Anna Pfenniger, Thorald Stolte, Jakob Johannes Reichl, Gregor Leibundgut, Max Wagener, Christoph Kaiser, Jasper Boeddinghaus, Felix Mahfoud, Thomas Nestelberger
{"title":"TAVI前后有创和无创梯度的比较及其对临床结果的影响。","authors":"Anna Pfenniger, Thorald Stolte, Jakob Johannes Reichl, Gregor Leibundgut, Max Wagener, Christoph Kaiser, Jasper Boeddinghaus, Felix Mahfoud, Thomas Nestelberger","doi":"10.1007/s12928-024-01074-6","DOIUrl":null,"url":null,"abstract":"<p><p>Transcatheter aortic valve implantation (TAVI) is recommended for treatment of high-risk aortic stenosis patients. While measuring mean transaortic valve gradient (MG) is crucial in evaluating procedural success, echocardiographic measurements often overestimate direct invasive measurements. This study aimed to examine the discordance between echocardiographic and invasive MGs in TAVI patients and assess their prognostic value on long-term outcomes. This prospective registry included consecutive TAVI patients at a tertiary university hospital. Transthoracic or transoesophageal echocardiography was performed pre-TAVI, at discharge, 1 month, 1, and 5 years with invasive MG measurements obtained peri-procedurally. The primary endpoints were 5-year all-cause mortality and major adverse cardiac events. Among 1353 patients from 2011 to 2023, non-invasive MGs exceeded invasive MGs pre- and post-implantation (43 [36, 52] mmHg vs. 40 [30, 50] mmHg, p < 0.001; 9 [6, 12] mmHg vs. 4 [2, 7] mmHg, p < 0.001) Pre-procedural MGs correlated better than post-procedural MGs (r = 0.70, p < 0.001 vs. r = 0.23, p < 0.001), particularly in self-expandable valves and smaller sinus of Valsalva diameter (SOVd) (r = 0.33, p < 0.001; r = 0.46, p < 0.001 vs R = 0.06, p = 0.701). Non-invasive MG remained stable from discharge (9 [6, 12] mmHg) to 5 years (9 [7, 12] mmHg). While structural valve deterioration and patient-prosthesis mismatch showed no impact, extreme invasive MGs (< 3 or > 6 mmHg) predicted worse outcomes (mortality hazard: 1.25 [1.06, 1.88] and 0.85 [0.8, 0.95], respectively), unlike non-invasive measurements. In conclusion, invasive as compared with non-invasive MGs correlated better before than after valve implantation, whereas invasive MGs were always lower than non-invasive MGs. Lower invasive MGs after TAVI appeared to be associated with favourable long-term outcomes.</p>","PeriodicalId":9439,"journal":{"name":"Cardiovascular Intervention and Therapeutics","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of invasive and non-invasive gradients before and after TAVI and their implications on clinical outcomes.\",\"authors\":\"Anna Pfenniger, Thorald Stolte, Jakob Johannes Reichl, Gregor Leibundgut, Max Wagener, Christoph Kaiser, Jasper Boeddinghaus, Felix Mahfoud, Thomas Nestelberger\",\"doi\":\"10.1007/s12928-024-01074-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Transcatheter aortic valve implantation (TAVI) is recommended for treatment of high-risk aortic stenosis patients. While measuring mean transaortic valve gradient (MG) is crucial in evaluating procedural success, echocardiographic measurements often overestimate direct invasive measurements. This study aimed to examine the discordance between echocardiographic and invasive MGs in TAVI patients and assess their prognostic value on long-term outcomes. This prospective registry included consecutive TAVI patients at a tertiary university hospital. Transthoracic or transoesophageal echocardiography was performed pre-TAVI, at discharge, 1 month, 1, and 5 years with invasive MG measurements obtained peri-procedurally. The primary endpoints were 5-year all-cause mortality and major adverse cardiac events. Among 1353 patients from 2011 to 2023, non-invasive MGs exceeded invasive MGs pre- and post-implantation (43 [36, 52] mmHg vs. 40 [30, 50] mmHg, p < 0.001; 9 [6, 12] mmHg vs. 4 [2, 7] mmHg, p < 0.001) Pre-procedural MGs correlated better than post-procedural MGs (r = 0.70, p < 0.001 vs. r = 0.23, p < 0.001), particularly in self-expandable valves and smaller sinus of Valsalva diameter (SOVd) (r = 0.33, p < 0.001; r = 0.46, p < 0.001 vs R = 0.06, p = 0.701). Non-invasive MG remained stable from discharge (9 [6, 12] mmHg) to 5 years (9 [7, 12] mmHg). While structural valve deterioration and patient-prosthesis mismatch showed no impact, extreme invasive MGs (< 3 or > 6 mmHg) predicted worse outcomes (mortality hazard: 1.25 [1.06, 1.88] and 0.85 [0.8, 0.95], respectively), unlike non-invasive measurements. In conclusion, invasive as compared with non-invasive MGs correlated better before than after valve implantation, whereas invasive MGs were always lower than non-invasive MGs. Lower invasive MGs after TAVI appeared to be associated with favourable long-term outcomes.</p>\",\"PeriodicalId\":9439,\"journal\":{\"name\":\"Cardiovascular Intervention and Therapeutics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Intervention and Therapeutics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s12928-024-01074-6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Intervention and Therapeutics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12928-024-01074-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
摘要
经导管主动脉瓣植入术(TAVI)被推荐用于治疗高危主动脉瓣狭窄患者。虽然测量平均经主动脉瓣梯度(MG)是评估手术成功的关键,超声心动图测量往往高估直接侵入性测量。本研究旨在探讨TAVI患者超声心动图与有创心电图的不一致性,并评估其对长期预后的预测价值。这项前瞻性登记包括一家三级大学医院的连续TAVI患者。经胸或经食管超声心动图分别在tavi前、出院时、1个月、1年和5年进行,并在术中进行有创MG测量。主要终点是5年全因死亡率和主要心脏不良事件。在2011年至2023年的1353例患者中,与非侵入性测量不同,非侵入性mg值高于植入前和植入后的有创mg值(43 [36,52]mmHg vs. 40 [30,50] mmHg, p 6 mmHg)预测的结果更差(死亡率风险分别为1.25[1.06,1.88]和0.85[0.8,0.95])。综上所述,瓣膜置入术前有创性与无创性心电图相关性好于瓣膜置入术后,但有创性心电图始终低于无创性。TAVI后较低的侵袭性mg似乎与良好的长期预后有关。
Comparison of invasive and non-invasive gradients before and after TAVI and their implications on clinical outcomes.
Transcatheter aortic valve implantation (TAVI) is recommended for treatment of high-risk aortic stenosis patients. While measuring mean transaortic valve gradient (MG) is crucial in evaluating procedural success, echocardiographic measurements often overestimate direct invasive measurements. This study aimed to examine the discordance between echocardiographic and invasive MGs in TAVI patients and assess their prognostic value on long-term outcomes. This prospective registry included consecutive TAVI patients at a tertiary university hospital. Transthoracic or transoesophageal echocardiography was performed pre-TAVI, at discharge, 1 month, 1, and 5 years with invasive MG measurements obtained peri-procedurally. The primary endpoints were 5-year all-cause mortality and major adverse cardiac events. Among 1353 patients from 2011 to 2023, non-invasive MGs exceeded invasive MGs pre- and post-implantation (43 [36, 52] mmHg vs. 40 [30, 50] mmHg, p < 0.001; 9 [6, 12] mmHg vs. 4 [2, 7] mmHg, p < 0.001) Pre-procedural MGs correlated better than post-procedural MGs (r = 0.70, p < 0.001 vs. r = 0.23, p < 0.001), particularly in self-expandable valves and smaller sinus of Valsalva diameter (SOVd) (r = 0.33, p < 0.001; r = 0.46, p < 0.001 vs R = 0.06, p = 0.701). Non-invasive MG remained stable from discharge (9 [6, 12] mmHg) to 5 years (9 [7, 12] mmHg). While structural valve deterioration and patient-prosthesis mismatch showed no impact, extreme invasive MGs (< 3 or > 6 mmHg) predicted worse outcomes (mortality hazard: 1.25 [1.06, 1.88] and 0.85 [0.8, 0.95], respectively), unlike non-invasive measurements. In conclusion, invasive as compared with non-invasive MGs correlated better before than after valve implantation, whereas invasive MGs were always lower than non-invasive MGs. Lower invasive MGs after TAVI appeared to be associated with favourable long-term outcomes.
期刊介绍:
Cardiovascular Intervention and Therapeutics (CVIT) is an international journal covering the field of cardiovascular disease and includes cardiac (coronary and noncoronary) and peripheral interventions and therapeutics. Articles are subject to peer review and complete editorial evaluation prior to any decision regarding acceptability. CVIT is an official journal of The Japanese Association of Cardiovascular Intervention and Therapeutics.