牙科精度:PLA 3D打印设置如何影响模型精度。

IF 1.3 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie Pub Date : 2024-12-06 DOI:10.1007/s00056-024-00563-w
Louis Hartmann, Verena Passin, Sophie Dürndorfer
{"title":"牙科精度:PLA 3D打印设置如何影响模型精度。","authors":"Louis Hartmann, Verena Passin, Sophie Dürndorfer","doi":"10.1007/s00056-024-00563-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Advancements in computer-aided design and manufacturing (CAD/CAM), such as intraoral scanners, digital treatment planning, and 3D printers, offer digital alternatives to conventional orthodontics. For transforming digital data into a traditional model, precise 3D printing technologies are necessary. With numerous settings available on each 3D printer, selecting the most precise one is challenging. Therefore, the impact of layer height, printing temperature, print speed, and infill density on the accuracy of dental models was analyzed in this study.</p><p><strong>Methods: </strong>A 3D file of a right upper central incisor was designed and printed 275 times in total with different settings for temperature, layer height, print speed, and infill density by using polylactic acid (PLA) filament on an industrial 3D printer. After scanning the models, root mean square error was calculated for analysis of precision. For each group, R<sup>2</sup> value was calculated and linear regression as well as an ANOVA was performed for the factors influencing accuracy.</p><p><strong>Results: </strong>Printing temperature as well as layer height had statistically significant impacts on printing 3D tooth models (p < 0.05). R<sup>2</sup> values of 0.43 for printing temperature as well as of 0.11 for layer height were detected. The infill density as well as the print speed had no statistically significant impacts on accuracy (p > 0.05).</p><p><strong>Conclusion: </strong>This study confirms that choosing the correct printing temperature and layer height for printing dental models with PLA is important for obtaining good accuracy, whereas print speed and infill density have less of an impact.</p>","PeriodicalId":54776,"journal":{"name":"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Precision in dentistry: how PLA 3D printing settings influence model accuracy.\",\"authors\":\"Louis Hartmann, Verena Passin, Sophie Dürndorfer\",\"doi\":\"10.1007/s00056-024-00563-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Advancements in computer-aided design and manufacturing (CAD/CAM), such as intraoral scanners, digital treatment planning, and 3D printers, offer digital alternatives to conventional orthodontics. For transforming digital data into a traditional model, precise 3D printing technologies are necessary. With numerous settings available on each 3D printer, selecting the most precise one is challenging. Therefore, the impact of layer height, printing temperature, print speed, and infill density on the accuracy of dental models was analyzed in this study.</p><p><strong>Methods: </strong>A 3D file of a right upper central incisor was designed and printed 275 times in total with different settings for temperature, layer height, print speed, and infill density by using polylactic acid (PLA) filament on an industrial 3D printer. After scanning the models, root mean square error was calculated for analysis of precision. For each group, R<sup>2</sup> value was calculated and linear regression as well as an ANOVA was performed for the factors influencing accuracy.</p><p><strong>Results: </strong>Printing temperature as well as layer height had statistically significant impacts on printing 3D tooth models (p < 0.05). R<sup>2</sup> values of 0.43 for printing temperature as well as of 0.11 for layer height were detected. The infill density as well as the print speed had no statistically significant impacts on accuracy (p > 0.05).</p><p><strong>Conclusion: </strong>This study confirms that choosing the correct printing temperature and layer height for printing dental models with PLA is important for obtaining good accuracy, whereas print speed and infill density have less of an impact.</p>\",\"PeriodicalId\":54776,\"journal\":{\"name\":\"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-12-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00056-024-00563-w\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00056-024-00563-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:计算机辅助设计和制造(CAD/CAM)的进步,如口腔内扫描仪、数字治疗计划和3D打印机,为传统正畸提供了数字替代方案。为了将数字数据转换为传统模型,精确的3D打印技术是必要的。由于每个3D打印机上都有许多设置,选择最精确的设置是具有挑战性的。因此,本研究分析了层高、打印温度、打印速度、填充密度对牙体模型精度的影响。方法:采用聚乳酸(PLA)长丝在工业3D打印机上设计右上中切牙三维文件,在不同温度、层高、打印速度、填充密度等设置下,共打印275次。对模型进行扫描后,计算均方根误差进行精度分析。对每组进行R2值计算,对影响准确率的因素进行线性回归和方差分析。结果:打印温度和层高对打印3D牙齿模型的影响有统计学意义(p 2),打印温度和层高分别为0.43和0.11。填充密度和打印速度对准确性的影响无统计学意义(p > 0.05)。结论:选择正确的打印温度和层高对于PLA打印牙齿模型获得良好的精度至关重要,而打印速度和填充密度对打印精度的影响较小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Precision in dentistry: how PLA 3D printing settings influence model accuracy.

Purpose: Advancements in computer-aided design and manufacturing (CAD/CAM), such as intraoral scanners, digital treatment planning, and 3D printers, offer digital alternatives to conventional orthodontics. For transforming digital data into a traditional model, precise 3D printing technologies are necessary. With numerous settings available on each 3D printer, selecting the most precise one is challenging. Therefore, the impact of layer height, printing temperature, print speed, and infill density on the accuracy of dental models was analyzed in this study.

Methods: A 3D file of a right upper central incisor was designed and printed 275 times in total with different settings for temperature, layer height, print speed, and infill density by using polylactic acid (PLA) filament on an industrial 3D printer. After scanning the models, root mean square error was calculated for analysis of precision. For each group, R2 value was calculated and linear regression as well as an ANOVA was performed for the factors influencing accuracy.

Results: Printing temperature as well as layer height had statistically significant impacts on printing 3D tooth models (p < 0.05). R2 values of 0.43 for printing temperature as well as of 0.11 for layer height were detected. The infill density as well as the print speed had no statistically significant impacts on accuracy (p > 0.05).

Conclusion: This study confirms that choosing the correct printing temperature and layer height for printing dental models with PLA is important for obtaining good accuracy, whereas print speed and infill density have less of an impact.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.90
自引率
0.00%
发文量
64
审稿时长
>12 weeks
期刊介绍: The Journal of Orofacial Orthopedics provides orthodontists and dentists who are also actively interested in orthodontics, whether in university clinics or private practice, with highly authoritative and up-to-date information based on experimental and clinical research. The journal is one of the leading publications for the promulgation of the results of original work both in the areas of scientific and clinical orthodontics and related areas. All articles undergo peer review before publication. The German Society of Orthodontics (DGKFO) also publishes in the journal important communications, statements and announcements.
期刊最新文献
Accuracy of three-dimensionally printed retainers and aligners : A systematic review. Three-dimensional localization of tooth germs without ionizing radiation : Proof-of-concept study using magnetic resonance imaging. Effects of malocclusion and orthodontic treatment on quality of life among orthodontic patients with craniofacial disorder compared to healthy controls : A cross-sectional study. The IL-17 level in gingival crevicular fluid as an indicator of orthodontically induced inflammatory root resorption. A new harmony box supplemented with gonial angle and age based on a growing Swiss population.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1