与普通预警系统相比,产科特异性预警系统用于预测严重的产后产妇发病率。

0 MEDICINE, RESEARCH & EXPERIMENTAL Biomolecules & biomedicine Pub Date : 2025-05-08 DOI:10.17305/bb.2024.11679
Neža Pezdirc, Tatjana Stopar Pintarič, Miha Lučovnik
{"title":"与普通预警系统相比,产科特异性预警系统用于预测严重的产后产妇发病率。","authors":"Neža Pezdirc, Tatjana Stopar Pintarič, Miha Lučovnik","doi":"10.17305/bb.2024.11679","DOIUrl":null,"url":null,"abstract":"<p><p>Severe maternal morbidity is a major global health concern, and early identification of at-risk postpartum women is essential to improving outcomes. We aimed to compare the predictive values of the Modified Early Obstetric Warning System (MEOWS) versus the non-obstetric general Early Warning System (EWS) for predicting severe maternal morbidity in postpartum women. We retrospectively reviewed hospital documentation of 723 postpartum women admitted to the obstetric high dependency unit between October 2020 and March 2021. Severe maternal morbidity was defined using the American College of Obstetricians and Gynecologists' criteria. We assessed the sensitivity, specificity, positive and negative predictive values, as well as positive and negative likelihood ratios, of the MEOWS and the EWS for predicting severe postpartum maternal morbidity. Twenty-four (3.3%) women included in the study met the criteria for severe maternal morbidity. Hypertensive complications and obstetric haemorrhage were the most prevalent causes of maternal morbidity. The sensitivity of the MEOWS was 92%, specificity 62%, positive predictive value 8%, and negative predictive value 100%. The positive likelihood ratio was 2.4, while the negative likelihood ratio was 0.1. In comparison, the EWS had a sensitivity of 63%, specificity of 66%, positive predictive value of 6%, and negative predictive value of 98%. The positive likelihood ratio for the EWS was 1.8, and the negative likelihood ratio was 0.6. The obstetric-specific early warning system proved to be superior for the early prediction of severe postpartum maternal morbidity compared to the general non-obstetric warning system.</p>","PeriodicalId":72398,"journal":{"name":"Biomolecules & biomedicine","volume":" ","pages":"1517-1521"},"PeriodicalIF":0.0000,"publicationDate":"2025-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12097397/pdf/","citationCount":"0","resultStr":"{\"title\":\"Obstetric-specific compared to general early warning system for predicting severe postpartum maternal morbidity.\",\"authors\":\"Neža Pezdirc, Tatjana Stopar Pintarič, Miha Lučovnik\",\"doi\":\"10.17305/bb.2024.11679\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Severe maternal morbidity is a major global health concern, and early identification of at-risk postpartum women is essential to improving outcomes. We aimed to compare the predictive values of the Modified Early Obstetric Warning System (MEOWS) versus the non-obstetric general Early Warning System (EWS) for predicting severe maternal morbidity in postpartum women. We retrospectively reviewed hospital documentation of 723 postpartum women admitted to the obstetric high dependency unit between October 2020 and March 2021. Severe maternal morbidity was defined using the American College of Obstetricians and Gynecologists' criteria. We assessed the sensitivity, specificity, positive and negative predictive values, as well as positive and negative likelihood ratios, of the MEOWS and the EWS for predicting severe postpartum maternal morbidity. Twenty-four (3.3%) women included in the study met the criteria for severe maternal morbidity. Hypertensive complications and obstetric haemorrhage were the most prevalent causes of maternal morbidity. The sensitivity of the MEOWS was 92%, specificity 62%, positive predictive value 8%, and negative predictive value 100%. The positive likelihood ratio was 2.4, while the negative likelihood ratio was 0.1. In comparison, the EWS had a sensitivity of 63%, specificity of 66%, positive predictive value of 6%, and negative predictive value of 98%. The positive likelihood ratio for the EWS was 1.8, and the negative likelihood ratio was 0.6. The obstetric-specific early warning system proved to be superior for the early prediction of severe postpartum maternal morbidity compared to the general non-obstetric warning system.</p>\",\"PeriodicalId\":72398,\"journal\":{\"name\":\"Biomolecules & biomedicine\",\"volume\":\" \",\"pages\":\"1517-1521\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-05-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12097397/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomolecules & biomedicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17305/bb.2024.11679\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"0\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomolecules & biomedicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17305/bb.2024.11679","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

