通过比较毛细管血和静脉血及测定硫酸铜溶液的稳定性来优化滴下血红蛋白法。

IF 1.3 Q4 HEMATOLOGY Journal of hematology Pub Date : 2024-12-01 Epub Date: 2024-12-02 DOI:10.14740/jh1337
Amogh Chariyamane, Tim R Randolph
{"title":"通过比较毛细管血和静脉血及测定硫酸铜溶液的稳定性来优化滴下血红蛋白法。","authors":"Amogh Chariyamane, Tim R Randolph","doi":"10.14740/jh1337","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Anemia is a global health issue that affects over 1 billion people and contributes to maternal mortality and birth defects. Low-resource, tropical areas face a dual challenge: high prevalence of anemia and inability to access affordable testing methods. The falling drop hemoglobin method has been developed by our lab to quantify hemoglobin concentration and assess anemia by timing the descent of venous blood in a column of copper sulfate solution, without using electricity or batteries. This research aimed to optimize the falling drop hemoglobin method by evaluating the use of capillary blood to reduce within sample variance and assessing copper sulfate stability to determine shelf life in expected working conditions.</p><p><strong>Methods: </strong>The falling drop hemoglobin method was performed on both venous and capillary blood samples collected directly from the fingertip by dispensing 44 µL of blood in a copper sulfate column. A microhematocrit was performed on the venous blood sample and converted mathematically to a hemoglobin level to serve as the standard. Copper sulfate stability was assessed for 32 weeks among three solutions: solution prepared fresh on day of testing, solution incubated at room temperature, and solution incubated at 37.7 °C.</p><p><strong>Results: </strong>Capillary blood yielded higher average descent times and higher standard deviations than venous blood. Collecting precisely 44 µL of capillary blood proved challenging and impractical. In copper sulfate stability testing, freshly prepared solution yielded the highest average descent time. A one-way analysis of variance (ANOVA) test and Tukey's honestly significant difference (HSD) post hoc testing revealed no significant difference between mean descent times of freshly prepared and 37.7 °C solutions (P = 0.26) and between room temperature and 37.7 °C solutions (P = 0.64), but a significant difference between freshly prepared and room temperature solutions (P = 0.04).</p><p><strong>Conclusions: </strong>This study found that capillary blood did not present a more accurate alternative to venous blood in the falling drop hemoglobin test, and copper sulfate did not degrade over 32 weeks at 37.7 °C. This lends support for the current use of venous blood in the test, and for use of copper sulfate solution in tropical climates, where the test is most necessary, with a shelf life of at least 32 weeks.</p>","PeriodicalId":15964,"journal":{"name":"Journal of hematology","volume":"13 6","pages":"261-267"},"PeriodicalIF":1.3000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11650553/pdf/","citationCount":"0","resultStr":"{\"title\":\"Optimizing Falling Drop Hemoglobin Method by Comparing Capillary Versus Venous Blood and Determining the Stability of the Copper Sulfate Solution.\",\"authors\":\"Amogh Chariyamane, Tim R Randolph\",\"doi\":\"10.14740/jh1337\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Anemia is a global health issue that affects over 1 billion people and contributes to maternal mortality and birth defects. Low-resource, tropical areas face a dual challenge: high prevalence of anemia and inability to access affordable testing methods. The falling drop hemoglobin method has been developed by our lab to quantify hemoglobin concentration and assess anemia by timing the descent of venous blood in a column of copper sulfate solution, without using electricity or batteries. This research aimed to optimize the falling drop hemoglobin method by evaluating the use of capillary blood to reduce within sample variance and assessing copper sulfate stability to determine shelf life in expected working conditions.</p><p><strong>Methods: </strong>The falling drop hemoglobin method was performed on both venous and capillary blood samples collected directly from the fingertip by dispensing 44 µL of blood in a copper sulfate column. A microhematocrit was performed on the venous blood sample and converted mathematically to a hemoglobin level to serve as the standard. Copper sulfate stability was assessed for 32 weeks among three solutions: solution prepared fresh on day of testing, solution incubated at room temperature, and solution incubated at 37.7 °C.</p><p><strong>Results: </strong>Capillary blood yielded higher average descent times and higher standard deviations than venous blood. Collecting precisely 44 µL of capillary blood proved challenging and impractical. In copper sulfate stability testing, freshly prepared solution yielded the highest average descent time. A one-way analysis of variance (ANOVA) test and Tukey's honestly significant difference (HSD) post hoc testing revealed no significant difference between mean descent times of freshly prepared and 37.7 °C solutions (P = 0.26) and between room temperature and 37.7 °C solutions (P = 0.64), but a significant difference between freshly prepared and room temperature solutions (P = 0.04).</p><p><strong>Conclusions: </strong>This study found that capillary blood did not present a more accurate alternative to venous blood in the falling drop hemoglobin test, and copper sulfate did not degrade over 32 weeks at 37.7 °C. This lends support for the current use of venous blood in the test, and for use of copper sulfate solution in tropical climates, where the test is most necessary, with a shelf life of at least 32 weeks.</p>\",\"PeriodicalId\":15964,\"journal\":{\"name\":\"Journal of hematology\",\"volume\":\"13 6\",\"pages\":\"261-267\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11650553/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of hematology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14740/jh1337\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/2 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of hematology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14740/jh1337","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/2 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:贫血是一个全球性的健康问题,影响着超过10亿人,并导致孕产妇死亡和出生缺陷。资源匮乏的热带地区面临着双重挑战:贫血的高患病率和无法获得负担得起的检测方法。下落血红蛋白法是由我们的实验室开发的,通过测定硫酸铜溶液柱中静脉血下降的时间来定量血红蛋白浓度并评估贫血,而不使用电力或电池。本研究旨在通过评估毛细管血的使用减少样本内方差和评估硫酸铜的稳定性来确定预期工作条件下的保质期,从而优化滴落血红蛋白法。方法:直接采集指尖静脉血和毛细血管血,采用滴血血红蛋白法,用硫酸铜柱配血44µL。在静脉血样本上进行微血细胞比容,并将其数学转换为血红蛋白水平作为标准。在测试当天新鲜制备的溶液、室温孵育的溶液和37.7℃孵育的溶液中,评估硫酸铜32周的稳定性。结果:与静脉血相比,毛细血管血平均下降时间更长,标准差更高。事实证明,精确采集44 μ L的毛细血管血液具有挑战性且不切实际。在硫酸铜稳定性试验中,新鲜配制的溶液平均下降时间最长。单因素方差分析(ANOVA)检验和Tukey诚实显著性差异(HSD)事后检验显示,新鲜制备的溶液与37.7°C溶液的平均下降时间无显著差异(P = 0.26),室温溶液与37.7°C溶液的平均下降时间无显著差异(P = 0.64),新鲜制备的溶液与室温溶液的平均下降时间有显著差异(P = 0.04)。结论:本研究发现,滴落血红蛋白试验中毛细血管血并没有比静脉血更准确的替代方法,在37.7℃下,硫酸铜在32周内没有降解。这为目前测试中使用静脉血提供了支持,也为在热带气候下使用硫酸铜溶液提供了支持,在热带气候下,测试是最必要的,其保质期至少为32周。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimizing Falling Drop Hemoglobin Method by Comparing Capillary Versus Venous Blood and Determining the Stability of the Copper Sulfate Solution.

