TAVI前后有创和无创梯度的比较及其对临床结果的影响。

IF 3.1 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS Cardiovascular Intervention and Therapeutics Pub Date : 2024-12-19 DOI:10.1007/s12928-024-01074-6
Anna Pfenniger, Thorald Stolte, Jakob Johannes Reichl, Gregor Leibundgut, Max Wagener, Christoph Kaiser, Jasper Boeddinghaus, Felix Mahfoud, Thomas Nestelberger
{"title":"TAVI前后有创和无创梯度的比较及其对临床结果的影响。","authors":"Anna Pfenniger, Thorald Stolte, Jakob Johannes Reichl, Gregor Leibundgut, Max Wagener, Christoph Kaiser, Jasper Boeddinghaus, Felix Mahfoud, Thomas Nestelberger","doi":"10.1007/s12928-024-01074-6","DOIUrl":null,"url":null,"abstract":"<p><p>Transcatheter aortic valve implantation (TAVI) is recommended for treatment of high-risk aortic stenosis patients. While measuring mean transaortic valve gradient (MG) is crucial in evaluating procedural success, echocardiographic measurements often overestimate direct invasive measurements. This study aimed to examine the discordance between echocardiographic and invasive MGs in TAVI patients and assess their prognostic value on long-term outcomes. This prospective registry included consecutive TAVI patients at a tertiary university hospital. Transthoracic or transoesophageal echocardiography was performed pre-TAVI, at discharge, 1 month, 1, and 5 years with invasive MG measurements obtained peri-procedurally. The primary endpoints were 5-year all-cause mortality and major adverse cardiac events. Among 1353 patients from 2011 to 2023, non-invasive MGs exceeded invasive MGs pre- and post-implantation (43 [36, 52] mmHg vs. 40 [30, 50] mmHg, p < 0.001; 9 [6, 12] mmHg vs. 4 [2, 7] mmHg, p < 0.001) Pre-procedural MGs correlated better than post-procedural MGs (r = 0.70, p < 0.001 vs. r = 0.23, p < 0.001), particularly in self-expandable valves and smaller sinus of Valsalva diameter (SOVd) (r = 0.33, p < 0.001; r = 0.46, p < 0.001 vs R = 0.06, p = 0.701). Non-invasive MG remained stable from discharge (9 [6, 12] mmHg) to 5 years (9 [7, 12] mmHg). While structural valve deterioration and patient-prosthesis mismatch showed no impact, extreme invasive MGs (< 3 or > 6 mmHg) predicted worse outcomes (mortality hazard: 1.25 [1.06, 1.88] and 0.85 [0.8, 0.95], respectively), unlike non-invasive measurements. In conclusion, invasive as compared with non-invasive MGs correlated better before than after valve implantation, whereas invasive MGs were always lower than non-invasive MGs. Lower invasive MGs after TAVI appeared to be associated with favourable long-term outcomes.</p>","PeriodicalId":9439,"journal":{"name":"Cardiovascular Intervention and Therapeutics","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of invasive and non-invasive gradients before and after TAVI and their implications on clinical outcomes.\",\"authors\":\"Anna Pfenniger, Thorald Stolte, Jakob Johannes Reichl, Gregor Leibundgut, Max Wagener, Christoph Kaiser, Jasper Boeddinghaus, Felix Mahfoud, Thomas Nestelberger\",\"doi\":\"10.1007/s12928-024-01074-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Transcatheter aortic valve implantation (TAVI) is recommended for treatment of high-risk aortic stenosis patients. While measuring mean transaortic valve gradient (MG) is crucial in evaluating procedural success, echocardiographic measurements often overestimate direct invasive measurements. This study aimed to examine the discordance between echocardiographic and invasive MGs in TAVI patients and assess their prognostic value on long-term outcomes. This prospective registry included consecutive TAVI patients at a tertiary university hospital. Transthoracic or transoesophageal echocardiography was performed pre-TAVI, at discharge, 1 month, 1, and 5 years with invasive MG measurements obtained peri-procedurally. The primary endpoints were 5-year all-cause mortality and major adverse cardiac events. Among 1353 patients from 2011 to 2023, non-invasive MGs exceeded invasive MGs pre- and post-implantation (43 [36, 52] mmHg vs. 40 [30, 50] mmHg, p < 0.001; 9 [6, 12] mmHg vs. 4 [2, 7] mmHg, p < 0.001) Pre-procedural MGs correlated better than post-procedural MGs (r = 0.70, p < 0.001 vs. r = 0.23, p < 0.001), particularly in self-expandable valves and smaller sinus of Valsalva diameter (SOVd) (r = 0.33, p < 0.001; r = 0.46, p < 0.001 vs R = 0.06, p = 0.701). Non-invasive MG remained stable from discharge (9 [6, 12] mmHg) to 5 years (9 [7, 12] mmHg). While structural valve deterioration and patient-prosthesis mismatch showed no impact, extreme invasive MGs (< 3 or > 6 mmHg) predicted worse outcomes (mortality hazard: 1.25 [1.06, 1.88] and 0.85 [0.8, 0.95], respectively), unlike non-invasive measurements. In conclusion, invasive as compared with non-invasive MGs correlated better before than after valve implantation, whereas invasive MGs were always lower than non-invasive MGs. Lower invasive MGs after TAVI appeared to be associated with favourable long-term outcomes.</p>\",\"PeriodicalId\":9439,\"journal\":{\"name\":\"Cardiovascular Intervention and Therapeutics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Intervention and Therapeutics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s12928-024-01074-6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Intervention and Therapeutics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12928-024-01074-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