严重的孕产妇发病率是一个主要的全球健康问题,早期发现有风险的产后妇女对于改善结果至关重要。我们的目的是比较改良早期产科预警系统(MEOWS)与非产科一般早期预警系统(EWS)在预测产后妇女严重产妇发病率方面的预测价值。我们回顾性地回顾了2020年10月至2021年3月期间入住产科高依赖性病房的723名产后妇女的医院文件。严重的产妇发病率是根据美国妇产科医师学会的标准来定义的。我们评估了MEOWS和EWS预测严重产后产妇发病率的敏感性、特异性、阳性和阴性预测值以及阳性和阴性似然比。纳入研究的24名妇女(3.3%)符合严重孕产妇发病率的标准。高血压并发症和产科出血是产妇发病的最常见原因。MEOWS的敏感性为92%,特异性62%,阳性预测值为8%,阴性预测值为100%。正似然比为2.4,负似然比为0.1。相比之下,EWS的敏感性为63%,特异性为66%,阳性预测值为6%,阴性预测值为98%。EWS阳性似然比为1.8,负似然比为0.6。事实证明,与一般的非产科预警系统相比,产科特异性预警系统在早期预测严重产后孕产妇发病率方面具有优越性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Obstetric-specific compared to general early warning system for predicting severe postpartum maternal morbidity.

Severe maternal morbidity is a major global health concern, and early identification of at-risk postpartum women is essential to improving outcomes. We aimed to compare the predictive values of the Modified Early Obstetric Warning System (MEOWS) versus the non-obstetric general Early Warning System (EWS) for predicting severe maternal morbidity in postpartum women. We retrospectively reviewed hospital documentation of 723 postpartum women admitted to the obstetric high dependency unit between October 2020 and March 2021. Severe maternal morbidity was defined using the American College of Obstetricians and Gynecologists' criteria. We assessed the sensitivity, specificity, positive and negative predictive values, as well as positive and negative likelihood ratios, of the MEOWS and the EWS for predicting severe postpartum maternal morbidity. Twenty-four (3.3%) women included in the study met the criteria for severe maternal morbidity. Hypertensive complications and obstetric haemorrhage were the most prevalent causes of maternal morbidity. The sensitivity of the MEOWS was 92%, specificity 62%, positive predictive value 8%, and negative predictive value 100%. The positive likelihood ratio was 2.4, while the negative likelihood ratio was 0.1. In comparison, the EWS had a sensitivity of 63%, specificity of 66%, positive predictive value of 6%, and negative predictive value of 98%. The positive likelihood ratio for the EWS was 1.8, and the negative likelihood ratio was 0.6. The obstetric-specific early warning system proved to be superior for the early prediction of severe postpartum maternal morbidity compared to the general non-obstetric warning system.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
0
期刊最新文献
Letter regarding "Survival outcomes and prognostic nomogram for primary pulmonary MALT lymphoma and diffuse large B-cell lymphoma: A SEER database study". Butyl and isobutyl ortho-coumaric acid derivatives reduce self-renewal and MGMT expression in GBM cells with stem cell-like characteristics in vitro. ZNF469 drives TGF-β1/SMAD3-mediated extracellular matrix regulation in pulmonary fibrosis. Neutrophil-to-lymphocyte ratio as a prognostic biomarker in lung cancer patients treated with PD-1/PD-L1 inhibitors: A systematic review and meta-analysis. Morphine-induced hepatotoxicity in rats: Sex and dose variations in liver enzymes, oxidative stress, inflammation, apoptosis, and histopathology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1