通过周期长度和周期长度梯度映射识别维持心房颤动的区域。

IF 2.2 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of Arrhythmia Pub Date : 2024-09-27 DOI:10.1002/joa3.13151
Masafumi Shimojo M.D., Yasuya Inden M.D., Ph.D., Satoshi Yanagisawa M.D., Ph.D., Ryota Yamauchi M.D., Kei Hiramatsu M.D., Tomoya Iwawaki M.D., Masaya Tachi M.D., Shun Kondo M.D., Takayuki Goto M.D., Yukiomi Tsuji M.D., Ph.D., Toyoaki Murohara M.D., Ph.D.
{"title":"通过周期长度和周期长度梯度映射识别维持心房颤动的区域。","authors":"Masafumi Shimojo M.D.,&nbsp;Yasuya Inden M.D., Ph.D.,&nbsp;Satoshi Yanagisawa M.D., Ph.D.,&nbsp;Ryota Yamauchi M.D.,&nbsp;Kei Hiramatsu M.D.,&nbsp;Tomoya Iwawaki M.D.,&nbsp;Masaya Tachi M.D.,&nbsp;Shun Kondo M.D.,&nbsp;Takayuki Goto M.D.,&nbsp;Yukiomi Tsuji M.D., Ph.D.,&nbsp;Toyoaki Murohara M.D., Ph.D.","doi":"10.1002/joa3.13151","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Visualizing the specific regions where atrial fibrillation (AF) is maintained is crucial for effective treatment, but it remains challenging in clinical practice. We aimed to address this challenge by developing a mapping approach focused on the cycle length (CL) and its gradient (CL-gradient).</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>In 105 patients undergoing initial ablation for persistent AF, pre-ablation CARTOFINDER data were utilized to create maps based on three indicators: (1) CL, the atrial frequency during AF calculated using CARTOFINDER; (2) Short CL, encompassing CLs within 5 ms of the minimum CL; and (3) CL-gradient, the CL range within a 6 mm radius. We evaluated the association between the AF termination through ablation and the measured values and patterns in each map.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>AF termination occurred in 17 patients. The AF termination group exhibited the significant large maximum CL-gradient (48.8 ms [interquartile range, 38.6–66.3], <i>p</i> &lt;.001) and the short distance between the minimum CL site and the maximum CL-gradient site (15.8 mm, [interquartile range, 6.0–23.2], <i>p</i> =.029). Of the 17 AF termination cases, 13 exhibited a CL distribution pattern characterized by a steep CL-gradient near the minimum CL site (SG-MCL), defined as the distance of less than 23.2 mm and the maximum CL-gradient greater than 33.1 ms. In these AF termination cases, SG-MCL was also correlated with the ablation area.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The minimum CL area accompanied by significant CL gradients in the immediate vicinity may play a crucial role in sustaining AF.</p>\n </section>\n </div>","PeriodicalId":15174,"journal":{"name":"Journal of Arrhythmia","volume":"40 6","pages":"1389-1399"},"PeriodicalIF":2.2000,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11632248/pdf/","citationCount":"0","resultStr":"{\"title\":\"Identification of regions maintaining atrial fibrillation through cycle length and cycle length gradient mapping\",\"authors\":\"Masafumi Shimojo M.D.,&nbsp;Yasuya Inden M.D., Ph.D.,&nbsp;Satoshi Yanagisawa M.D., Ph.D.,&nbsp;Ryota Yamauchi M.D.,&nbsp;Kei Hiramatsu M.D.,&nbsp;Tomoya Iwawaki M.D.,&nbsp;Masaya Tachi M.D.,&nbsp;Shun Kondo M.D.,&nbsp;Takayuki Goto M.D.,&nbsp;Yukiomi Tsuji M.D., Ph.D.,&nbsp;Toyoaki Murohara M.D., Ph.D.\",\"doi\":\"10.1002/joa3.13151\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>Visualizing the specific regions where atrial fibrillation (AF) is maintained is crucial for effective treatment, but it remains challenging in clinical practice. We aimed to address this challenge by developing a mapping approach focused on the cycle length (CL) and its gradient (CL-gradient).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>In 105 patients undergoing initial ablation for persistent AF, pre-ablation CARTOFINDER data were utilized to create maps based on three indicators: (1) CL, the atrial frequency during AF calculated using CARTOFINDER; (2) Short CL, encompassing CLs within 5 ms of the minimum CL; and (3) CL-gradient, the CL range within a 6 mm radius. We evaluated the association between the AF termination through ablation and the measured values and patterns in each map.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>AF termination occurred in 17 patients. The AF termination group exhibited the significant large maximum CL-gradient (48.8 ms [interquartile range, 38.6–66.3], <i>p</i> &lt;.001) and the short distance between the minimum CL site and the maximum CL-gradient site (15.8 mm, [interquartile range, 6.0–23.2], <i>p</i> =.029). Of the 17 AF termination cases, 13 exhibited a CL distribution pattern characterized by a steep CL-gradient near the minimum CL site (SG-MCL), defined as the distance of less than 23.2 mm and the maximum CL-gradient greater than 33.1 ms. In these AF termination cases, SG-MCL was also correlated with the ablation area.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>The minimum CL area accompanied by significant CL gradients in the immediate vicinity may play a crucial role in sustaining AF.</p>\\n </section>\\n </div>\",\"PeriodicalId\":15174,\"journal\":{\"name\":\"Journal of Arrhythmia\",\"volume\":\"40 6\",\"pages\":\"1389-1399\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11632248/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Arrhythmia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/joa3.13151\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/joa3.13151","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:可视化房颤(AF)维持的特定区域对于有效治疗至关重要,但在临床实践中仍然具有挑战性。我们的目标是通过开发一种专注于周期长度(CL)及其梯度(CL-梯度)的映射方法来解决这一挑战。方法:对105例持续性房颤初始消融患者,利用消融前的CARTOFINDER数据,基于三个指标制作房颤图:(1)CL,即房颤期间使用CARTOFINDER计算的房频;(2)短极限极限,包括距离最小极限极限5毫秒内的极限极限;(3) CL梯度,CL范围在6mm半径内。我们评估了消融引起的房颤终止与每个图谱的测量值和模式之间的关系。结果:17例患者房颤终止。房颤终止组最大cl梯度显著增大(48.8 ms[四分位数间距,38.6-66.3],p p = 0.029)。在17例AF终止病例中,13例的CL分布模式为最小CL位点(SG-MCL)附近CL梯度陡,定义为距离小于23.2 mm,最大CL梯度大于33.1 ms。在这些房颤终止病例中,SG-MCL也与消融面积相关。结论:在房颤的维持中,最小的CL面积和附近明显的CL梯度可能起着至关重要的作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Identification of regions maintaining atrial fibrillation through cycle length and cycle length gradient mapping

