{"title":"【高效液相色谱法在食品器具、容器和包装中己内酰胺迁移检测中的应用】","authors":"Yutaka Abe, Miku Yamaguchi, Koji Fujihara, Yohei Kataoka, Motoh Mutsuga, Naoki Sugimoto","doi":"10.3358/shokueishi.65.107","DOIUrl":null,"url":null,"abstract":"<p><p>We assessed the applicability of high-performance liquid chromatography (HPLC) to the official testing method for the migration of caprolactam (CPL) from food utensils, containers, and packaging made from polyamide (PA). Hydrophilic interaction chromatography (HILIC) columns coated with unmodified silica, carbamoyl, and aminopropyl were used. Water and acetonitrile (ACN) were used as the mobile phase, and the analytical conditions were optimized. The test solution was diluted 10-fold with ACN, and standard solutions were prepared using 98% ACN. We validated using HPLC as limit testing and quantitative testing methods. Accuracy parameters corresponding to trueness, repeatability, and reproducibility (as intermediate precision) satisfied the target values in both cases, indicating that this method demonstrates good performance as a testing method.</p>","PeriodicalId":54373,"journal":{"name":"Food Hygiene and Safety Science","volume":"65 5","pages":"107-112"},"PeriodicalIF":0.2000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Application of High-performance Liquid Chromatography to Caprolactam Migration Testing of Food Utensils, Containers, and Packaging].\",\"authors\":\"Yutaka Abe, Miku Yamaguchi, Koji Fujihara, Yohei Kataoka, Motoh Mutsuga, Naoki Sugimoto\",\"doi\":\"10.3358/shokueishi.65.107\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We assessed the applicability of high-performance liquid chromatography (HPLC) to the official testing method for the migration of caprolactam (CPL) from food utensils, containers, and packaging made from polyamide (PA). Hydrophilic interaction chromatography (HILIC) columns coated with unmodified silica, carbamoyl, and aminopropyl were used. Water and acetonitrile (ACN) were used as the mobile phase, and the analytical conditions were optimized. The test solution was diluted 10-fold with ACN, and standard solutions were prepared using 98% ACN. We validated using HPLC as limit testing and quantitative testing methods. Accuracy parameters corresponding to trueness, repeatability, and reproducibility (as intermediate precision) satisfied the target values in both cases, indicating that this method demonstrates good performance as a testing method.</p>\",\"PeriodicalId\":54373,\"journal\":{\"name\":\"Food Hygiene and Safety Science\",\"volume\":\"65 5\",\"pages\":\"107-112\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Food Hygiene and Safety Science\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.3358/shokueishi.65.107\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"FOOD SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Hygiene and Safety Science","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.3358/shokueishi.65.107","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"FOOD SCIENCE & TECHNOLOGY","Score":null,"Total":0}
[Application of High-performance Liquid Chromatography to Caprolactam Migration Testing of Food Utensils, Containers, and Packaging].
We assessed the applicability of high-performance liquid chromatography (HPLC) to the official testing method for the migration of caprolactam (CPL) from food utensils, containers, and packaging made from polyamide (PA). Hydrophilic interaction chromatography (HILIC) columns coated with unmodified silica, carbamoyl, and aminopropyl were used. Water and acetonitrile (ACN) were used as the mobile phase, and the analytical conditions were optimized. The test solution was diluted 10-fold with ACN, and standard solutions were prepared using 98% ACN. We validated using HPLC as limit testing and quantitative testing methods. Accuracy parameters corresponding to trueness, repeatability, and reproducibility (as intermediate precision) satisfied the target values in both cases, indicating that this method demonstrates good performance as a testing method.