经导管主动脉瓣植入术(TAVI)被推荐用于治疗高危主动脉瓣狭窄患者。虽然测量平均经主动脉瓣梯度(MG)是评估手术成功的关键,超声心动图测量往往高估直接侵入性测量。本研究旨在探讨TAVI患者超声心动图与有创心电图的不一致性,并评估其对长期预后的预测价值。这项前瞻性登记包括一家三级大学医院的连续TAVI患者。经胸或经食管超声心动图分别在tavi前、出院时、1个月、1年和5年进行,并在术中进行有创MG测量。主要终点是5年全因死亡率和主要心脏不良事件。在2011年至2023年的1353例患者中,与非侵入性测量不同,非侵入性mg值高于植入前和植入后的有创mg值(43 [36,52]mmHg vs. 40 [30,50] mmHg, p 6 mmHg)预测的结果更差(死亡率风险分别为1.25[1.06,1.88]和0.85[0.8,0.95])。综上所述,瓣膜置入术前有创性与无创性心电图相关性好于瓣膜置入术后,但有创性心电图始终低于无创性。TAVI后较低的侵袭性mg似乎与良好的长期预后有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of invasive and non-invasive gradients before and after TAVI and their implications on clinical outcomes.

Transcatheter aortic valve implantation (TAVI) is recommended for treatment of high-risk aortic stenosis patients. While measuring mean transaortic valve gradient (MG) is crucial in evaluating procedural success, echocardiographic measurements often overestimate direct invasive measurements. This study aimed to examine the discordance between echocardiographic and invasive MGs in TAVI patients and assess their prognostic value on long-term outcomes. This prospective registry included consecutive TAVI patients at a tertiary university hospital. Transthoracic or transoesophageal echocardiography was performed pre-TAVI, at discharge, 1 month, 1, and 5 years with invasive MG measurements obtained peri-procedurally. The primary endpoints were 5-year all-cause mortality and major adverse cardiac events. Among 1353 patients from 2011 to 2023, non-invasive MGs exceeded invasive MGs pre- and post-implantation (43 [36, 52] mmHg vs. 40 [30, 50] mmHg, p < 0.001; 9 [6, 12] mmHg vs. 4 [2, 7] mmHg, p < 0.001) Pre-procedural MGs correlated better than post-procedural MGs (r = 0.70, p < 0.001 vs. r = 0.23, p < 0.001), particularly in self-expandable valves and smaller sinus of Valsalva diameter (SOVd) (r = 0.33, p < 0.001; r = 0.46, p < 0.001 vs R = 0.06, p = 0.701). Non-invasive MG remained stable from discharge (9 [6, 12] mmHg) to 5 years (9 [7, 12] mmHg). While structural valve deterioration and patient-prosthesis mismatch showed no impact, extreme invasive MGs (< 3 or > 6 mmHg) predicted worse outcomes (mortality hazard: 1.25 [1.06, 1.88] and 0.85 [0.8, 0.95], respectively), unlike non-invasive measurements. In conclusion, invasive as compared with non-invasive MGs correlated better before than after valve implantation, whereas invasive MGs were always lower than non-invasive MGs. Lower invasive MGs after TAVI appeared to be associated with favourable long-term outcomes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cardiovascular Intervention and Therapeutics
Cardiovascular Intervention and Therapeutics CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
6.30
自引率
12.50%
发文量
68
期刊介绍: Cardiovascular Intervention and Therapeutics (CVIT) is an international journal covering the field of cardiovascular disease and includes cardiac (coronary and noncoronary) and peripheral interventions and therapeutics. Articles are subject to peer review and complete editorial evaluation prior to any decision regarding acceptability. CVIT is an official journal of The Japanese Association of Cardiovascular Intervention and Therapeutics.
期刊最新文献
Self-made fenestrated device for closure of atrial septal defect. Calcium channel blocker use and outcomes following transcatheter aortic valve intervention for aortic stenosis. Deep dive into intravascular coronary imaging in calcified lesions. Sex-related outcomes after percutaneous coronary intervention of in-stent restenosis. Cerebral air embolism after accidental air injection into a radial artery sheath.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1