Background

Visualizing the specific regions where atrial fibrillation (AF) is maintained is crucial for effective treatment, but it remains challenging in clinical practice. We aimed to address this challenge by developing a mapping approach focused on the cycle length (CL) and its gradient (CL-gradient).

Methods

In 105 patients undergoing initial ablation for persistent AF, pre-ablation CARTOFINDER data were utilized to create maps based on three indicators: (1) CL, the atrial frequency during AF calculated using CARTOFINDER; (2) Short CL, encompassing CLs within 5 ms of the minimum CL; and (3) CL-gradient, the CL range within a 6 mm radius. We evaluated the association between the AF termination through ablation and the measured values and patterns in each map.

Results

AF termination occurred in 17 patients. The AF termination group exhibited the significant large maximum CL-gradient (48.8 ms [interquartile range, 38.6–66.3], p <.001) and the short distance between the minimum CL site and the maximum CL-gradient site (15.8 mm, [interquartile range, 6.0–23.2], p =.029). Of the 17 AF termination cases, 13 exhibited a CL distribution pattern characterized by a steep CL-gradient near the minimum CL site (SG-MCL), defined as the distance of less than 23.2 mm and the maximum CL-gradient greater than 33.1 ms. In these AF termination cases, SG-MCL was also correlated with the ablation area.

Conclusions

The minimum CL area accompanied by significant CL gradients in the immediate vicinity may play a crucial role in sustaining AF.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Arrhythmia
Journal of Arrhythmia CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
10.00%
发文量
127
审稿时长
45 weeks
期刊最新文献
Single snare pushing technique: A new bailout technique for retrieving Micra fixed in the tricuspid valve annulus Number needed to treat for net clinical benefit of oral anticoagulants in Asian patients with atrial fibrillation Electrocardiographic imaging metrics to predict the risk of arrhythmia in patients with ischemic cardiomyopathy Impact of baseline-pool local impedance on lesion formation using a local impedance-sensing catheter: Lessons from a porcine experimental model Effectiveness of upgrade left bundle branch area pacing for right ventricular pacing-induced cardiomyopathy: Extra QRS shortening matters
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1