主动脉脉搏波速度的搏动变异性:对主动脉硬度测量的影响。

IF 3.3 2区 医学 Q1 PERIPHERAL VASCULAR DISEASE Journal of Hypertension Pub Date : 2025-04-01 Epub Date: 2025-02-07 DOI:10.1097/HJH.0000000000003935
Alessandro Giudici, Andrea Grillo, Filippo Scalise, Koen D Reesink, Tammo Delhaas, Paolo Salvi, Bart Spronck, Gianfranco Parati
{"title":"主动脉脉搏波速度的搏动变异性:对主动脉硬度测量的影响。","authors":"Alessandro Giudici, Andrea Grillo, Filippo Scalise, Koen D Reesink, Tammo Delhaas, Paolo Salvi, Bart Spronck, Gianfranco Parati","doi":"10.1097/HJH.0000000000003935","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Aortic pulse wave velocity (aPWV) predicts cardiovascular risk. Being the reference method for aortic stiffness evaluation, invasive aPWV is also recommended for validation of noninvasive devices. Because of intrinsic haemodynamic variability and processing issues, aPWV shows beat-to-beat variability. We aimed to quantify this variability and evaluate its implications for the reliability and use of aPWV as reference in validation and clinical application studies.</p><p><strong>Methods: </strong>The study included n  = 84 patients, in whom two datasets of invasive data were recorded: 1) simultaneous ascending aorta and iliac pressure acquisitions using a dual-tip intra-aortic catheter, and 2) an additional ascending aorta pressure acquisition. By combining the iliac and ascending aorta pressure recordings from the first and second acquisitions, respectively, we evaluated how a sequential acquisition protocol affects variability. We compared three pressure waveform foot identification methods to investigate the effect of data processing on variability. Furthermore, we estimated how averaging over nbeats consecutive heartbeats affects the standard deviation (SD) of such nbeats -averaged estimate of aPWV.</p><p><strong>Results: </strong>The simultaneously acquired invasive aPWV showed a 5% beat-to-beat SD (variability), with small but significant differences between foot identification methods. The sequential acquisition protocol doubled aPWV variability compared to simultaneous acquisition. However, because averaging had a much stronger effect on sequentially measured aPWV, the two acquisition protocols yielded comparable variabilities at nbeats  = 10 (2% vs. 3%).</p><p><strong>Conclusions: </strong>Our study suggests that, independently from the acquisition protocol and data processing, the intrinsic beat-to-beat variability of aPWV becomes manageable when aPWV values of at least ten heartbeats are averaged.</p>","PeriodicalId":16043,"journal":{"name":"Journal of Hypertension","volume":" ","pages":"589-597"},"PeriodicalIF":3.3000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Beat-to-beat variability of aortic pulse wave velocity: implications for aortic stiffness measurements.\",\"authors\":\"Alessandro Giudici, Andrea Grillo, Filippo Scalise, Koen D Reesink, Tammo Delhaas, Paolo Salvi, Bart Spronck, Gianfranco Parati\",\"doi\":\"10.1097/HJH.0000000000003935\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Aortic pulse wave velocity (aPWV) predicts cardiovascular risk. Being the reference method for aortic stiffness evaluation, invasive aPWV is also recommended for validation of noninvasive devices. Because of intrinsic haemodynamic variability and processing issues, aPWV shows beat-to-beat variability. We aimed to quantify this variability and evaluate its implications for the reliability and use of aPWV as reference in validation and clinical application studies.</p><p><strong>Methods: </strong>The study included n  = 84 patients, in whom two datasets of invasive data were recorded: 1) simultaneous ascending aorta and iliac pressure acquisitions using a dual-tip intra-aortic catheter, and 2) an additional ascending aorta pressure acquisition. By combining the iliac and ascending aorta pressure recordings from the first and second acquisitions, respectively, we evaluated how a sequential acquisition protocol affects variability. We compared three pressure waveform foot identification methods to investigate the effect of data processing on variability. Furthermore, we estimated how averaging over nbeats consecutive heartbeats affects the standard deviation (SD) of such nbeats -averaged estimate of aPWV.</p><p><strong>Results: </strong>The simultaneously acquired invasive aPWV showed a 5% beat-to-beat SD (variability), with small but significant differences between foot identification methods. The sequential acquisition protocol doubled aPWV variability compared to simultaneous acquisition. However, because averaging had a much stronger effect on sequentially measured aPWV, the two acquisition protocols yielded comparable variabilities at nbeats  = 10 (2% vs. 3%).</p><p><strong>Conclusions: </strong>Our study suggests that, independently from the acquisition protocol and data processing, the intrinsic beat-to-beat variability of aPWV becomes manageable when aPWV values of at least ten heartbeats are averaged.</p>\",\"PeriodicalId\":16043,\"journal\":{\"name\":\"Journal of Hypertension\",\"volume\":\" \",\"pages\":\"589-597\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2025-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Hypertension\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/HJH.0000000000003935\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2025/2/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hypertension","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/HJH.0000000000003935","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/7 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