Background: Anemia is a global health issue that affects over 1 billion people and contributes to maternal mortality and birth defects. Low-resource, tropical areas face a dual challenge: high prevalence of anemia and inability to access affordable testing methods. The falling drop hemoglobin method has been developed by our lab to quantify hemoglobin concentration and assess anemia by timing the descent of venous blood in a column of copper sulfate solution, without using electricity or batteries. This research aimed to optimize the falling drop hemoglobin method by evaluating the use of capillary blood to reduce within sample variance and assessing copper sulfate stability to determine shelf life in expected working conditions.

Methods: The falling drop hemoglobin method was performed on both venous and capillary blood samples collected directly from the fingertip by dispensing 44 µL of blood in a copper sulfate column. A microhematocrit was performed on the venous blood sample and converted mathematically to a hemoglobin level to serve as the standard. Copper sulfate stability was assessed for 32 weeks among three solutions: solution prepared fresh on day of testing, solution incubated at room temperature, and solution incubated at 37.7 °C.

Results: Capillary blood yielded higher average descent times and higher standard deviations than venous blood. Collecting precisely 44 µL of capillary blood proved challenging and impractical. In copper sulfate stability testing, freshly prepared solution yielded the highest average descent time. A one-way analysis of variance (ANOVA) test and Tukey's honestly significant difference (HSD) post hoc testing revealed no significant difference between mean descent times of freshly prepared and 37.7 °C solutions (P = 0.26) and between room temperature and 37.7 °C solutions (P = 0.64), but a significant difference between freshly prepared and room temperature solutions (P = 0.04).

Conclusions: This study found that capillary blood did not present a more accurate alternative to venous blood in the falling drop hemoglobin test, and copper sulfate did not degrade over 32 weeks at 37.7 °C. This lends support for the current use of venous blood in the test, and for use of copper sulfate solution in tropical climates, where the test is most necessary, with a shelf life of at least 32 weeks.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of hematology
Journal of hematology HEMATOLOGY-
自引率
0.00%
发文量
29
期刊最新文献
A Case of Fulminant Cerebral Edema Leading to Death After Chimeric Antigen Receptor T-Cell Therapy. Methionine Synthase Reductase A66G Variant in Pediatric Acute Lymphoblastic Leukemia Patients. Optimizing Falling Drop Hemoglobin Method by Comparing Capillary Versus Venous Blood and Determining the Stability of the Copper Sulfate Solution. Retrospective Study of CD20 Expression Loss in Relapsed or Refractory B-Cell Non-Hodgkin Lymphoma. Sequential Use of Prednisolone and Cyclosporine Is Effective in the Management of Immunotherapy-Related Hemolytic Anemia.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1