{"title":"Clinical Comparison of Decentration and Tilt Effects in Iris-Claw and Trans-scleral Plug Lenses: Wavefront Analysis With a Pyramidal Sensor Aberrometer.","authors":"Lorenzo de Angelis, Vito Romano, Giuseppe Ruben Barbera, Mario Galasso, Jorge L Aliò, Fabrizio Giansanti, Francesco Barca","doi":"10.3928/1081597X-20241009-02","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the aberrometric profile of the Artisan Aphakia lens (Opthec BV) and transscleral plug FIL-SSF lens (Soleko) and to assess the impact of tilt and decentration on their optical performance.</p><p><strong>Methods: </strong>This retrospective observational study was conducted at Azienda Ospedaliera Universitaria Careggi, Florence, Italy, with a consecutive cohort of aphakic eyes undergoing secondary lens implantation with an Artisan or FIL-SSF lens. Wavefront analysis was performed using a pyramidal wavefront-based aberrometer (Osiris-T; CSO). Tilt and decentration were calculated using anterior segment optical coherence tomography (MS-39; CSO).</p><p><strong>Results: </strong>The study included 47 eyes from 45 patients: 24 eyes in the FIL-SSF group and 23 eyes in the Artisan group. Decentration was 0.39 ± 0.14 mm in the FIL-SSF group and 0.51 ± 0.16 mm in the Artisan group (<i>P</i> = .02). The mean tilt value was 6.6 ± 2.35 degrees in the FIL-SSF group and 5.9 ± 1.86 degrees in the Artisan group (<i>P</i> = .13). Internal higher order aberrations (HOAs) were 0.23 ± 0.07 μm in the FIL-SSF group and 0.29 ± 0.13 μm in the Artisan group (<i>P</i> = .02). The point spread function (PSF) Strehl ratio was 0.12 ± 0.05 in the FIL-SSF group and 0.10 ± 0.04 (<i>P</i> = .11) in the Artisan group. The PSF Strehl ratio without lower order aberration (PSFw2) was 0.28 ± 0.12 in the FIL-SSF group and 0.23 ± 0.09 in the Artisan group (<i>P</i> = .01).</p><p><strong>Conclusions: </strong>The Artisan and FIL-SSF lenses provide comparable optical performance in terms of the PSF Strehl ratio. However, the Artisan lens appears to be more susceptible to decentration, which may result in increased higher order aberrations and a consequently lower PSFw2 Strehl ratio. <b>[<i>J Refract Surg</i>. 2024;40(12):e926-e933.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"40 12","pages":"e926-e933"},"PeriodicalIF":2.9000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20241009-02","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较 Artisan Aphakia 镜片(Opthec BV)和经巩膜塞 FIL-SSF 镜片(Soleko)的像差曲线,并评估倾斜和分散对其光学性能的影响:这项回顾性观察研究是在意大利佛罗伦萨 Azienda Ospedaliera Universitaria Careggi 进行的,对象是接受 Artisan 或 FIL-SSF 镜片二次植入手术的无晶体眼。波前分析使用金字塔波前像差仪(Osiris-T;CSO)进行。使用前节光学相干断层扫描(MS-39;CSO)计算倾斜度和分散度:研究包括 45 名患者的 47 只眼睛:结果:研究包括 45 名患者的 47 只眼睛:FIL-SSF 组 24 只,Artisan 组 23 只。FIL-SSF 组的偏斜率为 0.39 ± 0.14 毫米,Artisan 组为 0.51 ± 0.16 毫米(P = 0.02)。FIL-SSF 组的平均倾斜度为 6.6 ± 2.35 度,Artisan 组为 5.9 ± 1.86 度(P = .13)。FIL-SSF 组的内部高阶像差(HOAs)为 0.23 ± 0.07 μm,Artisan 组为 0.29 ± 0.13 μm(P = .02)。FIL-SSF 组的点扩散函数(PSF)Strehl 比为 0.12 ± 0.05,Artisan 组为 0.10 ± 0.04(P = .11)。不含低阶像差的 PSF Strehl 比值(PSFw2),FIL-SSF 组为 0.28 ± 0.12,Artisan 组为 0.23 ± 0.09(P = .01):Artisan和FIL-SSF镜片的PSF Strehl比光学性能相当。然而,Artisan 镜片似乎更容易分散,这可能会导致高阶像差增加,从而降低 PSFw2 Strehl 比值。[J Refract Surg. 2024;40(12):e926-e933]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Clinical Comparison of Decentration and Tilt Effects in Iris-Claw and Trans-scleral Plug Lenses: Wavefront Analysis With a Pyramidal Sensor Aberrometer.

Purpose: To compare the aberrometric profile of the Artisan Aphakia lens (Opthec BV) and transscleral plug FIL-SSF lens (Soleko) and to assess the impact of tilt and decentration on their optical performance.

Methods: This retrospective observational study was conducted at Azienda Ospedaliera Universitaria Careggi, Florence, Italy, with a consecutive cohort of aphakic eyes undergoing secondary lens implantation with an Artisan or FIL-SSF lens. Wavefront analysis was performed using a pyramidal wavefront-based aberrometer (Osiris-T; CSO). Tilt and decentration were calculated using anterior segment optical coherence tomography (MS-39; CSO).

Results: The study included 47 eyes from 45 patients: 24 eyes in the FIL-SSF group and 23 eyes in the Artisan group. Decentration was 0.39 ± 0.14 mm in the FIL-SSF group and 0.51 ± 0.16 mm in the Artisan group (P = .02). The mean tilt value was 6.6 ± 2.35 degrees in the FIL-SSF group and 5.9 ± 1.86 degrees in the Artisan group (P = .13). Internal higher order aberrations (HOAs) were 0.23 ± 0.07 μm in the FIL-SSF group and 0.29 ± 0.13 μm in the Artisan group (P = .02). The point spread function (PSF) Strehl ratio was 0.12 ± 0.05 in the FIL-SSF group and 0.10 ± 0.04 (P = .11) in the Artisan group. The PSF Strehl ratio without lower order aberration (PSFw2) was 0.28 ± 0.12 in the FIL-SSF group and 0.23 ± 0.09 in the Artisan group (P = .01).

Conclusions: The Artisan and FIL-SSF lenses provide comparable optical performance in terms of the PSF Strehl ratio. However, the Artisan lens appears to be more susceptible to decentration, which may result in increased higher order aberrations and a consequently lower PSFw2 Strehl ratio. [J Refract Surg. 2024;40(12):e926-e933.].

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
期刊最新文献
Visual and Safety Outcomes of Refractive Correction Procedures Following Lens Removal for Residual Refractive Error: A Systematic Review and Meta-analysis. 2024 Reviewers. A Nomogram to Improve the Predictability of High Myopic Astigmatism in Small Incision Lenticule Extraction Surgery. Application of the Taylor Diagram in Evaluating the Performance of IOL Formulas. Clarification of Femtosecond Laser Terminology: Energy, Fluence, Dose.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1