Denis E. Bergeron , Gulakhshan Hamad , Brittany A. Broder , Jeffrey T. Cessna , Adam J. Pearce , Jerome LaRosa , Leticia Pibida , Rhys Salter , Neha S. Saxena , Brian E. Zimmerman
{"title":"225Ac及其子代放射性平衡的活度测量与校准。","authors":"Denis E. Bergeron , Gulakhshan Hamad , Brittany A. Broder , Jeffrey T. Cessna , Adam J. Pearce , Jerome LaRosa , Leticia Pibida , Rhys Salter , Neha S. Saxena , Brian E. Zimmerman","doi":"10.1016/j.apradiso.2024.111630","DOIUrl":null,"url":null,"abstract":"<div><div>The massic activity of <sup>225</sup>Ac in 0.1 mol/L HCl was measured by multiple primary methods over four consistent measurement campaigns. Results from the triple-to-double coincidence ratio (TDCR) method of liquid scintillation (LS) counting were in accord with other LS-based primary methods. The calibration of commercial radionuclide calibrators (“dose calibrators”) is described, with discussion of current literature values. Comparisons between experimental ionization chamber and NaI(Tl) well counter responses and benchmarked Monte Carlo models are addressed.</div></div>","PeriodicalId":8096,"journal":{"name":"Applied Radiation and Isotopes","volume":"217 ","pages":"Article 111630"},"PeriodicalIF":1.6000,"publicationDate":"2024-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Activity measurements and calibrations for 225Ac in radioactive equilibrium with its progeny\",\"authors\":\"Denis E. Bergeron , Gulakhshan Hamad , Brittany A. Broder , Jeffrey T. Cessna , Adam J. Pearce , Jerome LaRosa , Leticia Pibida , Rhys Salter , Neha S. Saxena , Brian E. Zimmerman\",\"doi\":\"10.1016/j.apradiso.2024.111630\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The massic activity of <sup>225</sup>Ac in 0.1 mol/L HCl was measured by multiple primary methods over four consistent measurement campaigns. Results from the triple-to-double coincidence ratio (TDCR) method of liquid scintillation (LS) counting were in accord with other LS-based primary methods. The calibration of commercial radionuclide calibrators (“dose calibrators”) is described, with discussion of current literature values. Comparisons between experimental ionization chamber and NaI(Tl) well counter responses and benchmarked Monte Carlo models are addressed.</div></div>\",\"PeriodicalId\":8096,\"journal\":{\"name\":\"Applied Radiation and Isotopes\",\"volume\":\"217 \",\"pages\":\"Article 111630\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-12-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Radiation and Isotopes\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0969804324004585\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, INORGANIC & NUCLEAR\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Radiation and Isotopes","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0969804324004585","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
Activity measurements and calibrations for 225Ac in radioactive equilibrium with its progeny
The massic activity of 225Ac in 0.1 mol/L HCl was measured by multiple primary methods over four consistent measurement campaigns. Results from the triple-to-double coincidence ratio (TDCR) method of liquid scintillation (LS) counting were in accord with other LS-based primary methods. The calibration of commercial radionuclide calibrators (“dose calibrators”) is described, with discussion of current literature values. Comparisons between experimental ionization chamber and NaI(Tl) well counter responses and benchmarked Monte Carlo models are addressed.
期刊介绍:
Applied Radiation and Isotopes provides a high quality medium for the publication of substantial, original and scientific and technological papers on the development and peaceful application of nuclear, radiation and radionuclide techniques in chemistry, physics, biochemistry, biology, medicine, security, engineering and in the earth, planetary and environmental sciences, all including dosimetry. Nuclear techniques are defined in the broadest sense and both experimental and theoretical papers are welcome. They include the development and use of α- and β-particles, X-rays and γ-rays, neutrons and other nuclear particles and radiations from all sources, including radionuclides, synchrotron sources, cyclotrons and reactors and from the natural environment.
The journal aims to publish papers with significance to an international audience, containing substantial novelty and scientific impact. The Editors reserve the rights to reject, with or without external review, papers that do not meet these criteria.
Papers dealing with radiation processing, i.e., where radiation is used to bring about a biological, chemical or physical change in a material, should be directed to our sister journal Radiation Physics and Chemistry.