目的:主动脉脉波速度(aPWV)预测心血管风险。作为主动脉硬度评估的参考方法,有创aPWV也被推荐用于无创器械的验证。由于固有的血流动力学变异性和处理问题,aPWV表现出搏动间的变异性。我们的目的是量化这种变异性,并评估其对aPWV的可靠性和使用的影响,作为验证和临床应用研究的参考。方法:研究纳入n = 84例患者,记录两组有创数据:1)使用双尖端主动脉内导管同时获得升主动脉和髂动脉压力,2)额外获得升主动脉压力。通过结合第一次和第二次采集的髂动脉和升主动脉压力记录,我们评估了顺序采集方案如何影响变异性。我们比较了三种压力波形脚识别方法,以研究数据处理对变异性的影响。此外,我们估计了超过nbeat连续心跳的平均如何影响这种nbeat -average估计aPWV的标准差(SD)。结果:同时获得的有创aPWV显示出5%的节拍间SD(变异性),不同足部识别方法间差异虽小但显著。与同时采集相比,顺序采集协议使aPWV变异性增加了一倍。然而,由于平均对顺序测量的aPWV有更强的影响,两种采集方案在nbeats = 10时产生了相当的变化(2%对3%)。结论:我们的研究表明,独立于采集方案和数据处理,当平均至少10次心跳的aPWV值时,aPWV的内在搏动变异性变得可控。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Beat-to-beat variability of aortic pulse wave velocity: implications for aortic stiffness measurements.

Objectives: Aortic pulse wave velocity (aPWV) predicts cardiovascular risk. Being the reference method for aortic stiffness evaluation, invasive aPWV is also recommended for validation of noninvasive devices. Because of intrinsic haemodynamic variability and processing issues, aPWV shows beat-to-beat variability. We aimed to quantify this variability and evaluate its implications for the reliability and use of aPWV as reference in validation and clinical application studies.

Methods: The study included n  = 84 patients, in whom two datasets of invasive data were recorded: 1) simultaneous ascending aorta and iliac pressure acquisitions using a dual-tip intra-aortic catheter, and 2) an additional ascending aorta pressure acquisition. By combining the iliac and ascending aorta pressure recordings from the first and second acquisitions, respectively, we evaluated how a sequential acquisition protocol affects variability. We compared three pressure waveform foot identification methods to investigate the effect of data processing on variability. Furthermore, we estimated how averaging over nbeats consecutive heartbeats affects the standard deviation (SD) of such nbeats -averaged estimate of aPWV.

Results: The simultaneously acquired invasive aPWV showed a 5% beat-to-beat SD (variability), with small but significant differences between foot identification methods. The sequential acquisition protocol doubled aPWV variability compared to simultaneous acquisition. However, because averaging had a much stronger effect on sequentially measured aPWV, the two acquisition protocols yielded comparable variabilities at nbeats  = 10 (2% vs. 3%).

Conclusions: Our study suggests that, independently from the acquisition protocol and data processing, the intrinsic beat-to-beat variability of aPWV becomes manageable when aPWV values of at least ten heartbeats are averaged.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Hypertension
Journal of Hypertension 医学-外周血管病
CiteScore
7.90
自引率
6.10%
发文量
1389
审稿时长
3 months
期刊介绍: The Journal of Hypertension publishes papers reporting original clinical and experimental research which are of a high standard and which contribute to the advancement of knowledge in the field of hypertension. The Journal publishes full papers, reviews or editorials (normally by invitation), and correspondence.
期刊最新文献
Beat-to-beat variability of aortic pulse wave velocity: implications for aortic stiffness measurements. Mortality risks in different subtypes of masked hypertension in the Spanish ambulatory blood pressure monitoring registry. Paternal alcohol exposure affected offspring mesenteric artery via ROS-Cacna1c and DNA hypomethylation. Prevalence and correlates of uncontrolled hypertension and cardiovascular morbidity among patients with hypertension at the largest tertiary care hospital in Sri Lanka. Structural and load-dependent arterial stiffness across the adult life span.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1