角膜交联过程中央区角膜厚度的显微镜集成oct辅助实时监测。

IF 2.9 3区 医学 Q1 OPHTHALMOLOGY Journal of refractive surgery Pub Date : 2024-12-01 DOI:10.3928/1081597X-20241021-02
Nandyala Sushma, Shivam Sharma, Aafreen Bari, Tushar Agarwal, Tanuj Dada, Namrata Sharma
{"title":"角膜交联过程中央区角膜厚度的显微镜集成oct辅助实时监测。","authors":"Nandyala Sushma, Shivam Sharma, Aafreen Bari, Tushar Agarwal, Tanuj Dada, Namrata Sharma","doi":"10.3928/1081597X-20241021-02","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess real-time intraoperative pachymetry changes occurring during corneal cross-linking (CXL) using microscope-integrated optical coherence tomography (Mi-OCT) and compare accuracy of various modalities of pachymetry assessment.</p><p><strong>Methods: </strong>This was a cross-sectional observational comparative study including 45 consecutive patients with progressive keratoconus planned for CXL. Mi-OCT (RESCAN 700) was used to measure central corneal thickness (CCT) during four stages of CXL: before epithelial debridement, after debridement, after riboflavin instillation, and after ultraviolet irradiation. Scheimpflug imaging, anterior segment OCT (AS-OCT), and ultrasound pachymetry were used to assess CCT preoperatively. All data were entered into Excel software (Microsoft Corporation) and analyzed.</p><p><strong>Results: </strong>The CCT significantly decreased after each step of CXL as measured on Mi-OCT (<i>P</i> < .0001). Mi-OCT overestimated the CCT significantly by 1.12 times on average (range: 1.02 to 1.43) compared to ultrasound pachymetry (<i>P</i> = .0004). CCT measured using Scheimpflug imaging and anterior segment OCT was statistically comparable to ultrasound pachymetry.</p><p><strong>Conclusions: </strong>Mi-OCT provides a real-time assessment of CCT during CXL. However, because it overestimates the pachymetry, ultrasound pachymetry remains the gold standard for decision-making during CXL. <b>[<i>J Refract Surg</i>. 2024;40(12):e934-e940.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"40 12","pages":"e934-e940"},"PeriodicalIF":2.9000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Microscope-Integrated OCT-Assisted Real-time Monitoring of Central Corneal Thickness During Corneal Cross-linking.\",\"authors\":\"Nandyala Sushma, Shivam Sharma, Aafreen Bari, Tushar Agarwal, Tanuj Dada, Namrata Sharma\",\"doi\":\"10.3928/1081597X-20241021-02\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To assess real-time intraoperative pachymetry changes occurring during corneal cross-linking (CXL) using microscope-integrated optical coherence tomography (Mi-OCT) and compare accuracy of various modalities of pachymetry assessment.</p><p><strong>Methods: </strong>This was a cross-sectional observational comparative study including 45 consecutive patients with progressive keratoconus planned for CXL. Mi-OCT (RESCAN 700) was used to measure central corneal thickness (CCT) during four stages of CXL: before epithelial debridement, after debridement, after riboflavin instillation, and after ultraviolet irradiation. Scheimpflug imaging, anterior segment OCT (AS-OCT), and ultrasound pachymetry were used to assess CCT preoperatively. All data were entered into Excel software (Microsoft Corporation) and analyzed.</p><p><strong>Results: </strong>The CCT significantly decreased after each step of CXL as measured on Mi-OCT (<i>P</i> < .0001). Mi-OCT overestimated the CCT significantly by 1.12 times on average (range: 1.02 to 1.43) compared to ultrasound pachymetry (<i>P</i> = .0004). CCT measured using Scheimpflug imaging and anterior segment OCT was statistically comparable to ultrasound pachymetry.</p><p><strong>Conclusions: </strong>Mi-OCT provides a real-time assessment of CCT during CXL. However, because it overestimates the pachymetry, ultrasound pachymetry remains the gold standard for decision-making during CXL. <b>[<i>J Refract Surg</i>. 2024;40(12):e934-e940.]</b>.</p>\",\"PeriodicalId\":16951,\"journal\":{\"name\":\"Journal of refractive surgery\",\"volume\":\"40 12\",\"pages\":\"e934-e940\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3928/1081597X-20241021-02\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20241021-02","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:利用显微镜集成光学相干断层扫描(Mi-OCT)评估角膜交联(CXL)术中实时厚测变化,并比较各种厚测评估方式的准确性。方法:这是一项横断面观察性比较研究,包括45例计划进行CXL的进展性圆锥角膜患者。使用Mi-OCT (RESCAN 700)测量CXL四个阶段的角膜中央厚度(CCT):上皮清创前、清创后、核黄素注入后和紫外线照射后。术前应用Scheimpflug显像、前段OCT (AS-OCT)和超声测厚术评估CCT。所有数据输入Excel软件(Microsoft Corporation)进行分析。结果:经Mi-OCT检测,CXL各步骤后CCT均显著降低(P < 0.0001)。与超声测厚术相比,Mi-OCT对CCT的平均高估了1.12倍(范围:1.02 ~ 1.43)(P = 0.0004)。使用Scheimpflug成像和前段OCT测量的CCT在统计学上与超声测厚仪相当。结论:Mi-OCT提供了CXL期间CCT的实时评估。然而,由于超声测厚术高估了测厚术,因此超声测厚术仍然是CXL决策的金标准。[J].中华眼科杂志,2014;35(6):934- 940。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Microscope-Integrated OCT-Assisted Real-time Monitoring of Central Corneal Thickness During Corneal Cross-linking.

