Samu Pettersson, Petra C. Lindholm-Lehto, Jani T. Pulkkinen, Tuula Tuhkanen
{"title":"高级氧化法和双氧水处理在循环水养殖系统中的去除异味研究","authors":"Samu Pettersson, Petra C. Lindholm-Lehto, Jani T. Pulkkinen, Tuula Tuhkanen","doi":"10.1002/aff2.70023","DOIUrl":null,"url":null,"abstract":"<p>Aquaculture is becoming increasingly important for the world's food production. Recirculating aquaculture system (RAS) has a reduced water requirement and better possibilities for waste handling. Unfortunately, off-flavours can be formed in RAS and concentrate on fish flesh. Off-flavour compounds cause earthy, musty or other unwanted flavours to fish flesh that consumers find objectionable. Typically, off-flavours are removed by depurating the fish in clean water, but it often takes from days to weeks to fully remove these unwanted flavours that causes additional costs to fish producers. Therefore, reliable methods to reduce the need for depuration are needed. In this study, two methods were investigated for the removal of off-flavours in RAS rearing rainbow trout <i>Oncorhynchus mykiss</i>: an advanced oxidation process (AOP) using a combination of ozone (O<sub>3</sub>) and hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>), and a treatment with H<sub>2</sub>O<sub>2</sub> alone. Two treatments (AOP and H<sub>2</sub>O<sub>2</sub>) and a control without oxidants were applied across nine identical experimental RASs for 8 h day<sup>−1</sup> over 10 days, and selected off-flavour compounds in water and fish were analysed. In fish, the concentrations of GSM and MIB were on average 776 and 962 ng kg<sup>−1</sup> (AOP) and 688 and 919 ng kg<sup>−1</sup> (H<sub>2</sub>O<sub>2</sub>) compared to 1071 and 1205 ng kg<sup>−1</sup> in the controls. The results showed that intensive oxidant treatments reduced the off-flavour concentrations in the recirculating water and in fish, which can potentially lead to reduced depuration time and production costs. Further optimization of the treatment is needed to improve off-flavour removal efficiencies.</p>","PeriodicalId":100114,"journal":{"name":"Aquaculture, Fish and Fisheries","volume":"4 6","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/aff2.70023","citationCount":"0","resultStr":"{\"title\":\"Off-Flavour Removal With Advanced Oxidation Process and Hydrogen Peroxide Treatments in Recirculating Aquaculture Systems\",\"authors\":\"Samu Pettersson, Petra C. Lindholm-Lehto, Jani T. Pulkkinen, Tuula Tuhkanen\",\"doi\":\"10.1002/aff2.70023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Aquaculture is becoming increasingly important for the world's food production. Recirculating aquaculture system (RAS) has a reduced water requirement and better possibilities for waste handling. Unfortunately, off-flavours can be formed in RAS and concentrate on fish flesh. Off-flavour compounds cause earthy, musty or other unwanted flavours to fish flesh that consumers find objectionable. Typically, off-flavours are removed by depurating the fish in clean water, but it often takes from days to weeks to fully remove these unwanted flavours that causes additional costs to fish producers. Therefore, reliable methods to reduce the need for depuration are needed. In this study, two methods were investigated for the removal of off-flavours in RAS rearing rainbow trout <i>Oncorhynchus mykiss</i>: an advanced oxidation process (AOP) using a combination of ozone (O<sub>3</sub>) and hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>), and a treatment with H<sub>2</sub>O<sub>2</sub> alone. Two treatments (AOP and H<sub>2</sub>O<sub>2</sub>) and a control without oxidants were applied across nine identical experimental RASs for 8 h day<sup>−1</sup> over 10 days, and selected off-flavour compounds in water and fish were analysed. In fish, the concentrations of GSM and MIB were on average 776 and 962 ng kg<sup>−1</sup> (AOP) and 688 and 919 ng kg<sup>−1</sup> (H<sub>2</sub>O<sub>2</sub>) compared to 1071 and 1205 ng kg<sup>−1</sup> in the controls. The results showed that intensive oxidant treatments reduced the off-flavour concentrations in the recirculating water and in fish, which can potentially lead to reduced depuration time and production costs. Further optimization of the treatment is needed to improve off-flavour removal efficiencies.</p>\",\"PeriodicalId\":100114,\"journal\":{\"name\":\"Aquaculture, Fish and Fisheries\",\"volume\":\"4 6\",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/aff2.70023\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Aquaculture, Fish and Fisheries\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/aff2.70023\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"FISHERIES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aquaculture, Fish and Fisheries","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/aff2.70023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"FISHERIES","Score":null,"Total":0}
引用次数: 0
摘要
水产养殖对世界粮食生产越来越重要。循环水养殖系统(RAS)需水量减少,废物处理的可能性更大。不幸的是,RAS会形成异味,并集中在鱼肉上。异味化合物会给鱼肉带来泥土味、霉味或其他消费者不喜欢的味道。通常,通过在清水中净化鱼来去除异味,但通常需要几天到几周的时间才能完全去除这些不需要的味道,这给鱼类生产商带来了额外的成本。因此,需要可靠的方法来减少净化的需要。本研究研究了两种去除RAS养殖虹鳟鱼异味的方法:臭氧(O3)和过氧化氢(H2O2)联合高级氧化法(AOP)和单独H2O2处理法。两种处理(AOP和H2O2)和不含氧化剂的对照在9个相同的实验RASs上施用8 h day - 1,超过10天,并分析了水和鱼中选定的非风味化合物。在鱼类中,GSM和MIB的平均浓度分别为776和962 ng kg - 1 (AOP)和688和919 ng kg - 1 (H2O2),而对照组为1071和1205 ng kg - 1。结果表明,强化氧化处理降低了循环水和鱼体内的异味浓度,这可能会减少净化时间和生产成本。需要进一步优化处理以提高脱除异味的效率。
Off-Flavour Removal With Advanced Oxidation Process and Hydrogen Peroxide Treatments in Recirculating Aquaculture Systems
Aquaculture is becoming increasingly important for the world's food production. Recirculating aquaculture system (RAS) has a reduced water requirement and better possibilities for waste handling. Unfortunately, off-flavours can be formed in RAS and concentrate on fish flesh. Off-flavour compounds cause earthy, musty or other unwanted flavours to fish flesh that consumers find objectionable. Typically, off-flavours are removed by depurating the fish in clean water, but it often takes from days to weeks to fully remove these unwanted flavours that causes additional costs to fish producers. Therefore, reliable methods to reduce the need for depuration are needed. In this study, two methods were investigated for the removal of off-flavours in RAS rearing rainbow trout Oncorhynchus mykiss: an advanced oxidation process (AOP) using a combination of ozone (O3) and hydrogen peroxide (H2O2), and a treatment with H2O2 alone. Two treatments (AOP and H2O2) and a control without oxidants were applied across nine identical experimental RASs for 8 h day−1 over 10 days, and selected off-flavour compounds in water and fish were analysed. In fish, the concentrations of GSM and MIB were on average 776 and 962 ng kg−1 (AOP) and 688 and 919 ng kg−1 (H2O2) compared to 1071 and 1205 ng kg−1 in the controls. The results showed that intensive oxidant treatments reduced the off-flavour concentrations in the recirculating water and in fish, which can potentially lead to reduced depuration time and production costs. Further optimization of the treatment is needed to improve off-flavour removal efficiencies.