemia, or both after surgical mitral prosthetic valve replacement (mechanical valve, 75%) underwent transcatheter PVL closure with Amplatzer Vascular Plug II (AVP-II)/Amplatzer Duct Occluder II (ADO-II) between 2014 and 2021 at Toho University Ohashi Medical Center. We examined procedural, in-hospital, 30-day, and 1-year outcomes. All procedures were performed under general anesthesia using an antegrade transseptal approach, and the procedures were successful in all cases. The mean (±SD) number of Amplatzer occluders deployment per patient was 2.9±1.1, and in 2 patients the combined use of ADO-II was required. The mitral PVL grade decreased notably from 3+ to 1+, with residual PVL being mild or absent in 9 patients. There were no all-cause mortalities, major adverse events, or device-related complications at the 30-day follow-up. At 1 year, all-cause mortality was 16.7% and 3 (25%) patients required reintervention because of the recurrence of clinical symptoms.

Conclusions: Our findings suggest that transcatheter PVL closure with AVP-II/ADO-II can be feasible and safe in Japanese patients with mitral PVL, leading to satisfactory early clinical outcomes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Circulation Journal
Circulation Journal 医学-心血管系统
CiteScore
5.80
自引率
12.10%
发文量
471
审稿时长
1.6 months
期刊介绍: Circulation publishes original research manuscripts, review articles, and other content related to cardiovascular health and disease, including observational studies, clinical trials, epidemiology, health services and outcomes studies, and advances in basic and translational research.
期刊最新文献
Early Outcomes Following Transcatheter Closure With the Amplatzer Vascular Plug and Duct Occluder for Mitral Paravalvular Leak in Japanese Patients. Prognostic Value of Endogenous-Type Coronary Microvascular Dysfunction After Elective Percutaneous Coronary Intervention. Maternal Death Due to Pulmonary Arterial Hypertension - A Nationwide Survey in Japan. Concomitant Mitral Regurgitation in Severe Aortic Stenosis - Insights From the CURRENT AS Registry-2. Five-Year Transcatheter Aortic Valve Replacement Outcomes in Chronic Hemodialysis vs. Non-Hemodialysis Patients Using Balloon-Expandable Devices.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1