Purpose: To assess real-time intraoperative pachymetry changes occurring during corneal cross-linking (CXL) using microscope-integrated optical coherence tomography (Mi-OCT) and compare accuracy of various modalities of pachymetry assessment.

Methods: This was a cross-sectional observational comparative study including 45 consecutive patients with progressive keratoconus planned for CXL. Mi-OCT (RESCAN 700) was used to measure central corneal thickness (CCT) during four stages of CXL: before epithelial debridement, after debridement, after riboflavin instillation, and after ultraviolet irradiation. Scheimpflug imaging, anterior segment OCT (AS-OCT), and ultrasound pachymetry were used to assess CCT preoperatively. All data were entered into Excel software (Microsoft Corporation) and analyzed.

Results: The CCT significantly decreased after each step of CXL as measured on Mi-OCT (P < .0001). Mi-OCT overestimated the CCT significantly by 1.12 times on average (range: 1.02 to 1.43) compared to ultrasound pachymetry (P = .0004). CCT measured using Scheimpflug imaging and anterior segment OCT was statistically comparable to ultrasound pachymetry.

Conclusions: Mi-OCT provides a real-time assessment of CCT during CXL. However, because it overestimates the pachymetry, ultrasound pachymetry remains the gold standard for decision-making during CXL. [J Refract Surg. 2024;40(12):e934-e940.].

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
期刊最新文献
Refractive Outcomes After Scleral Fixation of the Carlevale Intraocular Lens. Reply: Refractive Outcomes After Scleral Fixation of the Carlevale Intraocular Lens. Visual Performance and Patient Satisfaction of Bilaterally Implanted Extended Depth of Focus Intraocular Lens: Outcomes of a Multicenter Registry. Prospective Comparison of Clinical Outcomes After Bilateral Implantation of Diffractive Trifocal Extended Depth-of-Focus and Diffractive Trifocal Hydrophobic Intraocular Lenses. Prospective, Randomized, Contralateral Eye Comparison of the Lenticule Decentration Following SMILE: Coaxially Sighted Corneal Light Reflex Versus Tear Film Mark Centration.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1